Antoni Rucinski

Dr. Antoni Rucinski

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
KDKamil Dulski
Kamil Dulski
NCNeha Chug
Neha Chug
CCCatalina Curceanu
Catalina Curceanu
ECEryk Czerwiński
Eryk Czerwiński
WWWojciech Wiślicki
Wojciech Wiślicki
Positronium created in a human body during PET scans hallmarks neoplastic tissues.

8 September 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DSDavid Sarrut
David Sarrut
NANicolas Arbor
Nicolas Arbor
TBThomas Baudier
Thomas Baudier
DBDamian Borys
Damian Borys
AEAne Etxebeste
Ane Etxebeste
LMLydia Maigne
Lydia Maigne
This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. Based on the shoulders of Geant4, the principal modules (geometry, physics, scorers) are described with brief descriptions of some key concepts (Volume, Actors, Digitizer). The main source code repositories are detailed together with the automated compilation and tests processes (Continuous Integration). We then described how the OpenGATE collaboration managed the collaborative development of about one hundred developers during almost 20 years. The impact of GATE on medical physics and cancer research is then summarized, and examples of a few key applications are given. Finally, future development perspectives are indicated.

21 January 2021 in Frontiers in Physics
Verified
Journal Article
Open access
JGJan Gajewski
Jan Gajewski
MGMagdalena Garbacz
Magdalena Garbacz
CCChih-Wei Chang
Chih-Wei Chang
KCKatarzyna Czerska
Katarzyna Czerska
MDMarco Durante
Marco Durante
ARAntoni Rucinski
Antoni Rucinski
We present commissioning and validation of Fred, a graphical processing unit (GPU)–accelerated Monte Carlo code, for two proton beam therapy facilities of different beam line design: CCB (Krakow, IBA) and EMORY (Atlanta, Varian). We followed clinical acceptance tests required to approve the certified treatment planning system for clinical use. We implemented an automated and efficient procedure to build a parameter library characterizing the clinical proton pencil beam. Beam energy, energy spread, lateral propagation model, and a dosimetric calibration factor were parametrized based on measurements performed during the facility start-up. The Fred beam model was validated against commissioning and supplementary measurements performed with and without range shifter. We obtained 1) submillimeter agreement of Bragg peak shapes in water and lateral beam profiles in air and slab phantoms, 2) <2% dose agreement for spread out Bragg peaks of different ranges, 3) average gamma index (2%/2 mm) passing rate of >95% for >1000 patient verification measurements using a two-dimensional array of ionization chambers, and 4) gamma index passing rate of >99% for three-dimensional dose distributions computed with Fred and measured with an array of ionization chambers behind an anthropomorphic phantom. The results of example treatment planning study on >100 patients demonstrated that Fred simulations in computed tomography enable an accurate prediction of dose distribution in patient and application of Fred as second patient quality assurance tool. Computation of a patient treatment in a CT using 104 protons per pencil beam took on average 2′30 min with a tracking rate of 2.9× 105 p+/s. Fred was successfully commissioned and validated against the clinical beam model, showing that it could potentially be used in clinical routine. Thanks to high computational performance due to GPU acceleration and an automated beam model implementation method, the application of Fred is now possible for research or quality assurance purposes in most of the proton facilities.

1 February 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CGCarlos Granja
Carlos Granja
COCristina Oancea
Cristina Oancea
JJJan Jakubek
Jan Jakubek
LMLukas Marek
Lukas Marek
EBEric Benton
Eric Benton
PKPavel Krist
Pavel Krist

8 May 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PSPaulina Stasica
Paulina Stasica
HNHanh Nguyen
Hanh Nguyen
CGCarlos Granja
Carlos Granja
RKRenata Kopec
Renata Kopec
LMLukas Marek
Lukas Marek
JGJan Gajewski
Jan Gajewski
Objective. Protons have advantageous dose distributions and are increasingly used in cancer therapy. At the depth of the Bragg peak range, protons produce a mixed radiation field consisting of low- and high-linear energy transfer (LET) components, the latter of which is characterized by an increased ionization density on the microscopic scale associated with increased biological effectiveness. Prediction of the yield and LET of primary and secondary charged particles at a certain depth in the patient is performed by Monte Carlo simulations but is difficult to verify experimentally. Approach. Here, the results of measurements performed with Timepix detector in the mixed radiation field produced by a therapeutic proton beam in water are presented and compared to Monte Carlo simulations. The unique capability of the detector to perform high-resolution single particle tracking and identification enhanced by artificial intelligence allowed to resolve the particle type and measure the deposited energy of each particle comprising the mixed radiation field. Based on the collected data, biologically important physics parameters, the LET of single protons and dose-averaged LET, were computed. Main results. An accuracy over 95% was achieved for proton recognition with a developed neural network model. For recognized protons, the measured LET spectra generally agree with the results of Monte Carlo simulations. The mean difference between dose-averaged LET values obtained from measurements and simulations is 17%. We observed a broad spectrum of LET values ranging from a fraction of keV μm−1 to about 10 keV μm−1 for most of the measurements performed in the mixed radiation fields. Significance. It has been demonstrated that the introduced measurement method provides experimental data for validation of LETD or LET spectra in any treatment planning system. The simplicity and accessibility of the presented methodology make it easy to be translated into a clinical routine in any proton therapy facility.

3 August 2016 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
SMSilvia Muraro
Silvia Muraro
GBGiuseppe Battistoni
Giuseppe Battistoni
FCFrancesco Collamati
Francesco Collamati
ELErika De Lucia
Erika De Lucia
RFRiccardo Faccini
Riccardo Faccini
VPVincenzo Patera
Vincenzo Patera
The interaction of the incoming beam radiation with the patient body in hadrontherapy treatments produces secondary charged and neutral particles, whose detection can be used for monitoring purposes and to perform an on-line check of beam particle range. In the context of ion-therapy with active scanning, charged particles are potentially attractive since they can be easily tracked with a high efficiency, in presence of a relatively low background contamination. In order to verify the possibility of exploiting this approach for in-beam monitoring in ion-therapy, and to guide the design of specific detectors, both simulations and experimental tests are being performed with ion beams impinging on simple homogeneous tissue-like targets (PMMA). From these studies, a resolution of the order of few millimeters on the single track has been proven to be sufficient to exploit charged particle tracking for monitoring purposes, preserving the precision achievable on longitudinal shape. The results obtained so far show that the measurement of charged particles can be successfully implemented in a technology capable of monitoring both the dose profile and the position of the Bragg peak inside the target and finally lead to the design of a novel profile detector. Crucial aspects to be considered are the detector positioning, to be optimized in order to maximize the available statistics, and the capability of accounting for the multiple scattering interactions undergone by the charged fragments along their exit path from the patient body. The experimental results collected up to now are also valuable for the validation of Monte Carlo simulation software tools and their implementation in Treatment Planning Software packages.