Ilaria Chirichilli

Ilaria Chirichilli

Auto-generated profile, based on publicly available information

Ilaria Chirichilli

Department of Cardiac Surgery and Heart Transplantation, San Camillo Forlanini Hospital , Rome, 00152

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2024 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
Francesco PollariFrancesco Pollari
Francesco Pollari
PNPaolo Nardi
Paolo Nardi
EMElisa Mikus
Elisa Mikus
FFFrancesco Ferraro
Francesco Ferraro
MGMarco Gemelli
Marco Gemelli
FRFrancesco Rosato
Francesco Rosato
In last decades, 4 different scores for prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. We retrospectively analyzed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centers from 2 European countries. Outcomes were the early (30-days and/or in-hospital), and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. 30-days and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The GERAADA score shows to have the best discrimination (AUC 0.671 and 0.672) in predicting as well the early and the 1-year mortality, followed by the IRAD Model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK-Aortic Score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD Model I and GERAADA respectively were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK Aortic Score and IRAD Model I for both outcomes. The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.

29 December 2022 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
ICIlaria Chirichilli
Ilaria Chirichilli
RSRaffaele Scaffa
Raffaele Scaffa
FIFrancesco Giosuè Irace
Francesco Giosuè Irace
ASAndrea Salica
Andrea Salica
LWLuca Paolo Weltert
Luca Paolo Weltert
RPRuggero De Paulis
Ruggero De Paulis
OBJECTIVES: Over the past 20 years, valve-sparing aortic root replacement has aroused increasing interest because of a progressive attitude towards the preservation of natural tissue. Aortic reimplantation is the most used technique to spare the valve, allowing simultaneously aortic root replacement and aortic annular stabilization. The reimplantation into a graft with sinuses guarantees an optimal anatomic and functional reconstruction with established good results at 15 years. The aim of this study is to report the world longest follow-up (up to 20 years) of aortic valve reimplantation using the Valsalva graft.METHODS: From February 2000 to December 2021, 265 consecutive patients with aortic root aneurysm received aortic valve reimplantation using the Valsalva graft. From 2018, leaflet plication with the routine use of calliper was performed. For each patient, we performed both intraoperative and post-procedural transoesophageal echocardiography. All patients were followed with clinical assessment and echocardiography. The mean duration of follow-up was 85 ± 63 months.RESULTS: The study cohort had a median age of 55 ± 18 and 87.2% were male. The aortic root aneurysm was associated to bicuspid aortic valve in 18.9% of patients and to Marfan syndrome in 10.6% of cases. 55.9% had an aortic regurgitation ≥ 2+. Overall survival at 15 was 87.6 ± 3.4. Freedom from cardiac death was stable at 99.6 ± 0.4 at 5, 10 and 15 years. Freedom from recurrent AR ≥3+ and freedom from reoperation remained stable at 10 and 15 years at 92.2 ± 2.1 and 95.9 ± 1.6, respectively. There was a minimal incidence of infective endocarditis (0.8%), thromboembolism (2.2%) and haemorrhage (2.0%). Six out of 7 patients requiring reoperation had surgery in the first period of our experience (last in 2004). Early suboptimal results had a negative effect on residual aortic regurgitation. Moreover, we hypothesized that the routine use of calliper may have contributed to a further improvement of the outcome, even if these data need to be confirmed by a longer follow-up.CONCLUSIONS: The first long-term follow-up after aortic valve reimplantation using the Valsalva graft demonstrated excellent results. These long-term results gradually improved with learning curve, remaining stable during the second decade of observation. The systematic use of calliper may have contributed to a further improvement of the outcome.

1 May 2008 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
FBFederico Bizzarri
Federico Bizzarri
CMConsalvo Mattia
Consalvo Mattia
MRMassimo Ricci
Massimo Ricci
ICIlaria Chirichilli
Ilaria Chirichilli
CSChiara Santo
Chiara Santo
ALAndrea Laghi
Andrea Laghi
This article details a case report of a traumatic aortic arch false aneurysm after blunt chest trauma. Thoracic aorta false aneurysms are a rare and life-threatening complication of aortic surgery, infection, genetic disorders and trauma.

24 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FIFrancesco Giosuè Irace
Francesco Giosuè Irace
ICIlaria Chirichilli
Ilaria Chirichilli
MRMarco Russo
Marco Russo
FRFederico Ranocchi
Federico Ranocchi
MBMarcello Bergonzini
Marcello Bergonzini
FMFrancesco Musumeci
Francesco Musumeci
Introduction. The most common minimally invasive approach for aortic valve replacement (AVR) is the partial upper mini-sternotomy. The aim of this study is to understand which preoperative computed tomography (CT) features are predictive of longer operations in terms of cardio-pulmonary bypass timesand cross-clamp times. Methods. From 2011 to 2022, we retrospectively selected 246 patients which underwent isolated AVR and had a preoperative ECG-gated CT scan. On these patients, we analysed the baseline anthropometric characteristics and the following CT scan parameters: aortic annular dimensions, valve calcium score, ascending aorta length, ascending aorta inclination and aorta–sternum distance. Results. We identified augmented body surface area (>1.9 m2), augmented annular diameter (>23 mm), high calcium score (>2500 Agatson score) and increased aorta–sternum distance (>30 mm) as independent predictors of elongated operation times (more than two-fold). Conclusions. Identifying the preoperative predictive factors of longer operations can help surgeons select cases suitable for minimally invasive approaches, especially in a teaching context.

4 July 2012 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
DRDavid Rose
David Rose
RDRiccardo D'Ascoli
Riccardo D'Ascoli
ICIlaria Chirichilli
Ilaria Chirichilli
Antonino GM MarulloAntonino GM Marullo
Antonino GM Marullo
MTMichele Toscano
Michele Toscano
FMFabio Miraldi
Fabio Miraldi
MitraClip system has been recently introduced in clinical practice for percutaneous mitral valve repair in selected patients. In the case of early or late detachment of the device dedicated tools, either with percutaneous or surgical approach, have been developed. We describe a novel technique to atraumatically remove the MitraClip. (J Card Surg 2012;27:543‐545)

1 January 2022 in Seminars in Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
PDF file
ICIlaria Chirichilli
Ilaria Chirichilli
FIFrancesco Giosuè Irace
Francesco Giosuè Irace
ASAndrea Salica
Andrea Salica
SDSalvatore D'ALeo
Salvatore D'ALeo
LWLorenzo Guerrieri Wolf
Lorenzo Guerrieri Wolf
RPRuggero De Paulis
Ruggero De Paulis