Zygmunt Szefliński

Mr. Zygmunt Szefliński

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MMMonika Mietelska
Monika Mietelska
MPMarcin Pietrzak
Marcin Pietrzak
ABAleksandr Bancer
Aleksandr Bancer
ARAntoni Rucinski
Antoni Rucinski
ZSZygmunt Szefliński
Zygmunt Szefliński
BBBeata Brzozowska
Beata Brzozowska
Details of excitation and ionization acts hide a description of the biological effects of charged particle traversal through living tissue. Nanodosimetry enables the introduction of novel quantities that characterize and quantify the particle track structure while also serving as a foundation for assessing biological effects based on this quantification. This presents an opportunity to enhance the planning of charged particle radiotherapy by taking into account the ionization detail. This work uses Monte Carlo simulations with Geant4-DNA code for a wide variety of charged particles and their radiation qualities to analyze the distribution of ionization cluster sizes within nanometer-scale volumes, similar to DNA diameter. By correlating these results with biological parameters extracted from the PIDE database for the V79 cell line, a novel parameter R2 based on ionization details is proposed for the evaluation of radiation quality in terms of biological consequences, i.e., radiobiological cross section for inactivation. By incorporating the probability p of sub-lethal damage caused by a single ionization, we address limitations associated with the usually proposed nanodosimetric parameter Fk for characterizing the biological effects of radiation. We show that the new parameter R2 correlates well with radiobiological data and can be used to predict biological outcomes.

4 September 2025 in Environmental and Experimental Botany
Verified
Journal Article
Open access
GWGrzegorz Wałpuski
Grzegorz Wałpuski
ARAndrzej Rafalski
Andrzej Rafalski
MGMarta Galas
Marta Galas
ZSZygmunt Szefliński
Zygmunt Szefliński
MZMaksymilian Zienkiewicz
Maksymilian Zienkiewicz

1 June 2024 in Polish Journal of Medical Physics And Engineering
Verified
Journal Article
Open access
PDF file
MFMateusz Filipek
Mateusz Filipek
BPBeata Pszczółkowska
Beata Pszczółkowska
BKBartłomiej Kociński
Bartłomiej Kociński
MSMarta Senkowska
Marta Senkowska
ZSZygmunt Szefliński
Zygmunt Szefliński
BBBeata Brzozowska
Beata Brzozowska
Introduction: Proton radiotherapy offers an advantage in sparing healthy tissue compared to photon therapy due to the specific interaction of protons with the patient’s body. In radiobiological experiments, alpha sources are commonly used instead of proton accelerators for convenience, but ensuring a uniform dose distribution is challenging. Properly designing the cell irradiation setup is crucial to reliably measure the average cellular response in such experiments. The objective of this research is to underscore the importance of dosimetric validation in radiobiological investigations. While Monte Carlo (MC) simulations offer valuable insights, their accuracy needs experimental confirmation. Once consistent results are obtained, the reliance on simulations becomes viable, as they are more efficient and less cumbersome compared to experimental procedures. Material and methods: The simulations are performed with three MC code-based tools: Geant4-DNA, GATE, and SRIM to model the alpha radiation source and calculate dose distributions for various cell irradiation scenarios. Dosimetric verification of the experimental setup containing a 241 Am source is performed using radiochromic films. Additionally, a clonogenic cell survival assay is carried out for the DU145 cell line. Results: The study introduces a novel source simulation model derived from dosimetric measurements. The comparison between dosimetric results obtained with simulations and measured experimentally yields a gamma (3%/3mm) parameter value exceeding 99%. Furthermore, the LQ model parameters fitted to survival data of DU145 cells irradiated with particles emitted from 241 Am source demonstrate consistency with previously published findings. Conclusions: Radiobiological experiments investigate cellular responses to various irradiation scenarios. Challenges arise with densely ionizing radiation used in clinical practice, particularly in ensuring uniform dose delivery for reliable experiments. MC codes aid in simulating dose distribution and designing irradiation systems for consistent cell treatment. However, experimental validation is essential before relying on simulation results. Once confirmed, these results offer a cost-effective and time-efficient approach to planning radiobiological experiments compared to traditional laboratory work.