Jacob B Harth

Dr. Jacob B Harth

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2023 in Exercise and Sport Sciences Reviews
Verified
Journal Article
Open access
JHJacob B Harth
Jacob B Harth
LRLisa Renzi-Hammond
Lisa Renzi-Hammond
BHBilly Hammond
Billy Hammond
Visual range is quantified by assessing how far one can see clearly (an ability crucial to many athletes). This ability tends to vary significantly across individuals despite similar personal characteristics. We hypothesize that the primary driver of these differences is the individual response to scattered short-wave light in the environment moderated by the dietarily derived retinal pigments lutein and zeaxanthin.

10 March 2026 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
JHJacob B Harth
Jacob B Harth
LRLisa Renzi-Hammond
Lisa Renzi-Hammond
SSSpencer Fleming Smith
Spencer Fleming Smith
BHBilly Hammond
Billy Hammond
Purpose Atmospheric short-wave scattered light (blue haze) limits visual range by reducing the contrast of distant objects. While theoretical models and prior research suggest that filtering short wavelengths can improve visual range, significant individual differences persist in tolerance to veiling luminance, even among individuals with similar ocular health and acuity. This study examined whether a commercially available blue-light filtering (BLF) lens design could enhance visual range under simulated blue haze conditions in an older pseudophakic population. Methods Forty older pseudophakic adults (M = 71.15 ± 5.82 years) were tested using a randomized, controlled, cross-over design. Visual range was assessed via a custom two-channel optical system presenting a sinusoidal grating target veiled by adjustable blue haze (Correlated Color Temperature = 9424 K). Participants viewed the target through a clear control lens and a test BLF lens in randomized order. Visual range thresholds, defined as the maximum blue haze energy tolerated before target detection failed, were determined using the psychophysical method of limits. Results Participants tolerated significantly greater (U = 1035.00; p = 0.024) average blue haze energy with the BLF lens (3.49 log relative energy [LRE]) than with the clear control lens (3.43 LRE). On average, the BLF lens allowed participants to withstand approximately 19% more veiling luminance before target obscuration. Conclusions Consistent with theoretical predictions and prior findings in younger adults, BLF lens designs significantly enhanced visual range in older pseudophakic participants under simulated blue haze conditions. These findings suggest that BLF lenses may offer functional visual benefits in older adults, especially in populations with intraocular lens implants lacking native blue-light filtration. Future research should extend these results using field studies in outdoor environments.

11 October 2026 in Vision
Verified
Journal Article
Open access
PDF file
JNJeffrey Nightingale
Jeffrey Nightingale
CWCameron Wysocky
Cameron Wysocky
JHJacob B Harth
Jacob B Harth
LRLisa Renzi-Hammond
Lisa Renzi-Hammond
BHBilly Hammond
Billy Hammond
Macular pigments (MP; lutein, zeaxanthin, and meso-zeaxanthin) filter short-wavelength light and have been linked to reduced glare and enhanced visual performance. Whether macular pigment optical density (MPOD) is associated with contrast sensitivity (CS) under conditions of minimal MP absorption remains unclear. Fifty-two adults (mean age = 23.5 ± 8.0 years; range = 18–58 years; 85% < 25 years) participated. MPOD was measured using customized heterochromatic flicker photometry. CS was assessed monocularly in the same eye at five spatial frequencies (1.6, 3.2, 8, 16, and 24 cycles/degree), using a custom optical system with narrowband 520 nm laser stimuli. No significant correlations were found between MPOD and CS at any spatial frequency (all |r| ≤ 0.08, all p ≥ 0.59), including when individual area estimates were made for each participant’s curve (area under the logged CSF). Separate partial correlations controlling for iris lightness or habitual visual correction were also non-significant. Although MP has been shown to be related to CS when measured under glare or blue haze conditions, these findings suggest that when filtering by MP is minimized, direct effects on CS, especially on the young healthy eye, are likely minimal.

1 January 2026 in Journal of Ophthalmology
Verified
Journal Article
Open access
BHBilly Hammond
Billy Hammond
JHJacob B Harth
Jacob B Harth
Yaw BuabengYaw Buabeng
Yaw Buabeng
LRLisa Renzi-Hammond
Lisa Renzi-Hammond
Purpose: Several studies have suggested that blue‐light filtering (BLF) can enhance the perception of brightness. Evidence for this effect, however, in pseudophakic patients, particularly using natural images, is lacking. The present study tested whether a common BLF spectral profile, often used in intraocular lens (IOL) designs, would influence brightness perception of natural images in pseudophakic individuals. Methods: Forty pseudophakic participants ( M = 71.15 ± 2.27 years) with 20/40 or better best‐corrected visual acuity implanted with clear IOL implants completed a brightness matching task. Participants viewed a series of natural images through both a clear extraocular filter and a BLF test lens. The test lens was designed to approximate a typical BLF IOL transmission profile. Filter conditions were counterbalanced and randomized. Participants adjusted a short‐wave deficient comparison field until the natural scene and the comparison fields were perceived as equally bright. Matched luminance values (log relative energy, LRE) were recorded across six trials per image. Images were achromatic or short‐, mid‐, and long‐wave dominant. Results: Averaged across all images, the clear lens ( = 2.74 ± 0.14) resulted in significantly lower ( t [78] = −2.529, p = 0.007) LRE values compared to the BLF test lens ( = 2.82 ± 0.15) indicating a modest (∼17%) increase in perceived brightness with the BLF lens. This effect was observed for four of five natural images tested and was not dependent on image contrast or chromatic content. Conclusions: The BLF produced a significant and consistent increase in perceived brightness in pseudophakic adults. These findings provide direct psychophysical evidence that clinically relevant BLF profiles can influence brightness under natural viewing conditions. Information of this type is necessary for the evaluation of BLF IOL designs and their effects on functional visual experiences following cataract surgery.

23 April 2025 in Inventions
Verified
Journal Article
Open access
PDF file
JHJacob B Harth
Jacob B Harth
LRLisa Renzi-Hammond
Lisa Renzi-Hammond
CWCameron J. Wysocky
Cameron J. Wysocky
SSSpencer Fleming Smith
Spencer Fleming Smith
BHBilly Hammond
Billy Hammond
Methodologies to measure motion perception are vital for deepening our understanding of the vision system and the factors that influence it. While existing work has primarily focused on the fastest perceivable velocities, less attention has been paid to the lower threshold of motion (LTM; slowest perceivable velocities). In this study, we designed an optical system to measure LTM in a sample of healthy young adults and to assess the influence of retinal location (central vs. peripheral retina) and stimulus composition (broadband vs. mid-wave) on LTM. The system was based on a xenon light source and a fiber-optic cable that created a bright light stimulus that could be moved along a computer-controlled precision translation slide. The stimulus, exposed for one-second intervals at both a central (fovea) and a peripheral (33 deg) location, was moved at varying speeds to determine the slowest detectable speed. In all, 37 healthy young participants (M = 19.32 ± 1.97 years) were tested. We found substantial between-subject variability in LTM and an interaction between stimulus wavelength and retinal location. The measurement of LTM using this novel apparatus and methodology provides insights into the relationship between slow-moving, ecologically valid stimuli and perceptual detection at the slowest speeds.