Liqiang Ren

Dr. Liqiang Ren

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2024 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
GTGiuseppe V. Toia
Giuseppe V. Toia
AMAchille Mileto
Achille Mileto
ABAmir A. Borhani
Amir A. Borhani
GCGuang-Hong Chen
Guang-Hong Chen
LRLiqiang Ren
Liqiang Ren
AMand Daniele Marin
and Daniele Marin

27 May 2025 in British Journal of Radiology
Verified
Journal Article
Closed access
LRLiqiang Ren
Liqiang Ren
XDXinhui Duan
Xinhui Duan
RARichard Ahn
Richard Ahn
FKFernando Kay
Fernando Kay
LDLaleh Daftaribesheli
Laleh Daftaribesheli
LALakshmi Ananthakrishnan
Lakshmi Ananthakrishnan
Photon-counting detector CT (PCD-CT) represents a transformative advancement in CT technology, overcoming limitations of conventional energy-integrating detector (EID) based systems. It uses semiconductor materials such as cadmium telluride, cadmium zinc telluride, and silicon to directly count X-ray photons while resolving their energy levels. This energy-resolving capability ensures equal weighting of low- and high-energy photons, eliminates electronic noise, and enables material-specific imaging. The absence of physical septa in the detector—used in EIDs to prevent light photon cross-talk—results in smaller effective detector pixels in PCD-CT, enhancing detection efficiency and spatial resolution. These innovations collectively enhance diagnostic accuracy while enabling significant radiation dose reduction. This article provides a comprehensive overview of PCD-CT technology, comparing it with EID-based systems. It highlights key advantages such as superior spatial and contrast resolution, spectral imaging, and noise reduction. Additionally, the review discusses PCD-CT’s radiation dose reduction across cardiovascular, thoracic, abdominal, musculoskeletal, neuroimaging, and paediatric applications. Despite its promise, PCD-CT faces challenges, including non-ideal detector performance, increased electronic complexity, and calibration requirements to maintain accuracy. Addressing these issues will be crucial for widespread clinical adoption. As research progresses and technology improves, PCD-CT is expected to reshape clinical practice by integrating high diagnostic accuracy with improved radiation efficiency.

1 February 2025 in RadioGraphics
Verified
Journal Article
Closed access
FSFides Regina Schwartz
Fides Regina Schwartz
BDBari Dane
Bari Dane
SSShan Su
Shan Su
KKKhanin Khanungwanitkul
Khanin Khanungwanitkul
LRLiqiang Ren
Liqiang Ren
LALakshmi Ananthakrishnan
Lakshmi Ananthakrishnan
Understanding the unique features of photon-counting CT and being familiar with terminology and setup processes are essential to effectively implement this modality in clinical practice.

1 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AAAfrouz Ataei
Afrouz Ataei
VVVasantha Vasan
Vasantha Vasan
TSTodd C. Soesbe
Todd C. Soesbe
CBCecelia C. Brewington
Cecelia C. Brewington
ZZZhongxing Zhou
Zhongxing Zhou
LRLiqiang Ren
Liqiang Ren
Simultaneous dual-contrast imaging of iodine and bismuth has shown promise in prior phantom and animal studies utilizing spectral CT. However, it is noted that in previous studies, Pepto-Bismol has frequently been employed as the source of bismuth, exceeding the recommended levels for human subjects. This investigation sought to assess the feasibility of visually differentiating and precisely quantifying low-concentration bismuth using clinical dual-source photon-counting CT (PCCT) in a scenario involving both iodinated and bismuth-based contrast materials. Four bismuth samples (0.6, 1.3, 2.5, and 5.1 mg/mL) were prepared using Pepto-Bismol, alongside three iodine rods (1, 2, and 5 mg/mL), inserted into multi-energy CT phantoms with three different sizes, and scanned on a PCCT system at three tube potentials (120, 140, and Sn140 kV). A generic image-based three-material decomposition method generated iodine and bismuth maps, with mean mass concentrations and noise levels measured. The root-mean-square errors for iodine and bismuth determined the optimal tube potential. The tube potential of 140 kV demonstrated optimal quantification performance when both iodine and bismuth were considered. Distinct differentiation of iodine rods with all three concentrations and bismuth samples with mass concentrations ≥ 1.3 mg/mL was observed across all phantom sizes at the optimal kV setting.

20 November 2025 in European Journal of Radiology
Verified
Journal Article
Closed access
LRLiqiang Ren
Liqiang Ren
RARichard W Ahn
Richard W Ahn
VVVasantha Vasan
Vasantha Vasan
XDXinhui Duan
Xinhui Duan
DIDarren Imphean
Darren Imphean
LALakshmi Ananthakrishnan
Lakshmi Ananthakrishnan

30 May 2024 in Radiology Case Reports
Verified
Journal Article
Open access
TSTodd C. Soesbe
Todd C. Soesbe
RARichard W. Ahn
Richard W. Ahn
LRLiqiang Ren
Liqiang Ren
SSStephen Seiler
Stephen Seiler
AAAndres Abadia
Andres Abadia
MLMatthew A. Lewis
Matthew A. Lewis
We present a case of an 81-year-old woman who presented to the emergency department with bleeding from a right breast wound. The patient had prior imaging suggestive of bilateral silicone implant rupture and a history of low tolerance for MRI scans. Ultrasound imaging in the emergency setting showed findings in the right breast suggestive of a fistula with free silicone and hematoma. A subsequent photon-counting CT scan with custom silicone-specific segmentation allowed differentiation of silicone from hematoma, provided anatomic assessment and location of the fistula, and revealed bilateral silicone-induced lymphadenopathy.