Seng Boh Lim

Dr. Seng Boh Lim

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SLSeng Boh Lim
Seng Boh Lim
PSPaola Godoy Scripes
Paola Godoy Scripes
MNMary Napolitano
Mary Napolitano
ESErgys Subashi
Ergys Subashi
NTNeelam Tyagi
Neelam Tyagi
DLDale Michael Lovelock
Dale Michael Lovelock
Objective: Adaptive radiation therapy (ART) is an integral part of MR‐guided RT (MRgRT), requiring a new RT plan for each treatment fraction and resulting in a significant increase in patient‐specific quality assurance (PSQA). This study investigates the possibility of using treatment log‐file for automated PSQA.Method: All treatment plans were delivered in 1.5T Unity MR‐Linac (Elekta). A Unity compatible version of LinacView (Standard Imaging) was commissioned to automatically monitor and analyze the log‐files. A total of 220 fields were delivered and measured by ArcCheck®‐MR (Sun Nuclear) and LinacView. Thirty incorrectly matched fields were also delivered to check for error detection sensitivity. The gamma analysis, γ, with 3%, 3 mm criteria was used in both ArcCheck®‐MR and LinacView. Additionally, the gantry angle, jaws, and multileaf collimators (MLC) positions reported in the log‐file were compared with plan positions using TG‐142 criteria.Result: The γ (3%, 3 mm) for the 190 plans were found to be between the range of 72.5%–100.0% and 95.4%–100.0% for ArcCheck®‐MR and LinacVeiw, respectively. All the delivered gantry angle and jaws were found to be within 0.2° and 2 mm. MLCs that were outside the guard leaves or under the diaphragms were found to have more than 1.0 mm discrepancy. This was attributed to the linac internal override for these MLCs and had no dosimetric impact. Excluding these discrepancies, all MLC positions were found to be within 1.0 mm. The γ (3%, 3 mm) for the 30 incorrectly matched fields were found to be 3.9%–84.8% and 0.1%–64.4% for ArcCheck®‐MR and LinacVeiw, respectively.Conclusion: Significant ranked correlation demonstrates the automated log‐file analysis can be used for PSQA and expedite the ART workflow. Ongoing PSQA will be compared with log‐file analysis to investigate the longer term reproducibility and correlation.

10 August 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
SLSeng Boh Lim
Seng Boh Lim
LKLiCheng Kuo
LiCheng Kuo
TLTianfang Li
Tianfang Li
XLXiang Li
Xiang Li
ABAse M. Ballangrud
Ase M. Ballangrud
MCMaria F. Chan
Maria F. Chan
Purpose: End‐to‐end testing (E2E) is a necessary process for assessing the readiness of the stereotactic radiosurgery (SRS) program and annual QA of an SRS system according to the AAPM MPPG 9a. This study investigates the differences between using a new SRS MapCHECK (SRSMC) system and an anthropomorphic phantom film‐based system in a large network with different SRS delivery techniques.Methods and materials: Three SRS capable Linacs (Varian Medical Systems, Palo Alto, CA) at three different regional sites were chosen to represent a hospital network, a Trilogy with an M120 multi‐leaf collimator (MLC), a TrueBeam with an M120 MLC, and a TrueBeam Stx with an HD120 MLC. An anthropomorphic STEEV phantom (CIRS, Norfolk, VA) and a phantom/diode array: StereoPHAN/SRSMC (Sun Nuclear, Melbourne, FL) were CT scanned at each site. The new STV‐PHANTOM EBT‐XD films (Ashland, Bridgewater, NJ) were used. Six plans with various complexities were measured with both films and SRSMC in the StereoPHAN to establish their dosimetric correlations. Three SRS cranial plans with a total of sixteen fields using dynamic conformal arc and volumetric‐modulated arc therapy, with 1–4 targets, were planned with Eclipse v15.5 treatment planning system (TPS) using a custom SRS beam model for each machine. The dosimetric and localization accuracy were compared. The time of analysis for the two systems by three teams of physicists was also compared to assess the throughput efficiency.Results: The correlations between films and SRSMC were found to be 0.84 (p = 0.03) and 0.16 (p = 0.76) for γ (3%, 1 mm) and γ (3%, 2 mm), respectively. With film, the local dose differences (ΔD) relative to the average dose within the 50% isodose line from the three sites were found to be −3.2%–3.7%. The maximum localization errors (Elocal) were found to be within 0.5 ± 0.2 mm. With SRSMC, the ΔD was found to be within 5% of the TPS calculation. Elocal were found to be within 0.7 to 1.1 ± 0.4 mm for TrueBeam and Trilogy, respectively. Comparing with film, an additional uncertainty of 0.7 mm was found with SRSMC. The delivery and analysis times were found to be 6 and 2 h for film and SRSMC, respectively.Conclusions: The SRS MapCHECK agrees dosimetrically with the films within measurement uncertainties. However, film dosimetry shows superior sub‐millimeter localization resolving power for the MPPG 9a implementation.

29 March 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
LZLei Zhang
Lei Zhang
SVSarath Vijayan
Sarath Vijayan
SHSheng Huang
Sheng Huang
YSYulin Song
Yulin Song
TLTianfang Li
Tianfang Li
Guang LiGuang Li
Guang Li
Purpose: This study aimed to evaluate and compare different system calibration methods from a large cohort of systems to establish a commissioning procedure for surface‐guided frameless cranial stereotactic radiosurgery (SRS) with intrafractional motion monitoring and gating. Using optical surface imaging (OSI) to guide non‐coplanar SRS treatments, the determination of OSI couch‐angle dependency, baseline drift, and gated‐delivered‐dose equivalency are essential.Methods: Eleven trained physicists evaluated 17 OSI systems at nine clinical centers within our institution. Three calibration methods were examined, including 1‐level (2D), 2‐level plate (3D) calibration for both surface image reconstruction and isocenter determination, and cube phantom calibration to assess OSI‐megavoltage (MV) isocenter concordance. After each calibration, a couch‐angle dependency error was measured as the maximum registration error within the couch rotation range. A head phantom was immobilized on the treatment couch and the isocenter was set in the middle of the brain, marked with the room lasers. An on‐site reference image was acquired at couch zero, the facial region of interest (ROI) was defined, and static verification images were captured every 10° for 0°–90° and 360°–270°. The baseline drift was assessed with real‐time monitoring of the motionless phantom over 20 min. The gated‐delivered‐dose equivalency was assessed using the electron portal imaging device and gamma test (1%/1mm) in reference to non‐gated delivery.Results: The maximum couch‐angle dependency error occurs in longitudinal and lateral directions and is reduced significantly (P < 0.05) from 1‐level (1.3 ± 0.4 mm) to 2‐level (0.8 ± 0.3 mm) calibration. The MV cube calibration does not further reduce the couch‐angle dependency error (0.8 ± 0.2 mm) on average. The baseline drift error plateaus at 0.3 ± 0.1 mm after 10 min. The gated‐delivered‐dose equivalency has a >98% gamma‐test passing rate.Conclusion: A commissioning method is recommended using the 3D plate calibration, which is verified by radiation isocenter and validated with couch‐angle dependency, baseline drift, and gated‐delivered‐dose equivalency tests. This method characterizes OSI uncertainties, ensuring motion‐monitoring accuracy for SRS treatments.

18 February 2022 in Physica Medica
Verified
Journal Article
Open access
SLSeng Boh Lim
Seng Boh Lim
NTNeelam Tyagi
Neelam Tyagi
ESErgys Subashi
Ergys Subashi
JLJiayi Liang
Jiayi Liang
MCMaria Chan
Maria Chan
The goal of this study was to evaluate the use of EBT-XD film for SRS/SBRT commissioning in a 1.5T hybrid MR-Linac (MRL). The output factors (St), from 1x1, 2x2, 3x3 cm2, were measured with film in solid water. The results were compared with (1) the measurements by a PTW diamond detector (CVD) and an Exradin® A26MR ion chamber in 3D water phantom; (2) Monte Carlo calculation by Monaco TPS (MTPS) in water. The inline (IN) and crossline (CR) profiles, measured by films and the CVD, were also compared. An SRS plan with two targets was created in MTPS and was measured with EBT-XD film in a StereoPHAN™ phantom serving as an end-to-end test. The 3x3 cm2 was used for film calibration with doses ranging from 0 to 28 Gy. Water was added to the phantom-film-phantom interface to reduce the electron-return-effect (ERE). Films were calibrated with One-scan-dosimetry protocol. The film St were within 1.2% and 2.2% compared to other detectors and MTPS respectively. At the central B-field induced asymmetric region, films were within 0.6% between the CVD and the MTPS, but 5–8% differences were observed in the 40%-5% gradient region in CR due to ERE. The differences in localization and dose were found to be 0.6 mm and 3.3%. The γ(3%/2mm), γ (5%/2mm), γ (5%/1mm) were 97.7%, 99.3%, 94.6%. Films can provide accurate dosimetric results under ERE and are valuable for commissioning MRL. Using the One-scan-dosimetry protocol with EBT-XD film for MRL increases accuracy and efficiency in commissioning and QA of SRS/SBRT.

26 February 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SLSeng Boh Lim
Seng Boh Lim
BZBenjamin J. Zwan
Benjamin J. Zwan
DLDanny Lee
Danny Lee
PGPeter Greer
Peter Greer
DLDale Michael Lovelock
Dale Michael Lovelock
The use of trajectory log files for routine patient quality assurance is gaining acceptance. Such use requires the validation of the trajectory log itself. However, the accurate localization of a multileaf collimator (MLC) leaf while it is in motion remains a challenging task. We propose an efficient phantom‐less technique using the EPID to verify the dynamic MLC positions with high accuracy. Measurements were made on four Varian TrueBeams equipped with M120 MLCs. Two machines were equipped with the S1000 EPID; two were equipped with the S1200 EPID. All EPIDs were geometrically corrected prior to measurements. Dosimetry mode EPID measurements were captured by a frame grabber card directly linked to the linac. All leaf position measurements were corrected both temporally and geometrically. The readout latency of each panel, as a function of pixel row, was determined using a 40 × 1.0 cm2 sliding window (SW) field moving at 2.5 cm/s orthogonal to the row readout direction. The latency of each panel type was determined by averaging the results of two panels of the same type. Geometric correction was achieved by computing leaf positions with respect to the projected isocenter position as a function of gantry angle. This was determined by averaging the central axis position of fields at two collimator positions of 90° and 270°. The radiological to physical leaf end position was determined by comparison of the measured gap with that determined using a feeler gauge. The radiological to physical leaf position difference was found to be 0.1 mm. With geometric and latency correction, the proposed method was found to be improve the ability to detect dynamic MLC positions from 1.0 to 0.2 mm for all leaves. Latency and panel residual geometric error correction improve EPID‐based MLC position measurement. These improvements provide for the first time a trajectory log QA procedure.

1 January 2019 in Technology in Cancer Research & Treatment
Verified
Journal Article
Open access
PDF file
SLSeng Boh Lim
Seng Boh Lim
CTC. J. Tsai
C. J. Tsai
YYY. Yu
Y. Yu
PGP. Greer
P. Greer
TFT. Fuangrod
T. Fuangrod
DLD. M. Lovelock
D. M. Lovelock
In adaptive radiation therapy of head and neck cancer, any significant anatomical changes observed are used to adapt the treatment plan to maintain target coverage without elevating the risk of xerostomia. However, the additional resources required for adaptive radiation therapy pose a challenge for broad-based implementation. It is hypothesized that a change in transit fluence is associated with volumetric change in the vicinity of the target and therefore can be used as a decision support metric for adaptive radiation therapy. This was evaluated by comparing the fluence with volumetric changes in 12 patients. Transit fluence was measured by an in vivo portal dosimetry system. Weekly cone beam computed tomography was used to determine volume change in the rectangular region of interest from condyloid process to C6. The integrated transit fluence through the region of interest on the day of the cone beam computed tomography scan was calculated with the first treatment as the baseline. The correlation between fluence change and volume change was determined. A logistic regression model was also used to associate the 5% region of interest volume reduction replanning trigger point and the fluence change. The model was assessed by a chi-square test. The area under the receiver–operating characteristic curve was also determined. A total of 46 pairs of measurements were obtained. The correlation between fluence and volumetric changes was found to be −0.776 (P value <.001). The negative correlation is attributed to the increase in the photon fluence transport resulting from the volume reduction. The chi-square of the logistic regression was found to be 17.4 (P value <.001). The area under the receiver–operating characteristic curve was found to be 0.88. Results indicate the change in transit fluence, which can be measured without consuming clinical resources or requiring additional time in the treatment room, can be used as a decision support metric for adaptive therapy.