Nose-to-brain (N2B) drug delivery is a promising technique for the treatment of brain diseases. It allows a drug to enter the brain without passing through the blood–brain barrier. However, the nasal cavity and nasal mucosa can restrict the amount of drug absorbed. Recent studies of non-thermal plasma (NTP) have shown improvement in in vitro drug delivery to cells and tissues. However, whether NTP treatments can enhance the in vivo delivery of drugs for neurodegenerative disease like Alzheimer’s disease (AD) into the brain via the N2B technique remains unclear. The drug used in this study was galantamine hydrobromide. Galantamine is used to treat patients with mild to moderate AD. Based on the principle of NTP, a type of dielectric barrier discharge (DBD) plasma, which we called spiral DBD microplasma, was designed. It was inserted into the nose of a rat to a depth of 2 mm. The spiral DBD microplasma was driven by a sinusoidal voltage for 4 min, followed by the immediate administration of galantamine. The effect of the microplasma treatment on the distribution of galantamine in the brain was evaluated using matrix-assisted laser desorption/ionization-imaging mass spectrometry (MALDI-IMS). The results showed a high distribution of galantamine in the left and right brain hemispheres of the rat treated with plasma discharge compared to a control treated without plasma discharge. The spiral DBD microplasma is a novel contribution to DBD plasma designs. In addition, this technique for drug delivery has also created a novel approach with potential for becoming a non-invasive method of enhancing drug distribution in the brain for the treatment of neurological disorders.
Microplasma irradiation is a promising technique for the transdermal delivery of high-molecular-weight drugs. In this technique, microplasma components interact with the skin surface or cell membranes, allowing the drugs to penetrate. For efficient and safe drug delivery, it is crucial to understand these interactions. To this end, this study investigated the effects of microplasma irradiation on cellular lipids, particularly those associated with cell membranes. Rat intestinal epithelial cells were treated with microplasma irradiation at two different voltages (4.0 kV or 4.5 kV). An untargeted lipidomic was conducted using liquid chromatography–mass spectrometry (LC/MS) technique. The results revealed that microplasma irradiation at 4.0 kV induces a significant increase in cell membrane lipids within 10 min post-irradiation. All major cell membrane lipids, including phosphatidylcholine, phosphatidylethanolamine, phosphatidylserine, and sphingomyelin, exhibited increases of over 25% within this short timeframe. Notably, this effect is transient, as lipid levels return to their baseline after 12 h. Furthermore, no significant differences in live and apoptotic cell percentages were observed between the control and 12 h post-irradiated cells. In contrast, irradiation at 4.5 kV did not elicit significant changes in cell membrane lipids, correlating with the absence of drug absorption under this condition. Hence, our study unveiled a correlation between the rapid increase in cell membrane lipids and enhanced drug absorption in microplasma-irradiated cells. This lipid augmentation potentially enhances membrane fluidity and permeability, thus facilitating drug absorption. Beyond elucidating the mechanisms and safety of microplasma-based drug delivery, our research provides valuable insights for advancing various microplasma-based biomedical technologies.
This study explores the potential of cold atmospheric plasma (CAP) to facilitate the delivery of large-molecule drugs to the brain. The blood–brain barrier (BBB) restricts the passage of most drugs, hindering treatment for neurological disorders. CAP generates reactive oxygen and nitrogen species (RONS) that may disrupt the BBB’s tight junctions, potentially increasing drug permeability. An in vitro BBB model and an immortalized cell line (bEND.3) were used in this experiment. Fluorescein isothiocyanate dextran (FD-4), a model drug, was added to the cells to determine drug permeability. Custom microplasma was used to produce reactive oxygen species (ROS). Trans-endothelial electrical resistance (TEER) measurements assessed the integrity of the BBB after the CAP treatment. A decrease in TEER was observed in the CAP-treated group compared to the controls, suggesting increased permeability. Additionally, fluorescence intensity measurements from the basal side of the trans-well plate indicated higher drug passage in the CAP-treated group. Moreover, the higher presence of ROS in the plasma-treated cells confirmed the potential of CAP in drug delivery. These findings suggest that CAP may be a promising approach for enhancing brain drug delivery.
The blood–brain barrier (BBB) limits drug delivery to the brain, particularly for large or hydrophilic molecules. Brain microvascular endothelial cells (bEND.3), which form part of the BBB, play a critical role in regulating drug uptake. This study investigates the use of cold atmospheric microplasma (CAM) to enhance membrane permeability and facilitate drug delivery in bEND.3 cells. CAM generates reactive oxygen species (ROS) that modulate membrane properties. We exposed bEND.3 cells to CAM at varying voltages (3, 3.5, 4, and 4.5 kV) and measured drug uptake using the fluorescent drug FD-150, fluorescence intensity, ROS levels, membrane lipid order, and membrane potential. The results showed a significant increase in fluorescence intensity and drug concentration in the plasma-treated cells compared to controls. ROS production, measured by DCFH-DA staining, was higher in the plasma-treated cells, supporting the hypothesis that CAM enhances membrane permeability through ROS-induced changes. Membrane lipid order, assessed using the LipiORDER probe, shifted from the liquid-ordered (Lo) to liquid-disordered (Ld) phase, indicating increased membrane fluidity. Membrane depolarization was detected with DisBAC2(3) dye, showing increased fluorescence in the plasma-treated cells. Cell viability, assessed by trypan blue and LIVE/DEAD™ assays, revealed transient damage at higher voltages (≥4 kV), with recovery after 24 h. These results suggest that CAM enhances drug delivery in bEND.3 cells by modulating membrane properties via ROS production and changes in membrane potential. CAM offers a promising strategy for improving drug delivery to the brain, with potential applications in brain-targeted therapies.
Low temperature plasmas (LTPs) generated at atmospheric pressure and room temperature have gained increasing attention in biomedical research due to their ability to control cellular behavior through the production of reactive oxygen and nitrogen species (RONS), electric fields, and UV radiation. Among several LTP configurations, dielectric barrier discharge (DBD) plasma has been extensively studied for its ability to stimulate controlled biological effects while maintaining low gas temperature, making it suitable for cell-based applications. This study designed a novel spiral-wound DBD plasma device to investigate the voltage-dependent effects of plasma discharge on DBC1.2 epithelial cells. Plasma was applied at 2 kVp-p, 3 kVp-p, and 4 kVp-p to evaluate its effect on cellular permeability, mitochondrial activity, viability, and apoptosis. FITC-dextran-70 (FD-70, MW: 70 kDa) was used as a model permeation marker to assess cellular uptake. The results showed a voltage-dependent increase in FD-70 uptake, suggesting improved plasma-assisted drug delivery. The cell mitochondrial activity, evaluated with a MT-1 MitoMP detection kit, revealed that plasma exposure at 2 kVp-p and 3 kVp-p slightly enhanced mitochondrial membrane potential (MMP), signifying increased metabolic and mitochondrial activity, whereas exposure at 4 kVp-p led to a reduction in MMP, suggesting oxidative stress and early apoptosis. Early and late apoptosis was further assessed using FITC Annexin-V and propidium iodide (PI). The results showed enhanced cell viability and a reduced apoptotic cell at 2 kVp-p and 3 kVp-p plasma exposure when compared to the control. However, at 4 kV, there was a decline in cell viability and an increase in apoptosis, suggesting a shift towards plasma-induced cytotoxicity. This study established a safe plasma exposure threshold for DBC1.2 cells and explored the potential use of a spiral-wound DBD plasma device for biomedical applications, particularly in drug delivery and cell modulation.
Cellular senescence plays a pivotal role in aging and stress response mechanisms. Controlling cellular senescence is essential for developing novel techniques to prevent aging or aging-related diseases and promote a healthy lifespan. This study explores the efficiency of cold atmospheric microplasma (CAM) for controlling cellular senescence in yeast Saccharomyces cerevisiae. Reactive oxygen and nitrogen species (RONS) generated by CAM influence key processes, such as the regulation of oxidative stress, alterations in membrane potential, and senescence-related epigenetic modifications. As a marker of cellular senescence, the expression of β-galactosidase was assessed in response to different plasma treatments. At a frequency of 1 kHz and a discharge voltage of 5 kVp-p, a significant reduction in β-galactosidase activity was observed in cells treated for 10 s and 30 s compared to the control, indicating a reduction in cellular senescence. Additionally, cell viability, metabolic activity, and plasma membrane potential were also found to be higher for the treated cells compared to the control under the same conditions. This study confirms that a physiologically tolerable level of ROS and RNS is sufficient for cellular signaling, but not for damage induction. The findings from this study provide insights on the potential of microplasma as a tool for controlling cellular senescence and the development of therapeutic innovations involving eukaryotic cells.