Representative Publications

View All Publications
28 May 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TLTongkun Lan
Tongkun Lan
YLYinhong Li
Yinhong Li
XDXianzhong Duan
Xianzhong Duan
To deal with the high-resistance fault identification problem in multi-terminal VSC-HVDC, this paper proposes a high fault-resistance tolerable traveling wave protection. First, the non-unified characteristic of traveling wave front between internal and external faults is revealed, which makes the high-resistance fault identification difficult. Then, the traveling wave propagation regarding the reflection and refraction process at the remote end is investigated for the difference, and the distinctive current reduction phenomenon during the interval of two incident traveling waves under internal fault with resistance is discovered. Moreover, the current reduction phenomenon would become more significant with the increase of fault resistance. Based on this phenomenon, the high fault-resistance tolerable traveling wave protection is proposed, which could identify the high-resistance fault accurately with single-end measurement and is insensitive to fault resistance. The feasibility and robustness of the proposed protection are validated in a four-terminal VSC-HVDC.

14 August 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TLTongkun Lan
Tongkun Lan
HXHao Xiao
Hao Xiao
YLYinhong Li
Yinhong Li
JCJinfu Chen
Jinfu Chen
Benefiting to the immunization of distributed capacitance, Bergeron model based current differential protection has become a promising backup protection in HVDC grid. However, its performance strongly relies on the precise transmission line parameter, whereas the error of parameter is inevitable due to the frequency-dependent nature. To solve this problem, an enhanced current differential protection with parameter error tolerability is proposed in this paper. The influence of transmission line parameter error on the compensated current is investigated, where the parameter error is embodied by the characteristic impedance and velocity of traveling wave. It is discovered that the major influence comes from the error of traveling wave velocity. The main idea behind the proposed protection is to mitigate the influence from the perspective of velocity. Wavelet transform modulus maxima (WTMM) is adopted to locate and calibrate the arrival time of traveling wave. The differential current under external fault is reduced effectively, which could have been higher than that of the internal fault when the parameter error exists, thus avoiding the protection misoperation. Finally, the feasibility and robustness of the proposed protection are validated in a four-terminal VSC-HVDC grid.

21 January 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
TLTongkun Lan
Tongkun Lan
HXHao Xiao
Hao Xiao
YLYinhong Li
Yinhong Li
JCJinfu Chen
Jinfu Chen
For the transmission line fault in multiterminal voltage source converter (VSC) based high-voltage direct current (HVdc), the frequency spectrum of internal fault is obviously higher compared with the external fault. In frequency transient-based protection, the fault is generally identified by the high-frequency component via the professional mathematical algorithm, such as Fourier and wavelet transforms. However, the burdensome computation would slow down the protection operation speed, and the details in the specific frequencies are far beyond the need for fault identification. In this article, a computationally effective protection is proposed without utilizing the complicated mathematical algorithm. Comprehensive index given from the supplemental inductor is developed, which shows the greater value for higher frequency spectrum, and requires fewer algebraic operations. The proposed protection based on the comprehensive index is with superior computational efficiency and maintains the advantage of frequency transient-based protection in fault identification accuracy. The protection performance is validated in four/three-terminal VSC-HVdc.

5 January 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TLTongkun Lan
Tongkun Lan
SMS. Mahdi Mazhari
S. Mahdi Mazhari
HTHamid Teimourzadeh
Hamid Teimourzadeh
CCC. Y. Chung
C. Y. Chung
Precise permanent fault localization is an important task for fast power restoration in underground HV cable systems. Among online fault localization methods, the fault localization accuracy strongly relies on the type and volume of measurement, and there is always a tradeoff between localization accuracy and measurement cost. To balance the tradeoff, a data-efficient HV cable fault localization framework is proposed in this paper. First, the fault characteristics of sheath currents are analyzed in modal mode, and compared with the conventional core conductor measurements. It is discerned that the sum of three phases sheath currents has similar characteristics, which can be measured by fewer sensors in a lower rating as the replacement of the conventional core conductor measurements. Second, the challenges of recognizing the wavefront arrival in the sheath are presented, and a Convolution Neural Network is introduced for the localization purpose. The proposed approach can realize high localization accuracy with low-cost measurement, and keep consistent performance under various scenarios through limited training datasets. A case study has been carried out using PSCAD/EMTDC platform to validate the effectiveness and feasibility of the proposed approach, followed by a discussion on the results.

2 December 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HXHao Xiao
Hao Xiao
XDXianzhong Duan
Xianzhong Duan
YZYi Zhang
Yi Zhang
TLTongkun Lan
Tongkun Lan
YLYinhong Li
Yinhong Li
The strength has a large impact on the commutation failure (CF) in hybrid multi-infeed HVdc (HMIDC) systems including both voltage-source converters and line-commutated converters. However, this impact has always been quantified by the simulation-based method in earlier works, which is very time-consuming and cannot lend the exhaustively theoretical perspective. Thus, in this letter, the mathematical expression of the CF immunity index as the analytical function of the hybrid multi-infeed interactive effective short-circuit ratio strength index is first developed based on the quasi-steady-state model of HMIDC systems. Thereafter, the developed expression is used for analytically quantifying the impact of the strength on the CF in a much more efficient manner with more sufficiently theoretical perspective compared to the simulation-based method in earlier works. Finally, the theoretical developments are validated by the experimental results of the hardware-in-the-loop platform based on a hybrid six-infeed HVdc test system.

17 March 2025 in Electric Power Systems Research
Verified
Journal Article
Open access
MSMorteza Shamsoddini
Morteza Shamsoddini
TLTongkun Lan
Tongkun Lan
SKSeokbum Ko
Seokbum Ko
CCChi Yung Chung
Chi Yung Chung