SANGWON JI

Prof. Dr. SANGWON JI

Department of Mecahnical System Engineering, Pukyong National University, Busan, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2019 in Measurement and Control
Verified
Journal Article
Open access
PDF file
DLDong-Hoon Lee
Dong-Hoon Lee
TKTae-Wan Kim
Tae-Wan Kim
SJSANGWON JI
SANGWON JI
Youngbok KimYoungbok Kim
Youngbok Kim
The main purpose of any crane system is to move a load to a specified place. Accurate load positioning in the presence of unpredictable external factors is an important issue when operating a crane. Attenuation of load vibration during crane operation is immensely critical in order to satisfy rigorous requirements for safety and efficiency. When a crane is installed and operated on a vessel at sea, work conditions become even more difficult and thus require more stringent attention to load positioning and attenuation of load vibration. At sea, this process is complicated due to factors such as waves and wind, making accurate crane operation nearly impossible. For these reasons, active heave compensation systems have been developed to suppress the effects of disturbances raised from the harsh sea environment including vessel motions. This paper explores the suppression method of unexpected vertical vibration of load. Unlike past research on the topic, this research includes rope dynamics in the control system design for suppressing load vibration. In addition, this research considers uncertain disturbances—vessel motions not controlled by any active force that result in undesirable heave motion of a crane. Load motion is indirectly estimated using a load cell because we do not yet have any useful tool to measure it directly. In the considered crane system, two winches were used, one for moving the load and the other for suppressing residual vibration. To evaluate the proposed control strategy and system performance, several control techniques were applied: proportional–integral–derivative control, sliding mode control, and feedback linearization control methods.

15 January 2026 in Actuators
Verified
Journal Article
Open access
PDF file
HYHyunWoo Yang
HyunWoo Yang
Ho Sung JangHo Sung Jang
Ho Sung Jang
SJSANGWON JI
SANGWON JI
External gear pumps are widely used in industrial hydraulic systems, but their volumetric efficiency can deteriorate significantly because of internal leakage, especially under high-pressure operating conditions. Conventional lumped parameter models typically assume fixed clearances and therefore cannot accurately capture the leakage behavior associated with pressure-induced deformation and wear. In this study, a dynamic clearance model for an external gear pump is developed and experimentally validated. Radial and axial clearances are measured in situ using eddy-current gap sensors over a range of operating conditions, and empirical correlation equations are identified as functions of pressure and rotational speed. These correlations are embedded into a tooth-space-volume-based lumped parameter model so that the leakage flow is updated at each time step according to the instantaneous dynamic clearances. The proposed model is validated against experimental measurements of volumetric efficiency obtained from a dedicated test bench. At 800 rev/min, the average prediction error of volumetric efficiency is reduced to 1.98% with the proposed dynamic clearance model, compared with 9.43% for a nominal static-clearance model and 3.35% for a model considering only static wear. These results demonstrate that explicitly accounting for dynamic clearance variations significantly improves the predictive accuracy of volumetric efficiency, and the proposed model can be used as a design tool for optimizing leakage paths and enhancing the energy efficiency of external gear pumps.

Verified
Journal Article
Open access
PDF file
Ho Sung JangHo Sung Jang
Ho Sung Jang
SJSANGWON JI
SANGWON JI
External gear pumps with an involute tooth profile are used in many applications because of their simple shape, low production cost, and excellent reliability. However, they can be characterized by the generation of vibration and noise, due to the pressure pulsation caused by the trapped volume resulting from the gear meshing. In this study, a one-point continuous contact helical gear pump with circular-involute teeth was designed to eliminate the trapped volume. A novel geometrical approach is described to analyze the kinematic flow of this pump. The morphology of the tooth space, which changes depending on the angular position of the rotating gear, is explained by a newly defined algorithm. Algorithms designed for the geometric approach are simple because they define tooth space morphology for specific angular positions and therefore do not require corrections. The area of tooth space calculated through numerical analysis is used to calculate the instantaneous theoretical flow rate. The kinematic flow rate of the numerically analyzed pump can quantify the compressibility effect of the fluid. In addition, the calculated instantaneous theoretical flow rate accurately reflects the physical characteristics compared to previous studies and can be used to identify the cause of flow ripple.

27 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
JCJi-Ah Choi
Ji-Ah Choi
JJJi-Seong Jang
Ji-Seong Jang
SJSANGWON JI
SANGWON JI
This study presents a method for predicting nozzle surface temperature and the timing of frost formation during hydrogen refueling using machine learning. A continuous refueling system was implemented based on a simulation model that was developed and validated in previous research. Data were collected under various boundary conditions, and eight regression models were trained and evaluated for their predictive performance. Hyperparameter optimization was performed using random search to enhance model performance. The final models were validated by applying boundary conditions not used during model development and comparing the predicted values with simulation results. The comparison revealed that the maximum error rate occurred after the second refueling, with a value of approximately 4.79%. Currently, nitrogen and heating air are used for defrosting and frost reduction, which can be costly. The developed machine learning models are expected to enable prediction of both frost formation and defrosting timings, potentially allowing for more cost-effective management of defrosting and frost reduction strategies.

31 December 2018 in Journal of Power System Engineering
Verified
Journal Article
Closed access
KKKaptae Kim
Kaptae Kim
SSSoosik Shin
Soosik Shin
SJSANGWON JI
SANGWON JI

13 January 2026 in Actuators
Verified
Journal Article
Open access
PDF file
MWManhui Woo
Manhui Woo
SJSANGWON JI
SANGWON JI
Radial piston motors are expected to expand their applications in hydraulic drive systems due to their high torque density and mechanical robustness. However, its volumetric efficiency can be significantly affected by the multi-stroke operating characteristics and leakage occurring in the micro-clearances of the valve plate. In this study, a detailed modeling procedure for a multi-stroke radial piston motor is proposed using the 1D system simulation software Amesim. In particular, the dynamic interaction between the ports and pistons inside the motor is formulated using mathematical function-based expressions, enabling a more precise representation of the driving behavior and torque generation process. Furthermore, to characterize the leakage flow occurring in the micro-clearance between the fluid distributor and cylinder housing, the commercial CFD software Simerics MP+ was employed to analyze the three-dimensional flow characteristics within the leakage gap. Based on these CFD results, a leakage-path function was constructed and implemented in the Amesim model. As a result, the developed model exhibited strong agreement with reference data from an actual motor in terms of overall operating performance, including volumetric and mechanical efficiencies while consistently reproducing the leakage behavior observed in the CFD analysis. The simulation approach presented in this study demonstrates the capability to reliably capture complex fluid–mechanical interactions at the system level, and it can serve as an effective tool for performance prediction and optimal design of hydraulic motors.