Objective. Increasing complexity in extracellular stimulation experiments and neural implant design also requires realistic computer simulations capable of modeling the neural activity of nerve cells under the influence of an electrical stimulus. Classical model approaches are often based on simplifications, are not able to correctly calculate the electric field generated by complex electrode designs, and do not consider electrical effects of the cell on its surrounding. A more accurate approach is the finite element method (FEM), which provides necessary techniques to solve the Poisson equation for complex geometries under consideration of electrical tissue properties. Especially in situations where neurons experience large and non-symmetric extracellular potential gradients, a FEM solution that implements the cell membrane model can improve the computer simulation results. To investigate the response of neurons in an electric field generated by complex electrode designs, a FEM framework for extracellular stimulation was developed in COMSOL. Approach. Methods to implement morphologically- and biophysically-detailed neurons including active Hodgkin-Huxley (HH) cell membrane dynamics as well as the stimulation setup are described in detail. Covered methods are (a) development of cell and electrode geometries including meshing strategies, (b) assignment of physics for the conducting spaces and the realization of active electrodes, (c) implementation of the HH model, and (d) coupling of the physics to get a fully described model. Main results. Several implementation examples are briefly presented: (a) a full FEM implementation of a HH model cell stimulated with a honeycomb electrode, (b) the electric field of a cochlear electrode placed inside the cochlea, and (c) a proof of concept implementation of a detailed double-cable cell membrane model for myelinated nerve fibers. Significance. The presented concepts and methods provide basic and advanced techniques to realize a full FEM framework for innovative studies of neural excitation in response to extracellular stimulation.
Microwave ablation (MWA) of liver tumors presents challenges like under- and over-ablation, potentially leading to inadequate tumor destruction and damage to healthy tissue. This study aims to develop personalized three-dimensional (3D) models to simulate MWA for liver tumors, incorporating patient-specific characteristics. The primary objective is to validate the predicted ablation zones compared to clinical outcomes, offering insights into MWA before therapy to facilitate accurate treatment planning. Contrast-enhanced CT images from three patients were used to create 3D models. The simulations used coupled electromagnetic wave propagation and bioheat transfer to estimate the temperature distribution, predicting tumor destruction and ablation margins. The findings indicate that prolonged ablation does not significantly improve tumor destruction once an adequate margin is achieved, although it increases tissue damage. There was a substantial overlap between the clinical ablation zones and the predicted ablation zones. For patient 1, the Dice score was 0.73, indicating high accuracy, with a sensitivity of 0.72 and a specificity of 0.76. For patient 2, the Dice score was 0.86, with a sensitivity of 0.79 and a specificity of 0.96. For patient 3, the Dice score was 0.8, with a sensitivity of 0.85 and a specificity of 0.74. Patient-specific 3D models demonstrate potential in accurately predicting ablation zones and optimizing MWA treatment strategies.
Objective. The cochlear implant (CI) belongs to the most successful neuro-prostheses. Traditionally, the stimulating electrode arrays are inserted into the scala tympani (ST), the lower cochlear cavity, which enables simple surgical access. However, often deep insertion is blocked, e.g. by ossification, and the auditory nerve fibers (ANFs) of lower frequency regions cannot be stimulated causing severe restrictions in speech understanding. As an alternative, the CI can be inserted into the scala vestibuli (SV), the other upper cochlear cavity. Approach. In this computational study, the excitability of 25 ANFs are compared for stimulation with ST and SV implants. We employed a 3-dimensional realistic human cochlear model with lateral wall electrodes based on a μ-CT dataset and manually traced fibers. A finite element approach in combination with a compartment model of a spiral ganglion cell was used to simulate monophasic stimulation with anodic (ANO) and cathodic (CAT) pulses of 50 μs. Main results. ANO thresholds are lower in ST (mean/std = μ/σ = 189/55 μA) stimulation compared to SV (μ/σ = 323/119 μA) stimulation. Contrary, CAT thresholds are higher for the ST array (μ/σ = 165/42 μA) compared to the SV array (μ/σ = 122/46 μA). The threshold amplitude depends on the specific fiber-electrode spatial relationship, such as lateral distance from the cochlear axis, the angle between electrode and target ANF, and the curvature of the peripheral process. For CAT stimulation the SV electrodes show a higher selectivity leading to less cross-stimulation of additional fibers from different cochlear areas. Significance. We present a first simulation study with a human cochlear model that investigates an additional CI placement into the SV and its impact on the excitation behavior. Results predict comparable outcomes to ST electrodes which confirms that SV implantation might be an alternative for patients with a highly obstructed ST.