Wenjing Chen

Prof. Wenjing Chen


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
WCWenjing Chen
Wenjing Chen
PZPeirong Zheng
Peirong Zheng
YBYuxiang Bu
Yuxiang Bu
YXYuanning Xu
Yuanning Xu
DLDakun Lai
Dakun Lai
Early diagnosis of paroxysmal atrial fibrillation (PAF) could prompt patients to receive timely interventions in clinical practice. Various PAF onset prediction algorithms might benefit from accurate heart rate variability (HRV) analysis and machine learning classification but are challenged by real-time monitoring scenarios. The aim of this study is to present an end-to-end deep learning-based PAFNet model that integrates a sliding window technique on raw R-R intervals of electrocardiogram (ECG) segments to achieve a real-time prediction of PAF onset. This integration enables the deep convolutional neural network (CNN) to be customized as a light-weight architecture that accommodates the size of sliding windows simply by altering the input layer, and specifically its effectiveness in making a new prediction with each new heartbeat. Catering to the potential influence of input sizes, three CNN models were trained using 50, 100, and 200 R-R intervals, respectively. For each model, the performance of the automated algorithms was evaluated for PAF prediction using a ten-fold cross-validation. As a results, a total of 56,381 PAFN-type and 56,900 N-type R-R interval segments were collected from publicly accessible ECG databases, and a promising prediction performance of the automated algorithm with 100 R-R intervals was achieved, with a sensitivity of 97.12%, a specificity of 97.77%, and an accuracy of 97.45%, respectively. Importantly, the automated algorithm with a sliding window step of 1 could process one sample in only 23.1 milliseconds and identify the onset of PAF at least 45 min in advance. The present results suggest that the sliding window technique on raw R-R interval sequences, along with deep learning-based algorithms, may offer the possibility of providing an accurate, real-time, end-to-end clinical tool for mass monitoring of PAF.

1 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CRChamod Rathnayake
Chamod Rathnayake
WCWenjing Chen
Wenjing Chen
SJSahan Jayawickrama
Sahan Jayawickrama
Dakun LaiDakun Lai
Dakun Lai
Wearable technology has become popular today not only for clinical uses but also among the general public for everyday activities such as fitness tracking and activity recognition. It’s no secret that wearable devices need to be more comfortable and that there is increasing attention to their reliability and accuracy. Therefore, researchers are making various attempts to improve these specifications. Recent research has employed multimodal fusion, rather than relying on results from a single source, such as electrocardiography (ECG) or photoplethysmography (PPG), because it enables a more comprehensive understanding of physical conditions. There are very few extensive reviews of ECG and PPG wearable multimodal fusion application systems, and they are limited to a single practical use. However, this review fills that gap and provides a comprehensive overview of recent wearable physiological monitoring technologies based on ECG and PPG, along with their modern multimodal fusion applications in the medical field. These include cuffless blood pressure estimation, stress monitoring, heart rate and heart rate variability monitoring. This presents the theoretical background, including the characteristics of ECG and PPG signals, recently developed wearable monitoring techniques for ECG and PPG, and the advantages and disadvantages of multimodal fusion. It also provides a comprehensive and comparative analysis of recent studies employing modern multimodal fusion approaches in the aforementioned medical field, as well as a discussion of the limitations and challenges of ECG-PPG wearable multimodal fusion systems reported in the literature. Therefore, this review will enable researchers to gain a complete and comprehensive understanding of the development of wearable multimodal fusion applications based on ECG and PPG.

15 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
WCWenjing Chen
Wenjing Chen
PZPeirong Zheng
Peirong Zheng
YBYuxiang Bu
Yuxiang Bu
YXYuanning Xu
Yuanning Xu
DLDakun Lai
Dakun Lai
Early diagnosis of paroxysmal atrial fibrillation (PAF) could suggest patients to receive timely interventions in clinical practice. Various PAF onset prediction algorithms might benefit from accurate heart rate variability (HRV) analysis and machine learning classification but to be challenged in real-time monitoring scenarios. The aim of this study is to present an end-to-end deep learning based PAFNet model that integrates a sliding window technique on raw R-R interval of electrocardiogram (ECG) segments to achieve a real-time prediction of PAF onsets. This integration enable the deep convolutional neural network (CNN) to be customized as a light-weight architecture that accommodates the size of sliding windows simply by altering the input layer, specifically its effectiveness in making a new prediction with each new heartbeat. Catering to potential influence of input sizes, three CNN models were trained using 50, 100, and 200 R-R intervals, respectively. For each model, the performance of automated algorithms was evaluated for PAF prediction using a ten-fold cross-validation. As a results, a total of 56,381 PAFN-type and 56,900 N-type R-R interval segments was collected from publicly accessible ECG databases, and a promising prediction performance of the automated algorithm with a 100 R-R intervals was achieved in terms of the sensitivity of 97.12%, the specificity of 97.77%, and the accuracy of 97.45%, respectively. Importantly, the automated algorithm with a sliding windows step of 1 could process one sample in only 23.1 milliseconds and identify the onset of PAF at least 45 minutes in advance. The present results suggest that the sliding window technique on raw R-R interval sequences along by deep learning based algorithms may offers the possibility of providing an accurate, real-time, and end-to-end clinical tool for mass monitoring of PAF.