Yaw Buabeng

Dr. Yaw Buabeng

Psychology, University of Georgia, Athens, Georgia, USA
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2025 in Experimental Eye Research
Verified
Journal Article
Open access
Yaw BuabengYaw Buabeng
Yaw Buabeng
BHBilly Hammond
Billy Hammond
Macular pigments (MP), composed of lutein, zeaxanthin and meso-zeaxanthin, accumulate in the human fovea and selectively absorb short-wavelength light, potentially influencing spatial vision. This study investigated the relationship between macular pigment optical density (MPOD) and fine spatial resolution across different wavelengths under conditions subject to light scatter. Sixty healthy participants (mean age = 22.7 years) underwent MPOD assessment using heterochromatic flicker photometry and performed a two-point resolution task utilizing a custom optical system with monochromatic and broadband light sources. A significant (p < 0.05) negative correlation was found between MPOD and two-point resolution thresholds at shorter wavelengths but not at longer wavelengths suggesting MP enhances spatial resolution specifically for absorbed wavelengths. Quartile analysis, for example, demonstrated that individuals with higher MPOD exhibited 31-38 % better spatial resolution at 420-540 nm compared to those with lower MPOD. These findings support the hypothesis that MP selectively mitigates light scatter effects and improves visual function even in low-light conditions.

28 September 2026 in Vision
Verified
Journal Article
Open access
PDF file
Yaw BuabengYaw Buabeng
Yaw Buabeng
BHBilly Hammond
Billy Hammond
Clinical relevance: Vernier acuity (VA) is a common clinical metric used to evaluate cortical visual processing and macular health that is relatively independent of typical optical limitations (such as blurring). Background: Past studies have shown that vernier thresholds do not tend to vary according to blur, intensity and spectral content. This last variable, however, is the most inconsistent and has never been measured using relatively narrowband wavelengths. Methods: This study measured vernier thresholds (VT) as a function of wavelength (n = 15) and intensity (n = 5) in healthy young adults (mean age = 24.8 ± 2.3 years) with normal (or near-normal), corrected vision. VTs were tested using backlit apertures. Narrowband stimuli (420–660 nm) and broadband intensities were produced by a 1000 W Xenon arc lamp with interference filters. VTs, defined as the minimum detectable misalignments between two thin rectangular apertures, were recorded using a digital micrometer. Results: VTs did not vary significantly with wavelength (F (6,84) = 1.56, p = 0.17). Similarly, VTs did not vary significantly with the different broadband intensities (F (5,20) = 1.30, p =0.31). Conclusions: The stability of vernier acuity across these conditions indicates that hyperacuity performance is largely invariant to spectral composition and relatively stable across the limited photopic-to-mesopic intensity range that we tested. These findings are consistent with models proposing that vernier acuity depends primarily on post-receptoral neural mechanisms rather than optical or wavelength-dependent retinal factors.

15 July 2025 in Journal of Vision
Verified
Journal Article
Open access
Yaw BuabengYaw Buabeng
Yaw Buabeng
BHBilly Hammond
Billy Hammond
LRLisa Renzi-Hammond
Lisa Renzi-Hammond

1 January 2026 in Journal of Ophthalmology
Verified
Journal Article
Open access
BHBilly Hammond
Billy Hammond
JHJacob B Harth
Jacob B Harth
Yaw BuabengYaw Buabeng
Yaw Buabeng
LRLisa Renzi-Hammond
Lisa Renzi-Hammond
Purpose: Several studies have suggested that blue‐light filtering (BLF) can enhance the perception of brightness. Evidence for this effect, however, in pseudophakic patients, particularly using natural images, is lacking. The present study tested whether a common BLF spectral profile, often used in intraocular lens (IOL) designs, would influence brightness perception of natural images in pseudophakic individuals. Methods: Forty pseudophakic participants ( M = 71.15 ± 2.27 years) with 20/40 or better best‐corrected visual acuity implanted with clear IOL implants completed a brightness matching task. Participants viewed a series of natural images through both a clear extraocular filter and a BLF test lens. The test lens was designed to approximate a typical BLF IOL transmission profile. Filter conditions were counterbalanced and randomized. Participants adjusted a short‐wave deficient comparison field until the natural scene and the comparison fields were perceived as equally bright. Matched luminance values (log relative energy, LRE) were recorded across six trials per image. Images were achromatic or short‐, mid‐, and long‐wave dominant. Results: Averaged across all images, the clear lens ( = 2.74 ± 0.14) resulted in significantly lower ( t [78] = −2.529, p = 0.007) LRE values compared to the BLF test lens ( = 2.82 ± 0.15) indicating a modest (∼17%) increase in perceived brightness with the BLF lens. This effect was observed for four of five natural images tested and was not dependent on image contrast or chromatic content. Conclusions: The BLF produced a significant and consistent increase in perceived brightness in pseudophakic adults. These findings provide direct psychophysical evidence that clinically relevant BLF profiles can influence brightness under natural viewing conditions. Information of this type is necessary for the evaluation of BLF IOL designs and their effects on functional visual experiences following cataract surgery.

29 May 2026 in Attention, Perception, & Psychophysics
Verified
Journal Article
Open access
PDF file
Yaw BuabengYaw Buabeng
Yaw Buabeng
BHBilly Hammond
Billy Hammond
Wavelength influences multiple aspects of visual performance, yet its role in spatial resolution remains incompletely understood due to confounding factors such as luminance differences, chromatic aberration, and intraocular scatter. This study assessed how narrowband light of different wavelengths affects two-point separation thresholds under controlled stimulus and ocular conditions. Action spectra for fine spatial resolution were measured using an equal-energy approach. Sixty healthy young adults (mean age: 22.7 ± 3.3 years) with normal vision were tested in a two-point resolution task. Narrowband stimuli (420–660 nm) and a broadband white condition were produced by a 1,000-W Xenon arc lamp with interference filters. Participants were preselected for optimal acuity. Thresholds, defined as the minimum resolvable separation between two-point sources (two-point separation thresholds), were recorded using a digital micrometer, and converted to visual angle for analysis. Separation thresholds varied significantly with wavelength with short-wave light (420 nm) yielding poorer resolution compared to long-wave light (660 nm). Iris pigmentation (color, lightness, and a combination of color + lightness) also influenced performance with lighter irides associated with higher thresholds, and the largest group differences observed at short wavelengths. Two-point resolution shows systematic wavelength dependence under equal-energy conditions, with performance degraded in the short-wave range. These effects likely reflect the combined influence of chromatic aberration, optical scatter, and photoreceptor sampling, rather than scatter alone. Consideration of both optical and neural mechanisms is essential when interpreting wavelength-dependent changes in spatial vision.