Muhammad Waqas

Mr. Muhammad Waqas


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
MWMuhammad Waqas
Muhammad Waqas
APArvydas Palevicius
Arvydas Palevicius
VJVytautas Jurėnas
Vytautas Jurėnas
KPKestutis Pilkauskas
Kestutis Pilkauskas
Giedrius JanusasGiedrius Janusas
Giedrius Janusas
In recent years, microfluidics has emerged as an interdisciplinary field, receiving significant attention across various biomedical applications. Achieving a noticeable mixing of biofluids and biochemicals at laminar flow conditions is essential in numerous microfluidics systems. In this research work, a new kind of micromixer design integrated with an Archimedes screw is designed and investigated using numerical simulation and experimental approaches. First, the geometrical parameters such as screw length (l), screw pitch (p) and gap (s) are optimized using the Design of Expert (DoE) approach and the Central Composite Design (CCD) method. The experimental designs generated by DoE are then numerically simulated aiming to determine Mixing Index (MI) and Performance Index (PI). For this purpose, COMSOL Multiphysics with two physics modules—laminar and transport diluted species—is used. The results revealed a significant influence of screw length, screw pitch and gap on mixing performance. The optimal design achieved is then scaled up and fabricated using a 3D additive manufacturing technique. In addition, the optimal micromixer design is numerically and experimentally investigated at diverse Reynolds numbers, ranging from 2 to 16. The findings revealed the optimal geometrical parameters that produce the best result compared to other designs are a screw length of 0.5 mm, screw pitch of 0.23409 mm and a 0.004 mm gap. The obtained values of the mixing index and the performance index are 98.47% and 20.15 Pa−1, respectively. In addition, a higher mixing performance is achieved at the lower Reynolds number of 2, while a lower mixing performance is observed at the higher Reynolds number of 16. This study can be very beneficial for understanding the impact of geometrical parameters and their interaction with mixing performance.

19 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MWMuhammad Waqas
Muhammad Waqas
Giedrius JanusasGiedrius Janusas
Giedrius Janusas
VNVytenis Naginevičius
Vytenis Naginevičius
APArvydas Palevicius
Arvydas Palevicius
Today, microfluidics has become a revolutionary interdisciplinary topic with considerable attention in a wide range of biotechnology applications. In this research work, a numerical investigation of a microfluidic micromixer is carried out using a hybrid actuation approach with different micropillar shapes and gaps. For this purpose, COMSOL Multiphysics v.5.2. is used with three different physics, such as thermoviscous acoustic physics to solve acoustic governing equations, laminar physics to solve fluid flow governing equations, and diluted transport species to solve mixing governing equations. The simulations were carried out at different Reynolds numbers such as 2, 4, 6, 8, 10, and 12 with an oscillation frequency of 15 kHz. The results were in the form of acoustic characteristics such as acoustic pressure, acoustic velocity, acoustic stream, mixing index, and fluid flow behaviour at various Reynolds numbers. The results revealed that the inclusion of micropillars improved the mixing performance and strength of the acoustic field, resulting in an improvement of the mixing performance compared to the case without micropillars. In addition, the mixing performance is also investigated at different Reynolds numbers, and a higher mixing index is investigated at lower Reynolds numbers. Moreover, it was also investigated that blade-shaped micropillars with 0.150 mm gaps deliver the best results compared to the other cases, and the maximum and minimum values of the mixing index are 0.97 and 0.72, respectively, at Reynolds number 2. The main reason behind this larger mixing index at low Reynolds numbers is due to the inclusion of micropillars that enhance the diffusion rate and contact area, leading to the homogenisation of the heterogeneous fluids in the microchamber. The obtained results can be extremely helpful for the design and modifications of a hybrid microfluidics micromixer.

27 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MWMuhammad Waqas
Muhammad Waqas
Giedrius JanusasGiedrius Janusas
Giedrius Janusas
VNVytenis Naginevičius
Vytenis Naginevičius
APArvydas Palevicius
Arvydas Palevicius
Nowadays, microfluidics has become an anarchist interdisciplinary topic with considerable attention in a wide range of biotechnology applications. In this research work, numerical investigation of microfluidic micro-mixer is carried out using hybrid actuation approach with different micropillar shapes and gaps. For this purpose, COMSOL Multiphysics is used with three different physics such as thermoviscous acoustic to solve acoustic governing equations, laminar physics is used to solve fluid flow governing equations and diluted transport species is used to solve mixing governing equations. The simulations were carried out with flow velocity of 200 µm/s at both inlets with an oscillation frequency of 15kHz. The outcomes were in the form of acoustic characteristics such as acoustic pressure, acoustic velocity, acoustic streaming and mixing index. The results revealed that the inclusion of micropillars enhanced the mixing performance and strength of acoustic field resulting in improvement of mixing performance compared to the case without micropillars. In addition, it was also investigated that blade shape micropillars with 0.150 mm gaps deliver best results compared to the other cases with maximum and minimum values of the mixing index 0.95 and 0.72 respectively. The obtained results can be extremely helpful for design and modifications of hybrid microfluidics micro-mixer.

8 December 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
MWMuhammad Waqas
Muhammad Waqas
APArvydas Palevicius
Arvydas Palevicius
CŞCengizhan Ömer Şenol
Cengizhan Ömer Şenol
Giedrius JanusasGiedrius Janusas
Giedrius Janusas
Microfluidics is considered a revolutionary interdisciplinary technology with substantial interest in various biomedical applications. Many non-Newtonian fluids often used in microfluidics systems are notably influenced by the external active fields, such as acoustic, electric, and magnetic fields, leading to changes in rheological behavior. In this study, a numerical investigation is carried out to explore the rheological behavior of non-Newtonian fluids in a T-shaped microfluidics channel integrated with complex micropillar structures under the influence of acoustic, electric, and magnetic fields. For this purpose, COMSOL Multiphysics with laminar flow, pressure acoustic, electric current, and magnetic field physics is used to examine rheological characteristics of non-Newtonian fluids. Three polymer solutions, such as 2000 ppm xanthan gum (XG), 1000 ppm polyethylene oxide (PEO), and 1500 ppm polyacrylamide (PAM), are used as a non-Newtonian fluids with the Carreau–Yasuda fluid model to characterize the shear-thinning behavior. Moreover, numerical simulations are carried out with different input parameters, such as Reynolds numbers (0.1, 1, 10, and 50), acoustic pressure (5 Mpa, 6.5 Mpa, and 8 Mpa), electric voltage (200 V, 250 V, and 300 V), and magnetic flux (0.5 T, 0.7 T, and 0.9 T). The findings reveal that the incorporation of active fields and micropillar structures noticeably impacts fluid rheology. The acoustic field induces higher shear-thinning behavior, decreasing dynamic viscosity from 0.51 Pa·s to 0.34 Pa·s. Similarly, the electric field induces higher shear rates, reducing dynamic viscosities from 0.63 Pa·s to 0.42 Pa·s, while the magnetic field drops the dynamic viscosity from 0.44 Pa·s to 0.29 Pa·s. Additionally, as the Reynolds number increases, the shear rate also rises in the case of electric and magnetic fields, leading to more chaotic flow, while the acoustic field advances more smooth flow patterns and uniform fluid motion within the microchannel. Moreover, a proposed experimental framework is designed to study non-Newtonian fluid mixing in a T-shaped microfluidics channel under external active fields. Initially, the microchannel was fabricated using a high-resolution SLA printer with clear photopolymer resin material. Post-processing involved analyzing particle distribution, mixing quality, fluid rheology, and particle aggregation. Overall, the findings emphasize the significance of considering the fluid rheology in designing and optimizing microfluidics systems under active fields, especially when dealing with complex fluids with non-Newtonian characteristics.

25 April 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
MHMuhammad Ali Hashmi
Muhammad Ali Hashmi
APArvydas Palevicius
Arvydas Palevicius
SUSigita Urbaite
Sigita Urbaite
Giedrius JanusasGiedrius Janusas
Giedrius Janusas
MWMuhammad Waqas
Muhammad Waqas
Today, microfluidics has become a revolutionary field of engineering due to its wide range of applications, including lab-on-a-chip devices, microscale biochemical reactors, drug delivery systems, and disease diagnostics. Efficient fluid mixing has been a significant challenge in these systems due to the dominance of laminar flow and low-Reynolds number conditions, where mixing relies primarily on slow molecular diffusion. It is very difficult to achieve rapid mixing and homogeneous mixing within a limited length. In this study, a bioinspired passive micromixer is developed based on the cristae architecture of mitochondria, which is known for maximizing surface area and transport efficiency in biological systems. The micromixer incorporates cristae-like microstructures within a straight microchannel to produce continuous flow deflection, stretching, and folding, thereby promoting chaotic advection without relying on external energy sources. It also includes mitochondrial granules, such as micropillars, within the channel to disrupt streamline flow. Thus, a numerical investigation was conducted to design four different micromixer geometries: conventional T-channel, and T-channels with a single, double and triple matrix of cristae. The analysis was performed in COMSOL Multiphysics, in which “Laminar flow” and “Transport of diluted species” physics were used, and a stationary study was executed. Simulations were conducted at different Reynolds numbers (Re = 0.1–100) to observe the feasibility of the proposed designs. For analysis, the mixing index and concentration profiles at the outlet and along the length were also examined. The results showed that the high cristae density channel performed well, achieving a mixing index of 95.85% at Re = 0.1 and 85.84% at Re = 100, proving that the proposed mitochondria-inspired cristae Mito-mixer delivers efficient mixing over a broad Reynolds-number range while maintaining a compact, length-efficient design.

1 January 2025
Verified
Conference Paper
Open access
PDF file
MWMuhammad Waqas
Muhammad Waqas
APArvydas Palevicius
Arvydas Palevicius
This work presents the numerical investigation of three different microfluidics micromixer designs integrated with screw element and complex shape micropillar structure as a passive element. For this purpose, COMSOL Multiphysics with two physics such as laminar flow and transport diluted species to examine the fluid flow and mixing behavior inside a microchannel. The results revealed that the third micromixer design integrated with screw element and complex shape micropillar structures deliver a best mixing efficiency of 99.95% at Reynold numbers 1. In addition, the pressure drop from inlet to outlet is also examined that is 31.26502 Pa. The findings obtained from this study provide deep insights to examine the optimal micromixer design with larger mixing performance and lower pressure drop.