Healthcare institutions are progressively integrating artificial intelligence (AI) into their operations. The extraordinary potential of AI is restricted by insufficient medical data for AI model training and adversarial attacks wherein attackers perturb the dataset by adding some noise to it, which leads to the malfunctioning of the AI models, and a lack of trust caused by the opaque operational approach it employs. This Systematic Literature Review (SLR) is a state‐of‐the‐art survey of the research on blockchain technology for securing AI‐integrated healthcare applications. The most relevant articles from the Scopus and Web of Science (WoS) databases were identified using the PRISMA model. Most of the existing literature is about protecting the healthcare data used by AI‐based healthcare systems using blockchain technology, but the modality of data (text, images, audio, and sound) was not specifically mentioned. Information on protecting the training phase and model deployment for AI‐based healthcare systems considering the variations in feature extraction based on the modality of data was also not clearly specified. Hence, the three subfields of AI, namely, natural language processing (NLP), computer vision, and acoustic AI are further studied to identify security loopholes in its implementation pipeline. The three phases, namely the dataset, the training phase, and the trained models need to be protected from adversaries to avoid malfunctioning of the deployed AI models. The nature of the data processed by NLP, computer vision, and acoustic AI, underlying deep neural network (DNN) architectures, the complexity of attacks, and the perceivability of attacks by humans are analyzed to identify the need for security. A blockchain solution for AI‐based healthcare systems is synthesized based on the findings that have demonstrated the distinctive technological features of blockchains. It offers a solution for the privacy and security issues encountered by NLP, computer vision, and acoustic AI to boost the widespread adoption of AI applications in healthcare.
14 November 2023 in Interdisciplinary Sciences: Computational Life Sciences
As one of the most common female cancers, cervical cancer often develops years after a prolonged and reversible pre-cancerous stage. Traditional classification algorithms used for detection of cervical cancer often require cell segmentation and feature extraction techniques, while convolutional neural network (CNN) models demand a large dataset to mitigate over-fitting and poor generalization problems. To this end, this study aims to develop deep learning models for automated cervical cancer detection that do not rely on segmentation methods or custom features. Due to limited data availability, transfer learning was employed with pre-trained CNN models to directly operate on Pap smear images for a seven-class classification task. Thorough evaluation and comparison of 13 pre-trained deep CNN models were performed using the publicly available Herlev dataset and the Keras package in Google Collaboratory. In terms of accuracy and performance, DenseNet-201 is the best-performing model. The pre-trained CNN models studied in this paper produced good experimental results and required little computing time. Graphical Abstract
The single-valued neutrosophic set (SVNS) is a well-known model for handling uncertain and indeterminate information. Information measures such as distance measures, similarity measures and entropy measures are very useful tools to be used in many applications such as multi-criteria decision making (MCDM), medical diagnosis, pattern recognition and clustering problems. A lot of such information measures have been proposed for the SVNS model. However, many of these measures have inherent problems that prevent them from producing reasonable or consistent results to the decision makers. In this paper, we propose several new distance and similarity measures for the SVNS model. The proposed measures have been verified and proven to comply with the axiomatic definition of the distance and similarity measure for the SVNS model. A detailed and comprehensive comparative analysis between the proposed similarity measures and other well-known existing similarity measures has been done. Based on the comparison results, it is clearly proven that the proposed similarity measures are able to overcome the shortcomings that are inherent in existing similarity measures. Finally, an extensive set of numerical examples, related to pattern recognition and medical diagnosis, is given to demonstrate the practical applicability of the proposed similarity measures. In all numerical examples, it is proven that the proposed similarity measures are able to produce accurate and reasonable results. To further verify the superiority of the suggested similarity measures, the Spearman’s rank correlation coefficient test is performed on the ranking results that were obtained from the numerical examples, and it was again proven that the proposed similarity measures produced the most consistent ranking results compared to other existing similarity measures.