16 May 2019 in Measurement and Control
The main purpose of any crane system is to move a load to a specified place. Accurate load positioning in the presence of unpredictable external factors is an important issue when operating a crane. Attenuation of load vibration during crane operation is immensely critical in order to satisfy rigorous requirements for safety and efficiency. When a crane is installed and operated on a vessel at sea, work conditions become even more difficult and thus require more stringent attention to load positioning and attenuation of load vibration. At sea, this process is complicated due to factors such as waves and wind, making accurate crane operation nearly impossible. For these reasons, active heave compensation systems have been developed to suppress the effects of disturbances raised from the harsh sea environment including vessel motions. This paper explores the suppression method of unexpected vertical vibration of load. Unlike past research on the topic, this research includes rope dynamics in the control system design for suppressing load vibration. In addition, this research considers uncertain disturbances—vessel motions not controlled by any active force that result in undesirable heave motion of a crane. Load motion is indirectly estimated using a load cell because we do not yet have any useful tool to measure it directly. In the considered crane system, two winches were used, one for moving the load and the other for suppressing residual vibration. To evaluate the proposed control strategy and system performance, several control techniques were applied: proportional–integral–derivative control, sliding mode control, and feedback linearization control methods.
14 February 2022 in International Journal of Thermophysics
In this work, the transient responses of a heated infrared (IR) temperature sensor were investigated to improve the reliability of determined target temperatures obtained from IR-based medical thermometers. A medical-grade IR temperature sensor was heated at the lower edge of the sidewall of the sensor. To reduce the uncertainty due to the conversion factor of the thermal detector, the temperature of the target, which was a thermostatted blackbody source, was determined when the observed target temperature and the temperature of the detector coincided during the heating and cooling of the sensor. When the determined target temperature was compared with the blackbody source temperature, it was found that during heating, due to the produced temperature gradient in the sensor, the observed target temperature showed erroneous depressions, resulting in the determined target temperature being considerably lower than the true target temperature. In contrast, the determined target temperature during cooling of the heated sensor was consistent with the tested blackbody source temperatures within the claimed uncertainty at all heating conditions. Therefore, based on the obtained results, it was concluded that temperature measurements using an IR temperature sensor could be carried out with the least uncertainty by determining the target temperature when the observed target and detector temperatures coincided during cooling of the heated sensor.
13 August 2019 in WIT transactions on engineering sciences
The problem of manoeuvring vessels within harbour areas is generating considerable interest in terms of marine cybernetics. The vessel is operated by...