Orsolya Hakkel

Dr. Orsolya Hakkel


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
ZSZoltán Szabó
Zoltán Szabó
KPKitti Pankász
Kitti Pankász
JBJános Márk Bozorádi
János Márk Bozorádi
OHOrsolya Hakkel
Orsolya Hakkel
SBSzabolcs Bella
Szabolcs Bella
PFPéter Fürjes
Péter Fürjes
We intend to develop an in situ near-infrared spectroscopic solution for monitoring the nutrient composition (e.g., lactate concentration) in microfluidic channels of organ-on-chip devices. In this work, the effects of the geometry, surface quality, and architecture of the micro-volume cuvettes were characterized and optimized considering the signal-to-noise ratio and sensitivity of the proposed spectroscopic method in case of aqueous solutions. The applicability of the micro-volume near-infrared spectroscopy method using this specially designed microfluidic cuvette was proven.

3 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ZSZsombor Szomor
Zsombor Szomor
LBLilia Bató
Lilia Bató
OHOrsolya Hakkel
Orsolya Hakkel
CDCsaba Dücső
Csaba Dücső
ZBZsófia Baji
Zsófia Baji
PFPéter Fürjes
Péter Fürjes
A compact electrochemical sensor module for pH detection was developed for potential integration into specialized devices used for live cell or tissue incubation, for applications in highly parallelized cell culture analysis, by incorporating Organ-on-Chip devices. This research focuses on the deposition, structural and chemical analysis, and functional characterization of different titanium-oxide layers with various compositions as potentially sensitive materials for pH sensing applications. The titanium-oxide layers were deposited using vacuum sputtering and atomic layer deposition at 100 °C and 300 °C, respectively. Transmission electron microscopy and X-ray photoelectron spectroscopy were utilized to determine the specific composition and structure of different titanium-oxide layers. These TiOx-functionalized electrodes were connected to the application-specific analog front-end chip of the low-power readout circuit for precise evaluation. The pH sensitivity of the differently modified electrodes, employing various TiOx materials, was evaluated using pH calibration solutions ranging from pH 6 to 8. Among the various deposition solutions, such as sputtering or high-temperature atomic layer deposition, the TiOx layer deposited using low-temperature atomic layer deposition proved more suitable for pH sensing applications, with a sensitivity of 54.8–56.7 mV/pH, which closely approximates the Nernstian response.