Lilia Bató

Ms. Lilia Bató

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LBLilia Bató
Lilia Bató
PFPéter Fürjes
Péter Fürjes
Electrochemical impedance spectroscopy (EIS) is a non-invasive and label-free method widely used for characterizing cell cultures and monitoring their structure, behavior, proliferation and viability. Microfluidic systems are often used in combination with EIS methods utilizing small dimensions, controllable physicochemical microenvironments and offering rapid real-time measurements. In this work, an electrode array capable of conducting EIS measurements was integrated into a multichannel microfluidic chip which is able to trap individual cells or cell populations in specially designed channels comparable to the size of cells. An application-specific printed circuit board (PCB) was designed for the implementation of the impedance measurement in order to facilitate connection with the device used for taking EIS spectra and for selecting the channels to be measured. The PCB was designed in consideration of the optical screening of trapped cells in parallel with the EIS measurements which allows the comparison of EIS data with optical signals. With continuous EIS measurement, the filling of channels with cell suspension can be followed. Yeast cells were trapped in the microfluidic system and EIS spectra were recorded considering each individual channel, which allows differentiating between the number of trapped cells.

1 October 2024 in Heliyon
Verified
Journal Article
Open access
BBBarbara Beiler
Barbara Beiler
ÁSÁgnes Sáfrány
Ágnes Sáfrány
LBLilia Bató
Lilia Bató
ZSZsombor Szomor
Zsombor Szomor
MVMiklos Veres
Miklos Veres
Gamma-radiation initiated polymerization is an easy-to-use and simple technique for the preparation of porous polymer monoliths widely used as active materials in separation columns. Herein, binary porogen mixtures of ethyl acetate/acetone/acetonitrile with methanol were used to synthesize diethylene glycol dimethacrylate monoliths with this technique. Systematic studies have been performed to determine the effect of the composition of the solvent mixture on the morphology and the reaction kinetics, including the growth mechanism and the growth rate. The irradiation dose-dependent conversion profiles showed that with binary solvents the polymerization is much faster than with the same compounds used as single solvents. Depending on the type and the composition of the solvent one-, two- and three-dimensional, and fractal growth mechanisms were identified.

16 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LBLilia Bató
Lilia Bató
PFPéter Fürjes
Péter Fürjes
JBJános Márk Bozorádi
János Márk Bozorádi
Vladimir TadicVladimir Tadic
Vladimir Tadic
Peter OdryPeter Odry
Peter Odry
Zoltan VizvariZoltan Vizvari
Zoltan Vizvari
Electrical impedance measurements are traditionally macroscopic screening techniques designed to obtain information about the macroscopic internal structure of biological systems. In order to overcome the limitations that the technology detects, mainly with the bulk properties, a miniaturization is employed by developing a complex microfluidic system to achieve cell-scale information. In this work, a microelectrode array was incorporated into a microfluidic chip, allowing localized Electrochemical Impedance Spectroscopy (EIS) measurements, providing impedance data obtained in the spatial and frequency domains simultaneously. The height of the capillary in the microfluidic system was also systematically modified; hence, three types of channels with heights of 10 μm, 30 μm, and 50 μm were developed and studied. The EIS data collection was implemented using two different strategies (two- and four-electrode techniques). Sensitivity analysis was conducted using a microbead solution, where the linear mapping of the number of microbeads along the channel was achieved by EIS. Based on the findings, a complete overview of each measurement implementation was obtained, which is well explained by the physical background presented in the paper. In the case where the capillary height (10 μm) is comparable to the diameter of the microbeads (6 μm), the four-electrode technique detected the beads in a wider frequency range (approximately between 500 Hz and 50 kHz), while the two-electrode technique detected the beads in a narrower frequency range (approximately between 30 kHz and 300 kHz) with correlation greater than 0.9. In all other cases, a medium (or weak) correlation was found between the impedance data and the longitudinal bead distribution. Based on the results, the technology is ready for further development and adaptation for cell culture purposes.

3 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ZSZsombor Szomor
Zsombor Szomor
LBLilia Bató
Lilia Bató
OHOrsolya Hakkel
Orsolya Hakkel
CDCsaba Dücső
Csaba Dücső
ZBZsófia Baji
Zsófia Baji
PFPéter Fürjes
Péter Fürjes
A compact electrochemical sensor module for pH detection was developed for potential integration into specialized devices used for live cell or tissue incubation, for applications in highly parallelized cell culture analysis, by incorporating Organ-on-Chip devices. This research focuses on the deposition, structural and chemical analysis, and functional characterization of different titanium-oxide layers with various compositions as potentially sensitive materials for pH sensing applications. The titanium-oxide layers were deposited using vacuum sputtering and atomic layer deposition at 100 °C and 300 °C, respectively. Transmission electron microscopy and X-ray photoelectron spectroscopy were utilized to determine the specific composition and structure of different titanium-oxide layers. These TiOx-functionalized electrodes were connected to the application-specific analog front-end chip of the low-power readout circuit for precise evaluation. The pH sensitivity of the differently modified electrodes, employing various TiOx materials, was evaluated using pH calibration solutions ranging from pH 6 to 8. Among the various deposition solutions, such as sputtering or high-temperature atomic layer deposition, the TiOx layer deposited using low-temperature atomic layer deposition proved more suitable for pH sensing applications, with a sensitivity of 54.8–56.7 mV/pH, which closely approximates the Nernstian response.

29 July 2024 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
LBLilia Bató
Lilia Bató
PFPéter Fürjes
Péter Fürjes

1 January 2024
Verified
Conference Paper
Open access
PDF file
LBLilia Bató
Lilia Bató
JBJ. M. Bozorádi
J. M. Bozorádi
PFP. Fürjes
P. Fürjes
ZVZ. Vizvári
Z. Vizvári
In this work a microfluidic device was created with nanostructured integrated platinum electrodes to enhance the sensitivity of Electrochemical Impedance Spectroscopy (EIS) in cell analytical applications. The sensing microelectrodes were structured using Focused Ion Beam milling creating two separate electrodes with gap sizes ranging from 200 nm to 1 μm. The decreased electrode distance allows improved sensitivity in EIS measurements, especially when a micrometer size particle or cell is trapped between the electrodes. The electrode design is supported by finite element modelling of the evolving electromagnetic field in the microfluidic channel.