Dale Michael Lovelock

Dale Michael Lovelock

Auto-generated profile, based on publicly available information

Dale Michael Lovelock

Department of Medical Physics Memorial Sloan Kettering Cancer Center New York NY USA

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Neurosurgery: Spine
Verified
Journal Article
Open access
PDF file
OBOri Barzilai
Ori Barzilai
NDNatalie DiStefano
Natalie DiStefano
ELEric Lis
Eric Lis
YYYoshiya Yamada
Yoshiya Yamada
DLD. Michael Lovelock
D. Michael Lovelock
ILIlya Laufer
Ilya Laufer
OBJECTIVE: The aim of this study was to evaluate the safety and efficacy of kyphoplasty treatment prior to spine stereotactic radiosurgery (SRS) in patients with spine metastases.METHODS: A retrospective review of charts, radiology reports, and images was performed for all patients who received SRS (single fraction; either standalone or post-kyphoplasty) at a large tertiary cancer center between January 2012 and July 2015. Patient and tumor variables were documented, as well as treatment planning data and dosimetry. To measure the photon scatter due to polymethyl methacrylate, megavolt photon beam attenuation was determined experimentally as it passed through a kyphoplasty cement phantom. Corrected electron density values were recalculated and compared with uncorrected values.RESULTS: Of 192 treatment levels in 164 unique patients who underwent single-fraction SRS, 17 (8.8%) were treated with kyphoplasty prior to radiation delivery to the index level. The median time from kyphoplasty to SRS was 22 days. Four of 192 treatments (2%) demonstrated local tumor recurrence or progression at the time of analysis. Of the 4 local failures, 1 patient had kyphoplasty prior to SRS. This recurrence occurred 18 months after SRS in the setting of widespread systemic disease and spinal tumor progression. Dosimetric review demonstrated a lower than average treatment dose for this case compared with the rest of the cohort. There were no significant differences in dosimetry analysis between the group of patients who underwent kyphoplasty prior to SRS and the remaining patients in the cohort. A preliminary analysis of polymethyl methacrylate showed that dosimetric errors due to uncorrected electron density values were insignificant.CONCLUSIONS: In cases without epidural spinal cord compression, stabilization with cement augmentation prior to SRS is safe and does not alter the efficacy of the radiation or preclude physicians from adhering to SRS planning and contouring guidelines.

18 July 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SLSeng Boh Lim
Seng Boh Lim
PSPaola Godoy Scripes
Paola Godoy Scripes
MNMary Napolitano
Mary Napolitano
ESErgys Subashi
Ergys Subashi
NTNeelam Tyagi
Neelam Tyagi
DLDale Michael Lovelock
Dale Michael Lovelock
Objective: Adaptive radiation therapy (ART) is an integral part of MR‐guided RT (MRgRT), requiring a new RT plan for each treatment fraction and resulting in a significant increase in patient‐specific quality assurance (PSQA). This study investigates the possibility of using treatment log‐file for automated PSQA.Method: All treatment plans were delivered in 1.5T Unity MR‐Linac (Elekta). A Unity compatible version of LinacView (Standard Imaging) was commissioned to automatically monitor and analyze the log‐files. A total of 220 fields were delivered and measured by ArcCheck®‐MR (Sun Nuclear) and LinacView. Thirty incorrectly matched fields were also delivered to check for error detection sensitivity. The gamma analysis, γ, with 3%, 3 mm criteria was used in both ArcCheck®‐MR and LinacView. Additionally, the gantry angle, jaws, and multileaf collimators (MLC) positions reported in the log‐file were compared with plan positions using TG‐142 criteria.Result: The γ (3%, 3 mm) for the 190 plans were found to be between the range of 72.5%–100.0% and 95.4%–100.0% for ArcCheck®‐MR and LinacVeiw, respectively. All the delivered gantry angle and jaws were found to be within 0.2° and 2 mm. MLCs that were outside the guard leaves or under the diaphragms were found to have more than 1.0 mm discrepancy. This was attributed to the linac internal override for these MLCs and had no dosimetric impact. Excluding these discrepancies, all MLC positions were found to be within 1.0 mm. The γ (3%, 3 mm) for the 30 incorrectly matched fields were found to be 3.9%–84.8% and 0.1%–64.4% for ArcCheck®‐MR and LinacVeiw, respectively.Conclusion: Significant ranked correlation demonstrates the automated log‐file analysis can be used for PSQA and expedite the ART workflow. Ongoing PSQA will be compared with log‐file analysis to investigate the longer term reproducibility and correlation.

1 August 2008 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
SKSergey A. Kriminski
Sergey A. Kriminski
DLD. Michael Lovelock
D. Michael Lovelock
VSVenkatraman E. Seshan
Venkatraman E. Seshan
Imran AliImran Ali
Imran Ali
PMPeter Munro
Peter Munro
YYYoshiya Yamada
Yoshiya Yamada

29 March 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
LZLei Zhang
Lei Zhang
SVSarath Vijayan
Sarath Vijayan
SHSheng Huang
Sheng Huang
YSYulin Song
Yulin Song
TLTianfang Li
Tianfang Li
Guang LiGuang Li
Guang Li
Purpose: This study aimed to evaluate and compare different system calibration methods from a large cohort of systems to establish a commissioning procedure for surface‐guided frameless cranial stereotactic radiosurgery (SRS) with intrafractional motion monitoring and gating. Using optical surface imaging (OSI) to guide non‐coplanar SRS treatments, the determination of OSI couch‐angle dependency, baseline drift, and gated‐delivered‐dose equivalency are essential.Methods: Eleven trained physicists evaluated 17 OSI systems at nine clinical centers within our institution. Three calibration methods were examined, including 1‐level (2D), 2‐level plate (3D) calibration for both surface image reconstruction and isocenter determination, and cube phantom calibration to assess OSI‐megavoltage (MV) isocenter concordance. After each calibration, a couch‐angle dependency error was measured as the maximum registration error within the couch rotation range. A head phantom was immobilized on the treatment couch and the isocenter was set in the middle of the brain, marked with the room lasers. An on‐site reference image was acquired at couch zero, the facial region of interest (ROI) was defined, and static verification images were captured every 10° for 0°–90° and 360°–270°. The baseline drift was assessed with real‐time monitoring of the motionless phantom over 20 min. The gated‐delivered‐dose equivalency was assessed using the electron portal imaging device and gamma test (1%/1mm) in reference to non‐gated delivery.Results: The maximum couch‐angle dependency error occurs in longitudinal and lateral directions and is reduced significantly (P < 0.05) from 1‐level (1.3 ± 0.4 mm) to 2‐level (0.8 ± 0.3 mm) calibration. The MV cube calibration does not further reduce the couch‐angle dependency error (0.8 ± 0.2 mm) on average. The baseline drift error plateaus at 0.3 ± 0.1 mm after 10 min. The gated‐delivered‐dose equivalency has a >98% gamma‐test passing rate.Conclusion: A commissioning method is recommended using the 3D plate calibration, which is verified by radiation isocenter and validated with couch‐angle dependency, baseline drift, and gated‐delivered‐dose equivalency tests. This method characterizes OSI uncertainties, ensuring motion‐monitoring accuracy for SRS treatments.

26 February 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SLSeng Boh Lim
Seng Boh Lim
BZBenjamin J. Zwan
Benjamin J. Zwan
DLDanny Lee
Danny Lee
PGPeter Greer
Peter Greer
DLDale Michael Lovelock
Dale Michael Lovelock
The use of trajectory log files for routine patient quality assurance is gaining acceptance. Such use requires the validation of the trajectory log itself. However, the accurate localization of a multileaf collimator (MLC) leaf while it is in motion remains a challenging task. We propose an efficient phantom‐less technique using the EPID to verify the dynamic MLC positions with high accuracy. Measurements were made on four Varian TrueBeams equipped with M120 MLCs. Two machines were equipped with the S1000 EPID; two were equipped with the S1200 EPID. All EPIDs were geometrically corrected prior to measurements. Dosimetry mode EPID measurements were captured by a frame grabber card directly linked to the linac. All leaf position measurements were corrected both temporally and geometrically. The readout latency of each panel, as a function of pixel row, was determined using a 40 × 1.0 cm2 sliding window (SW) field moving at 2.5 cm/s orthogonal to the row readout direction. The latency of each panel type was determined by averaging the results of two panels of the same type. Geometric correction was achieved by computing leaf positions with respect to the projected isocenter position as a function of gantry angle. This was determined by averaging the central axis position of fields at two collimator positions of 90° and 270°. The radiological to physical leaf end position was determined by comparison of the measured gap with that determined using a feeler gauge. The radiological to physical leaf position difference was found to be 0.1 mm. With geometric and latency correction, the proposed method was found to be improve the ability to detect dynamic MLC positions from 1.0 to 0.2 mm for all leaves. Latency and panel residual geometric error correction improve EPID‐based MLC position measurement. These improvements provide for the first time a trajectory log QA procedure.

12 November 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
HKHsiang‐Chi Kuo
Hsiang‐Chi Kuo
MLMichael M. Lovelock
Michael M. Lovelock
Guang LiGuang Li
Guang Li
ÅBÅse Ballangrud
Åse Ballangrud
BWBrian Wolthuis
Brian Wolthuis
SBSean L. Berry
Sean L. Berry
Purpose: To evaluate two three‐dimensional (3D)/3D registration platforms, one two‐dimensional (2D)/3D registration method, and one 3D surface registration method (3DS). These three technologies are available to perform six‐dimensional (6D) registrations for image‐guided radiotherapy treatment.Methods: Fiducial markers were asymmetrically placed on the surfaces of an anthropomorphic head phantom (n = 13) and a body phantom (n = 8), respectively. The point match (PM) solution to the six‐dimensional (6D) transformation between the two image sets [planning computed tomography (CT) and cone beam CT (CBCT)] was determined through least‐square fitting of the fiducial positions using singular value decomposition (SVD). The transformation result from SVD was verified and was used as the gold standard to evaluate the 6D accuracy of 3D/3D registration in Varian’s platform (3D3DV), 3D/3D and 2D/3D registration in the BrainLab ExacTrac system (3D3DE and 2D3D), as well as 3DS in the AlignRT system. Image registration accuracy from each method was quantitatively evaluated by root mean square of target registration error (rmsTRE) on fiducial markers and by isocenter registration error (IRE). The Wilcoxon signed‐rank test was utilized to compare the difference of each registration method with PM. AP < 0.05 was considered significant.Results: rmsTREwas in the range of 0.4 mm/0.7 mm (cranial/body), 0.5 mm/1 mm, 1.0 mm/1.5 mm, and 1.0 mm/1.2 mm for PM, 3D3D, 2D3D, and 3DS, respectively. Comparing to PM, the mean errors ofIREwere 0.3 mm/1 mm for 3D3D, 0.5 mm/1.4 mm for 2D3D, and 1.6 mm/1.35 mm for 3DS for the cranial and body phantoms respectively. Both of 3D3D and 2D3D methods differed significantly in the roll direction as compared to the PM method for the cranial phantom. The 3DS method was significantly different from the PM method in all three translation dimensions for both the cranial (P = 0.003–P = 0.03) and body (P < 0.001–P = 0.008) phantoms.Conclusion: 3D3D using CBCT had the best image registration accuracy among all the tested methods. 2D3D method was slightly inferior to the 3D3D method but was still acceptable as a treatment position verification device. 3DS is comparable to 2D3D technique and could be a substitute for X‐ray or CBCT for pretreatment verification for treatment of anatomical sites that are rigid.