Teh-Hua Tsai

Dr. Teh-Hua Tsai

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2025 in Polymers
Verified
Journal Article
Open access
PDF file
KHKuang-Yuan Hsiao
Kuang-Yuan Hsiao
RCRen-Jei Chung
Ren-Jei Chung
Chang Pi PaiChang Pi Pai
Chang Pi Pai
TTTeh-Hua Tsai
Teh-Hua Tsai
This investigation of hydroxyl and polysiloxane absorption peaks in elastic polymer composites reveals significant spectral shifts within the fingerprint region of FTIR spectra. Using poly(vinyl butyral) (PVB) as the base polymer and poly(vinyl acetate) (PVAc) and poly(vinyl alcohol) (PVA) as reference materials, solvent effects on polymer–solvent interactions were systematically analyzed. Among the tested alcohol solvents, PEG 400 induced the most pronounced spectral changes, with the C=O stretching band shifting from 1740 to 1732 cm−1 and the O–H band significantly broadening and downshifting to around 3300 cm−1, reflecting strong hydrogen-bonding interactions. Wavelet-based noise reduction effectively enhanced the signal-to-noise ratio, reducing the baseline standard deviation by over 90%. This study introduces a novel noise-enhanced FTIR recognition model that integrates baseline noise metrics to improve detection sensitivity. The model successfully uncovers subtle structural variations in polymer–solvent systems that are typically masked by conventional FTIR techniques, advancing materials analysis and providing a robust framework for future FTIR-based diagnostics and material characterization.

27 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
LWLi-Chun Wu
Li-Chun Wu
TTTeh-Hua Tsai
Teh-Hua Tsai
MLMan-Hai Liu
Man-Hai Liu
JKJui-Ling Kuo
Jui-Ling Kuo
YCYung-Chu Chang
Yung-Chu Chang
Ying-Chien ChungYing-Chien Chung
Ying-Chien Chung
The extensive use of Cr(VI) in many industries and the disposal of Cr(VI)-containing wastes have resulted in Cr(VI)-induced environmental contamination. Cr(VI) compounds are associated with increased cancer risks; hence, the detection of toxic Cr(VI) compounds is crucial. Various methods have been developed for Cr(VI) measurement, but they are often conducted offsite and cannot provide real-time toxicity monitoring. A microbial fuel cell (MFC) is an eco-friendly and self-sustaining device that has great potential as a biosensor for in situ Cr(VI) measurement, especially for wastewater generated from different electroplating units. In this study, Exiguobacterium aestuarii YC211, a facultatively anaerobic, Cr(VI)-reducing, salt-tolerant, and exoelectrogenic bacterium, was isolated and inoculated into an MFC to evaluate its feasibility as a Cr(VI) biosensor. The Cr(VI) removal efficiency of E. aestuarii YC211 was not affected by the surrounding environment (pH 5–9, 20–35 °C, coexisting ions, and salinity of 0–15 g/L). The maximum power density of the MFC biosensor was 98.3 ± 1.5 mW/m2 at 1500 Ω. A good linear relationship (r2 = 0.997) was observed between the Cr(VI) concentration (2.5–60 mg/L) and the voltage output. The developed MFC biosensor is a simple device that can accurately measure Cr(VI) concentrations in the actual electroplating wastewater that is generated from different electroplating units within 30 min with low deviations (−6.1% to 2.2%). After treating the actual electroplating wastewater with the MFC, the predominant family in the biofilm was found to be Bacillaceae (95.3%) and was further identified as the originally inoculated E. aestuarii YC211 by next generation sequencing (NGS). Thus, the MFC biosensor can measure Cr(VI) concentrations in situ in the effluents from different electroplating units, and it can potentially help in preventing the violation of effluent regulations.

1 January 2014 in Desalination and Water Treatment
Verified
Journal Article
Open access
CPChen-Yu Peng
Chen-Yu Peng
TTTeh-Hua Tsai
Teh-Hua Tsai
In this study, the effect of different operating conditions including on the extraction of palladium (II) from HCl solution by using tri-n-octylmethylammonium chloride (Aliquat 336)/kerosene was evaluated at 25°C. Different stripping reagents such as AlCl3, KCl, NaCl, NH4Cl, HCl, and thiourea were evaluated. The results indicate that the mixture of chloride and thiourea would lead to the highest stripping conversion for palladium (II) (i.e. >99%).The extraction distribution ratios were found to increase with the increase in the extractant concentration and decrease with the concentration of chloride ion. In addition, the compositions of palladium complexes in organic phase and equilibrium constant of recovered extraction reaction were estimated. Furthermore, the recovery efficiency of palladium(II) in acidic chloride solution was performed and compared.

24 December 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
JKJong-tar Kuo
Jong-tar Kuo
LCLi-Li Chang
Li-Li Chang
CYChia-Yuan Yen
Chia-Yuan Yen
TTTeh-Hua Tsai
Teh-Hua Tsai
YCYu-Chi Chang
Yu-Chi Chang
Ying-Chien ChungYing-Chien Chung
Ying-Chien Chung
Coliform bacteria are indicators of water quality; however, most detection methods for coliform bacteria are time-consuming and nonspecific. Here, we developed a fluorescence in situ hybridization (FISH) approach to detect four types of coliform bacteria, including Escherichia coli, Klebsiella pneumoniae, Enterobacter aerogenes, and Citrobacter freundii, simultaneously in water samples using specific probes for 16S rRNA. This FISH method was applied to detect coliform bacteria in simulated water and domestic wastewater samples and compared with traditional detection methods (e.g., plate counting, multiple-tube fermentation (MTF) technique, and membrane filter (MF) technique). Optimal FISH conditions for detecting the four types of coliforms were found to be fixation in 3% paraformaldehyde at 4 °C for 2 h and hybridization at 50 °C for 1.5 h. By comparing FISH with plate counting, MTF, MF, and a commercial detection kit, we found that FISH had the shortest detection time and highest accuracy for the identification of coliform bacteria in simulated water and domestic wastewater samples. Moreover, the developed method could simultaneously detect individual species and concentrations of coliform bacteria. Overall, our findings indicated that FISH could be used as a rapid, accurate biosensor system for simultaneously detecting four types of coliform bacteria to ensure water safety.

27 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
GWGuey-Horng Wang
Guey-Horng Wang
CCChiu-Yu Cheng
Chiu-Yu Cheng
TTTeh-Hua Tsai
Teh-Hua Tsai
PCPin-Kuan Chiang
Pin-Kuan Chiang
Ying-Chien ChungYing-Chien Chung
Ying-Chien Chung
In this study, we constructed a recombinant Escherichia coli strain with different promoters inserted between the chromate-sensing regulator chrB and the reporter gene luxAB to sense low hexavalent chromium (Cr(VI)) concentrations (<0.05 mg/L); subsequently, its biosensor characteristics (sensitivity, selectivity, and specificity) for measuring Cr(VI) in various water bodies were evaluated. The luminescence intensity of each biosensor depended on pH, temperature, detection time, coexisting carbon source, coexisting ion, Cr(VI) oxyanion form, Cr(VI) concentration, cell type, and type of medium. Recombinant lux-expressing E. coli with the T7 promoter (T7-lux-E. coli, limit of detection (LOD) = 0.0005 mg/L) had the highest luminescence intensity or was the most sensitive for Cr(VI) detection, followed by E. coli with the T3 promoter (T3-lux-E. coli, LOD = 0.001 mg/L) and that with the SP6 promoter (SP6-lux-E. coli, LOD = 0.005 mg/L). All biosensors could be used to determine whether the Cr(VI) standard was met in terms of water quality, even when using thawing frozen cells as biosensors after 90-day cryogenic storage. The SP6-lux-E. coli biosensor had the shortest detection time (0.5 h) and the highest adaptability to environmental interference. The T7-lux-E. coli biosensor—with the optimal LOD, a wide measurement range (0.0005–0.5 mg/L), and low deviation (−5.0–7.9%) in detecting Cr(VI) from industrial effluents, domestic effluents, and surface water—is an efficient Cr(VI) biosensor. This unprecedented study is to evaluate recombinant lux E. coli with dissimilar promoters for their possible practice in Cr(VI) measurement in water bodies, and the biosensor performance is clearly superior to that of past systems in terms of detection time, LOD, and detection deviation for real water samples.

22 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LWLi-Chun Wu
Li-Chun Wu
GWGuey-Horng Wang
Guey-Horng Wang
TTTeh-Hua Tsai
Teh-Hua Tsai
SLShih-Yu Lo
Shih-Yu Lo
CCChiu-Yu Cheng
Chiu-Yu Cheng
Ying-Chien ChungYing-Chien Chung
Ying-Chien Chung
Chromium (VI) [Cr(VI)] compounds display high toxic, mutagenic, and carcinogenic potential. Biological analysis techniques (e.g., such as enzyme-based or cell-based sensors) have been developed to measure Cr(VI); however, these biological elements are sensitive to the environment, limited to measuring trace Cr(VI), and require deployment offsite. In this study, a three-stage single-chambered microbial fuel cell (SCMFC) biosensor inoculated with Exiguobacterium aestuarii YC211 was developed for in situ, real-time, and continuous Cr(VI) measurement. A negative linear relationship was observed between the Cr(VI) concentration (5–30 mg/L) and the voltage output using an SCMFC at 2-min liquid retention time. The theoretical Cr(VI) measurement range of the system could be extended to 5–90 mg/L by connecting three separate SCMFCs in series. The three-stage SCMFC biosensor could accurately measure Cr(VI) concentrations in actual tannery wastewater with low deviations (92.5%), according to the next-generation sequencing analysis. The stable bacterial community present in the SCMFC favored the reliable performance of the SCMFC biosensor. Thus, the three-stage SCMFC biosensor has potential as an early warning device with wide dynamic range for in situ, real-time, and continuous Cr(VI) measurement of tannery wastewater.