Ciobanu Razvan

Mr. Ciobanu Razvan


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2024 in Inventions
Verified
Journal Article
Open access
PDF file
FFFlorean Gabriel Florin
Florean Gabriel Florin
AMAndreea Mangra
Andreea Mangra
MEMarius Enache
Marius Enache
DMDeaconu Marius
Deaconu Marius
CRCiobanu Razvan
Ciobanu Razvan
RCRazvan Carlanescu
Razvan Carlanescu
A new afterburner installation is proposed, fueled with pure hydrogen (100%H2) or hydrogen–methane mixtures (60% H2 + 40% CH4, 80% H2 + 20% CH4) for use in cogeneration applications. Two prototypes (P1 and P2) with the same expansion angle (45 degrees) were developed and tested. P1 was manufactured by the classic method and P2 by additive manufacturing. Both prototypes were manufactured from Inconel 625. During the tests, analysis of flue gas (CO2, CO, and NO concentration), PIV measurements, and noise measurements were conducted. The flue gas analysis emphasizes that the behavior of the two tested prototypes was very similar. For all three fuels used, the CO2 concentration levels were slightly lower in the case of the additive-manufactured prototype P2. The CO concentration levels were significantly higher in the case of the additive-manufactured prototype P2 when 60% H2/40% CH4 and 80% H2/20% CH4 mixtures were used as fuel. When pure H2 was used as fuel, the measured data suggest that no additional CO was produced during the combustion process, and the level of CO was similar to that from the Garrett micro gas turbine in all five measuring points. The NO emissions gradually decreased as the percentage of H2 in the fuel mixture increased. The NO concentration was significantly lower in the case of the additive-manufactured prototype (P2) in comparison with the classic manufactured prototype (P1). Examining the data obtained from the PIV measurements of the flow within the mixing region shows that the highest axial velocity component value on the centerline was measured for the P1 prototype. The acoustic measurements showed that a higher H2 concentration led to a reduction in noise of approximately 1.5 dB for both afterburner prototypes. The outcomes reveal that the examined V-gutter flame holder prototype flow was smooth, without any perpendicular oscillations, without chaotic motions or turbulent oscillations to the flow direction, across all tested conditions, keeping constant thermal power.

5 October 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
CRCiobanu Razvan
Ciobanu Razvan
ASAdrian Stoicescu
Adrian Stoicescu
CNCristian Nechifor
Cristian Nechifor
ATAlexandra Taranu
Alexandra Taranu
The proposed concept presents an innovative test cell control system, compatible with an existing APU (Auxiliary Power Unit) test cell. The system is essentially a Non-Propulsive Energy (NPE) Power Management Unit that needs to efficiently distribute power among an aircraft’s pneumatic and electrical loads, based on key parameters read from: loads (electrical, pneumatical), a real APU and real-time models of main engines representative to the aircraft. For this, the concept suggests a hardware & software solution, based on the approach of Artificial Neural Network (ANN). The ANN processes all inputs according to a mathematical law trained from existing data sets, such that minimal power loss is considered, given all safety levels are achieved. Development of the neural network is made such that the fastest response time and best performance consist as general goals, and the resulting control system is tested via Hardware-in-the-Loop simulation. Thus, the neural network is also designed to be safe and stable given maximum performance. The hardware solution describes all the equipment included to fulfil the objectives of the concept.