The thermal and electrical efficiency of a custom-designed PV/T panel cooled by forced air circulation was investigated by experimental and computational fluid dynamics (CFD) analysis. Experiments were carried out with four different array configurations, under constant irradiation of 1100 W/m2 and 3 different air velocities (3.3 m/s, 3.9 m/s, and 4.5 m/s). The heat transfer surface area and forced air circulation are known to positively affect the total heat transfer, and therefore, it is foreseeable that an increased number of fins and higher air velocities will help maintain the electrical efficiency of the panel at higher levels. The main objective of this study is to determine the critical threshold for the abovementioned parameters as well as to show how important parameters, such as fin arrangement and consequent turbulent air flows, are for satisfying the heat removal needs. Highest efficiency was achieved with a 108 pc type 1 arrangement at 12.02% as expected. Nevertheless, while the 108 pc type 2 arrangement could maintain the electrical efficiency at 11.81%, a close level of 11.55% could be obtained with a 54 pc type 2 arrangement. Experimental results are compared with ANSYS Fluent program, and the effect of the number and arrangement of the fins on the efficiency of the panel has been shown.
This experimental study deals with the heat transfer and friction effects of sinusoidal part turbulators for single-phase flows occurring in a circular shaped pipe. Turbulators with three different radius values are placed in the pipe to make the flow turbulent. In this way, changes in Nusselt number and friction coefficient are examined. As a result of the experiments made with Reynolds numbers in the range of 6614-20710, the increase rates of the Nusselt numbers of turbulators with 20 mm, 110 mm, and 220 mm radius compared to the empty pipe were obtained as 153.49%, 85.36%, and 52.09%, respectively. As a result of the decrease in the radius, there was an increase in the Nusselt number and the friction factor. Parallel to the Nusselt number, the highest friction factor was obtained in the smallest radius turbulator. It was found that the thermal enhancement factors of 110 mm and 220 mm radius turbulators increased by 179.54% and 132.95%, respectively, compared to the 20 mm radius turbulator. Similarly, it was determined that the thermal enhancement factor of the 110 mm radius turbulator increased by 20% compared to the 220 mm radius turbulator.
Being the most widespread renewable energy generation system, photovoltaic (PV) systems face major problems, overheating and low overall conversion efficiency. The electrical efficiency of PV systems is adversely affected by significant increases in cell temperature upon exposure to solar irradiation. There have been several ways to remove excess heat and cool down the PV to maintain efficiency at fair levels. A hybrid photovoltaic/thermal system cooled by forced air circulation blown by a PV-powered fan was set up, and a rectangular control volume with cylindrical ends was built at the back of the PV panel where aluminum fins were placed in different arrangements and numbers. During the experiments, temperature and electrical output parameters were measured for three different air velocities (3.3, 3.9, and 4.5 m/s) and two different fin numbers and arrangements (54 pcs shifted and 108 pcs inline) under a constant radiation value of 1350 W/m2. While the electrical efficiency of the panel was reduced by almost 50% and decreased from 12% to 6.8% without active cooling, at 4.5-m/s air velocity and with 108 fins in inline arrangement, the electrical efficiency could be maintained at 11.5%. To compare and verify the experimental results, a heat transfer simulation model was developed with the ANSYS Fluent, and a good fit between the simulation and the test results was obtained.
1 January 2013 in Journal of Enhanced Heat Transfer
Turbulence promoting inner elements such as rings, wings or winglets, twisted tapes, etc., is widely used in single- and two-phase flows. In this experimental work, the two-phase flow instabilities of forced convection boiling in a horizontal tube with ring- and twisted-tape-type inner elements inside are investigated. In order to analyze the two-phase flow of water, the experiments were conducted under a constant system pressure of 7.5 bar, and a constant heat input of 24 kW was applied to the outer surface of the circular test pipe with constant exit restriction. Three different inlet temperatures (Ti = 15, 25, and 35°C) were used to see the effect of inlet sub-cooling, and the mass flow rate was decreased from 110 to 20 g/s to obtain the characteristic curve. Two different pitch ratios for both the ring and twisted tape were evaluated in terms of stability. The results were evaluated in terms of appropriate variables for both the tube with insertions and the smooth tube. The analysis shows that the pressure drop increases with decreasing mass flow rate for all cases. The presence of the inner elements in the test pipe causes the boundaries of the oscillations to narrow in comparison with smooth tube. On the other hand, with the increase in the effective diameter of the test pipe the boundaries of the oscillations broaden. For each type of insertion, the increase of the pitch ratio makes the system less stable.
18 October 2017 in Periodicals of Engineering and Natural Sciences (PEN)
The aim of this study is to experimentally investigate the effect of the coiled wire insertions on dynamic instabilities and to compare the results with the smooth tube for forced convection boiling. The experiments were conducted in a circular tube, and water was used as the working fluid. Two different pitch ratios (H/D = 2.77 and 5.55) of coiled wire with circular cross‐sections were utilised. The constant heat flux boundary condition was applied to the outer side of the test tube, and the constant exit restriction was used at the tube outlet. The mass flow rate changed from 110 to 20 g/s in order to obtain a detailed idea about the density wave and pressure drop oscillations, and the range of the inlet temperature was 15–35°C. The changes in pressure drop, inlet temperature, amplitude, and the period with mass flow rate are presented. For each configuration, it is seen that density wave and pressure drop oscillations occur at all inlet temperatures. Analyses show that the decrease in the mass flow rate and inlet temperature causes the amplitude and the period of the density wave and the pressure drop oscillations to decrease separately.