Representative Publications

View All Publications
25 August 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SRS. A. Ranamukhaarachchi
S. A. Ranamukhaarachchi
SLS. Lehnert
S. Lehnert
SRS. L. Ranamukhaarachchi
S. L. Ranamukhaarachchi
LSL. Sprenger
L. Sprenger
TST. Schneider
T. Schneider
BBBoris Boris
Boris Boris
Collecting human skin samples for medical research, including developing microneedle-based medical devices, is challenging and time-consuming. Researchers rely on human skin substitutes and skin preservation techniques, such as freezing, to overcome the lack of skin availability. Porcine skin is considered the best substitute to human skin, but their mechanical resemblance has not been fully validated. We provide a direct mechanical comparison between human and porcine skin samples using a conventional mechano-analytical technique (microindentation) and a medical application (microneedle insertion), at 35% and 100% relative humidity. Human and porcine skin samples were tested immediately after surgical excision from subjects, and after one freeze-thaw cycle at −80 °C to assess the impact of freezing on their mechanical properties. The mechanical properties of fresh human and porcine skin (especially of the stratum corneum) were found to be different for bulk measurements using microindentation; and both types of skin were mechanically affected by freezing. Localized in-plane mechanical properties of skin during microneedle insertion appeared to be more comparable between human and porcine skin samples than their bulk out-of-plane mechanical properties. The results from this study serve as a reference for future mechanical tests conducted with frozen human skin and/or porcine skin as a human skin substitute.

5 March 2021 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
MJMaziyar Jalaal
Maziyar Jalaal
BBBoris Boris
Boris Boris
NBNeil J. Balmforth
Neil J. Balmforth
The spreading under surface tension and gravity of a droplet of yield-stress fluid over a thin film of the same material is studied. The droplet converges to a final equilibrium shape once the driving stresses inside the droplet fall below the yield stress. Scaling laws are presented for the final radius and complemented with an asymptotic analysis for shallow droplets. Moreover, numerical simulations using the volume-of-fluid method and a regularized constitutive law, and experiments with an aqueous solution of Carbopol, are presented.

4 April 2009 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
UHUrs Hafeli
Urs Hafeli
AMAmir Mokhtari
Amir Mokhtari
DLDorian Liepmann
Dorian Liepmann
BBBoris Boris
Boris Boris

15 December 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LKLance Kersey
Lance Kersey
VEVincent Ebacher
Vincent Ebacher
VBVahid Bazargan
Vahid Bazargan
RWRizhi Wang
Rizhi Wang
BBBoris Boris
Boris Boris
The effect of the adhesion promoter GE SS4120 on the adhesion strength of PDMS to different substrates was tested. The adhesion to silicon, glass and aluminium was significantly increased, while adhesion of PDMS to Teflon® remained poor, and the adhesion strength of PDMS to PDMS decreased.

1 February 2021 in Journal of Drug Delivery Science and Technology
Verified
Journal Article
Open access
LWLibo Wu
Libo Wu
PSPranav Shrestha
Pranav Shrestha
MIMartina Iapichino
Martina Iapichino
YCYicheng Cai
Yicheng Cai
BKBeomjoon Kim
Beomjoon Kim
BBBoris Boris
Boris Boris

26 May 2015 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
IMIman Mansoor
Iman Mansoor
JLJacqueline Lai
Jacqueline Lai
SRSahan Ranamukhaarachchi
Sahan Ranamukhaarachchi
VSVeronika Schmitt
Veronika Schmitt
DLDana Lambert
Dana Lambert
BBBoris Boris
Boris Boris