Marcin Januszewski

Dr. Marcin Januszewski


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
DRDesire Dauphin Rasolomampionona
Desire Dauphin Rasolomampionona
MPMichał Połecki
Michał Połecki
KZKrzysztof Zagrajek
Krzysztof Zagrajek
WWWiktor Wróblewski
Wiktor Wróblewski
MJMarcin Januszewski
Marcin Januszewski
Load frequency control (LFC) is one of the most important tools in power system control. LFC is an auxiliary service related to the short-term balance of energy and frequency of power systems. As such, it allows the acquisition of a central role in enabling electricity exchanges and providing better conditions. The classification of LFC can be carried out from different angles: we can enumerate, among others, the type of control used. The following types of control are presented in this review: classical, optimal, and robust control. More advanced controls can also be used for classification: fuzzy logic control, ANN control, genetic algorithms, PSO control, etc. The influence of renewables and power control tools like FACTS is also considered as a category to be analyzed. The last classifications are related to two important subjects—the influence of DC links on LFC efficiency and the dangers of cyberattacks on the LFC.

9 December 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
SRSylwester Robak
Sylwester Robak
JMJan Machowski
Jan Machowski
MSMateusz Skwarski
Mateusz Skwarski
MJMarcin Januszewski
Marcin Januszewski
This paper proposes a new event-based logic of the breaker failure protection to improve power system transient stability by shortening the total clearing time of extreme contingencies involving circuit breaker failures. Stability improvement is achieved by using dual-timer protection with shorter safety margin for multi-phase faults close to the power plant and longer safety margin for remote multi-phase faults and single-phase faults. The use of the output signal obtained for a short safety margin depends on how the substation is configured. In the breaker-and-a-half configuration, this output signal is used to speed up the opening of all adjacent circuit breakers. In substations with the dual (or triple) busbar configuration the output signal obtained with a short safety margin is used to speed up the busbar splitting. A case study was performed for a real large-scale power system. Simulation results confirmed the advantages of the proposed logic. Breaker failure protection with the proposed logic has been implemented in a substation of a large power plant.

3 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
WWWiktor Wróblewski
Wiktor Wróblewski
RKRyszard Kowalik
Ryszard Kowalik
MJMarcin Januszewski
Marcin Januszewski
KKKarol Kurek
Karol Kurek
This paper introduces a Fuzzy Logic Controller designed for an on-load tap changer within medium voltage distribution systems with bulk penetration of Distributed Energy Resources. As the on-load tap changer remains one of the most essential forms of voltage regulation in medium voltage distribution networks, improving its operation is a cost-effective response to the emerging voltage violations caused by intermittent generation during the early stages of the energy system transformation. Software-in-the-loop simulations were conducted to validate the effectiveness of the proposed algorithm compared to the conventional methods. A modified CIGRE Medium Voltage Distribution Network Benchmark in European Configuration was modelled while the controller code developed in Python 3.12 was running on a PC, both coupled in a real-time closed-loop environment. The analyses showed that the proposed algorithm managed to reduce overvoltage from 7.02% to 4.85% in the benchmark network, thus demonstrating that the algorithm is efficient and ready for on-field implementation.

16 May 2022 in Symmetry
Verified
Journal Article
Open access
PDF file
AŁArtur Łukaszewski
Artur Łukaszewski
ŁNŁukasz Nogal
Łukasz Nogal
MJMarcin Januszewski
Marcin Januszewski
The recent trends in the development of power systems are focused on the Self-Healing Grid technology fusing renewable energy sources. In the event of a failure of the power system, automated distribution grids should continue to supply energy to consumers. Unfortunately, there are currently a limited number of algorithms for rebuilding a power system with renewable energy sources. This problem is possible to solve by implementing restoration algorithms based on graph theory. This article presents the new modification of Prim’s algorithm, which has been adapted to operate on a power grid containing several power sources, including renewable energy sources. This solution is unique because Prim’s algorithm is ultimately dedicated to single-source graph topologies, while the proposed solution is adapted to multi-source topologies. In the algorithm, the power system is modeled by the adjacency matrices. The adjacency matrixes for the considered undirected graphs are symmetric. The novel logic is based on the original method of determining weights depending on active power, reactive power and active power losses. The developed solution was verified by performing a simulation on a test model of the distribution grid powered by a renewable energy source. The control logic concept was compared with the reference algorithms, which were chosen from the ideas representing available approaches based on graph theory present in the scientific publications. The conducted research confirmed the effectiveness and validity of the novel restoration strategy. The presented algorithm may be applied as a restoration logic dedicated to power distribution systems.

2 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
RJRadoslaw Jez
Radoslaw Jez
MLMichal Lazarczyk
Michal Lazarczyk
JEJakub Ejma-Multanski
Jakub Ejma-Multanski
RKRyszard Kowalik
Ryszard Kowalik
MJMarcin Januszewski
Marcin Januszewski
MSMarcin Szewczyk
Marcin Szewczyk
The deployment of Electrically Trace Heated Pipe-in-Pipe (ETH-PiP) brings the challenges of reliable protection selection and setting. This paper presents a study of relays and protection function optimization for ETH-PiP systems. The study is based on the developed simulation model of a typical ETH-PiP system. The paper presents simulation studies of physical phenomena occurring during electrical disturbances in the ETH-PiP system and offers detailed analyses applicable to system protection, including detection of disturbances, location, and elimination.

1 January 2020 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
MJMarcin Januszewski
Marcin Januszewski
RKRyszard Kowalik
Ryszard Kowalik
KKKarol Kurek
Karol Kurek
EBEmil Bartosiewicz
Emil Bartosiewicz
ASAdam Smolarczyk
Adam Smolarczyk
DRDesire Dauphin Rasolomampionona
Desire Dauphin Rasolomampionona
This article describes the comparison of test results of distance protection functions (ANSI 21) implemented in protective relays of various manufacturers dedicated to HV and EHV lines protection. A special emphasis has been placed on determining the operating times of distance protection functions based on quadrilateral and circular characteristics.The research was conducted using classical methods based on the use of software provided by the manufacturer of microprocessor-based tester and the use of simulation programs.