A new afterburner installation is proposed, fueled with pure hydrogen (100%H2) or hydrogen–methane mixtures (60% H2 + 40% CH4, 80% H2 + 20% CH4) for use in cogeneration applications. Two prototypes (P1 and P2) with the same expansion angle (45 degrees) were developed and tested. P1 was manufactured by the classic method and P2 by additive manufacturing. Both prototypes were manufactured from Inconel 625. During the tests, analysis of flue gas (CO2, CO, and NO concentration), PIV measurements, and noise measurements were conducted. The flue gas analysis emphasizes that the behavior of the two tested prototypes was very similar. For all three fuels used, the CO2 concentration levels were slightly lower in the case of the additive-manufactured prototype P2. The CO concentration levels were significantly higher in the case of the additive-manufactured prototype P2 when 60% H2/40% CH4 and 80% H2/20% CH4 mixtures were used as fuel. When pure H2 was used as fuel, the measured data suggest that no additional CO was produced during the combustion process, and the level of CO was similar to that from the Garrett micro gas turbine in all five measuring points. The NO emissions gradually decreased as the percentage of H2 in the fuel mixture increased. The NO concentration was significantly lower in the case of the additive-manufactured prototype (P2) in comparison with the classic manufactured prototype (P1). Examining the data obtained from the PIV measurements of the flow within the mixing region shows that the highest axial velocity component value on the centerline was measured for the P1 prototype. The acoustic measurements showed that a higher H2 concentration led to a reduction in noise of approximately 1.5 dB for both afterburner prototypes. The outcomes reveal that the examined V-gutter flame holder prototype flow was smooth, without any perpendicular oscillations, without chaotic motions or turbulent oscillations to the flow direction, across all tested conditions, keeping constant thermal power.
A considerable number of Combined Heat and Power (CHP) systems continue to depend on fossil fuels like oil and natural gas, contributing to significant environmental pollution and the release of greenhouse gases. Two V-gutter flame holder prototypes (P1 and P2) with the same expansion angle, fueled with pure hydrogen (100% H2) or hydrogen–methane mixtures (60% H2 + 40% CH4, 80% H2 + 20% CH4), intended for use in cogeneration applications, have been designed, manufactured, and tested. Throughout the tests, the concentrations of CO2, CO, and NO in the flue gas were monitored, and particle image velocimetry (PIV) measurements were performed. The CO, CO2, respectively, and NO emissions gradually decreased as the percentage of H2 in the fuel mixture increased. The NO emissions were significantly lower in the case of prototype P2 in comparison with prototype P1 in all measurement points for all used fuel mixtures. The shortest recirculation zone was observed for P1, where the axial velocity reaches a negative peak of approximately 12 m/s at roughly 50 mm downstream of the edge of the flame holder, and the recirculation region spans about 90 mm. In comparison, the P2 prototype has a length of the recirculation region span of about 100 mm with a negative peak of approximately 14 m/s. The data reveal high gradients in flow velocity near the flow separation point, which gradually smooth out with increasing downstream distance. Despite their similar design, P2 consistently performs better across all measured velocity components. This improvement can be attributed to the larger fuel injection holes, which enhance fuel–air mixing and combustion stability. Additionally, the presence of side walls directing the flow around the flame stabilizer further aids in maintaining a stable combustion process.
The stability of hydrogen-fueled flames in afterburner systems is crucial for advancing clean energy technologies but is challenged by intense turbulence and flow variability. This study uniquely integrates advanced particle image velocimetry (PIV) techniques to investigate the flow dynamics around a V-gutter flame holder fueled with 100% hydrogen. Detailed velocity measurements were conducted to analyze the standard deviation of Vy, average Vy, average V, and uncertainty of Vy, as well as the mean swirling strength and mean vorticity profiles across multiple horizontal and vertical lines. The results reveal significant flow variability and turbulence intensity near the flame holder, with standard deviation peaks of up to 12 m/s, indicating zones of high turbulence and potential flame instability. The mean swirling strength, peaking at 850,000 [1/s2], and vorticity values up to 5000 [1/s] highlight intense rotational motion, enhancing fuel–air mixing and flame stabilization. The average Vy remained stable near the centerline, ensuring balanced flow conditions, while lateral deviations of up to −10 m/s reflect vortical structures induced by the flame holder geometry. Low uncertainty values, typically below 1 m/s, validate the precision of the PIV measurements, ensuring a reliable representation of the flow field. By providing a detailed analysis of turbulence structures and their impact on hydrogen combustion, this study offers novel insights into the interplay between flow dynamics and flame stability. These findings not only advance the understanding of hydrogen-fueled afterburner systems but also demonstrate the critical role of rotational flow structures in achieving stable and efficient combustion. By addressing key challenges in hydrogen combustion, this study provides a foundation for designing more robust and environmentally sustainable combustion systems, contributing to the transition toward clean energy technologies.
Sustainable Aviation Fuel (SAF) offers a near-term route to reducing aviation’s dependence on fossil kerosene, but engine-level data for blends above the current 50% blending limit remain scarce, particularly for small turbine-based hybrid-electric power systems. In this study, HEFA-SAF/kerosene blends containing 15%, 30%, 50%, 75%, and 100% SAF by volume, together with conventional kerosene as reference fuel, were tested in a KingTech micro-turboprop engine coupled to an electric generator supplying a 48 V DC bus for UAV applications. Four operating regimes, from idle to approximately 2 kW electrical output, were maintained for three minutes each while throttle, electrical output, and exhaust gas concentrations of NO, CO, CO2, and O2 were recorded. The throttle required for a given electrical power was largely unchanged across the blending range, and the engine operated without observable anomalies on neat SAF. CO and CO2 concentrations showed only small fuel-dependent differences, whereas the measured NO concentration showed a decreasing trend as the SAF percentage increased under all tested regimes. Since fuel flow rate, exhaust gas temperature and repeated runs were not available in the present campaign, these results should be interpreted as preliminary concentration-based trends. The study provides a preliminary engine-level dataset for high-HEFA SAF blends in a micro-turboprop hybrid-electric power generation system and identifies the measurements required for future fuel-normalized validation.
1 January 2021 in IOP Conference Series: Materials Science and Engineering
In this article will be described the improved test stand for rotating labyrinth seals that will be developed at COMOTI. The present test rig is able to test only a seal configuration in a simplified environment, (air temperature max.150° C, labyrinth diameter max. 300 mm, airflow rate max. 0.35 kg/s, pressure max. 9 bars). The newly improved research infrastructure will be able to increase these limits up to: 800°C temperature, 600 mm labyrinth diameter, 10 kg/s airflow rate and 50 bars pressure. The upgrade performed on to this research facility will comprise of a test rig for experimental measurements; a air supply station with two centrifugal compressors; an air cooling tower; a air tank to store high pressure air and an air heater station capable to supply air with 800°C.