BACKGROUND AND PURPOSE: Intraplaque hemorrhage within intracranial atherosclerotic plaques identified by high-resolution MR imaging has been studied as a potential marker of stroke risk. However, previous studies only examined intracranial arteries with high-grade stenosis (degree of stenosis, >50%). This study aimed to ascertain the clinical relevance of intraplaque hemorrhage in patients with low- and high-grade stenotic basilar artery plaques. MATERIALS AND METHODS: Patients with basilar artery stenosis (n = 126; mean age, 62 ± 10 years; 66 symptomatic and 60 asymptomatic) underwent high-resolution MR imaging. The relationship between imaging findings (intraplaque hemorrhage, contrast enhancement, degree of stenosis, minimal lumen area, and plaque burden) and symptoms was analyzed. RESULTS: Intraplaque hemorrhage was identified in 22 patients (17.5%), including 21 (31.8%) symptomatic patients and 1 (1.7%) asymptomatic patient. Multivariate analysis showed that intraplaque hemorrhage was the strongest independent marker of symptomatic status (odds ratio, 27.5; 95% CI, 3.4–221.5; P = .002). Contrast enhancement was also independently associated with symptomatic status (odds ratio, 9.9; 95% CI, 1.5–23.6; P = .016). Stenosis, minimal lumen area, and plaque burden were not correlated with symptoms (P > .05). Intraplaque hemorrhage was present in both low- and high-grade stenotic basilar arteries (11.3% versus 16.3%, P = .63). Diagnostic performance values of intraplaque hemorrhage for patients with acute/subacute symptomatic stroke were the following: specificity, 98.3%; sensitivity, 31.8%; positive predictive value, 95.5%; and negative predictive value, 56.7%. CONCLUSIONS: Intraplaque hemorrhage is present in both low- and high-grade stenotic basilar artery plaques and is independently associated with symptomatic stroke status. Intraplaque hemorrhage may identify high-risk plaque and provide new insight into the management of patient with stroke without significant stenosis.
8 October 2020 in Journal of Magnetic Resonance Imaging
To explore the effect of b-value distributions on the repeatability and diagnostic performance of the ADC value in rectal cancer patients using multiple b-values and mono-exponential model diffusion-weighted imaging (DWI). Thirty-two preoperative rectal cancer patients, without receiving neoadjuvant therapy, were scanned on a 3 Tesla magnetic resonance imaging scanner using DWI with 10 b-values ranging from 0 to 2000 s/mm2. The apparent diffusion coefficient (ADC) value was calculated using a mono-exponential model and 31 b-value combinations consisting of 2 to 10 b-values were explored. Regions of interest with the maximum cross-sectional tumour size were outlined on the ADC map by two independent observers. Intraclass correlation coefficients (ICC), coefficient of variation (CV), and Bland-Altman plots between the two observers were calculated and evaluated to determine repeatability. Areas under receiver operating characteristic curves (AUCs) were evaluated for rectal cancer characterization. Correlations between the mean ADC values and T stage were assessed using the Spearman correlation coefficient (ρ). α (= ICC + AUC + |ρ|- CV - |bias|) was defined and used to assess the optimal b-value distribution. Postoperative pathology tests revealed 4 patients with T1, 10 patients with T2, and 18 patients with T3 stages. There were no significant difference in age and sex between the two groups (T1–2 vs. T3). Excellent reproducibility was observed for ADC values between two observers with ICC and CV values ranging from 0.920 to 0.998, and 1.475 to 5.568%, respectively. The mean percent difference and ρ between the paired measurements was ranged from − 2.7 to 1.2% and from − 0.759 to − 0.407, respectively. The b-value combinations with the top three α values were b(0, 1000 s/mm2), b(500, 1500, 2000 s/mm2) and b(100, 1000, 1500 s/mm2) for α = 2.581, 2.571 and 2.569, respectively. The number of b-values and their distributions influenced the repeatability of the ADC values and their diagnostic performance. The optimal b-value combination was 0 and 1000 s/mm2 for DWI examination of rectal cancer patients.
Background: To explore the usefulness of analyzing histograms and textures of apparent diffusion coefficient (ADC) maps and T2-weighted (T2W) images to differentiate prostatic cancer (PCa) from benign prostatic hyperplasia (BPH) using histopathology as the reference.Methods: Ninety patients with PCa and 112 patients with BPH were included in this retrospective study. Differences in whole-lesion histograms and texture parameters of ADC maps and T2W images between PCa and BPH patients were evaluated using the independent samples t-test. The diagnostic performance of ADC maps and T2W images in being able to differentiate PCa from BPH was assessed using receiver operating characteristic (ROC) curves.Results : The mean, median, 5th, and 95thpercentiles of ADC values in images from PCa patients were significantly lower than those from BPH patients (p < 0.05). Significant differences were observed in the means, standard deviations, medians, kurtosis, skewness, and 5thpercentile values of T2W image between PCa and BPH patients (p < 0.05). The ADC5thshowed the largest AUC (0.906) with a sensitivity of 83.3 % and specificity of 89.3 %. The diagnostic performance of the T2W image histogram and texture analysis was moderate and had the largest AUC of 0.634 for T2WKurtosiswith a sensitivity and specificity of 48.9% and 79.5 %, respectively. The diagnostic performance of the combined ADC5th& T2WKurtosisparameters was also similar to that of the ADC5th& ADCDiff−Variance.Conclusions: Histogram and texture parameters derived from the ADC maps and T2W images for entire prostatic lesions could be used as imaging biomarkers to differentiate PCa and BPH biologic characteristics, however, histogram parameters outperformed texture parameters in the diagnostic performance.
To evaluate whether readout-segment echo-planar imaging (RS-EPI) can provide better image quality in assessing bladder cancer than single-shot echo-planar imaging (SS-EPI) and to compare quantitative imaging parameters derived from both techniques. Seventy patients with bladder lesions were enrolled and underwent diffusion-weighted imaging on a 3 Tesla magnetic resonance scanner using axial RS-EPI and SS-EPI techniques. Two observers independently assessed the susceptibility, detectability, motion artefacts and blurring of the images using qualitative scores. The signal-to-noise ratio (SNR), signal intensity ratio (SIR), contrast-to-noise ratio (CNR) and ADC values of the bladder lesions were measured and compared between the two techniques and between two observers. Qualitative and quantitative comparisons of image quality were performed using the Wilcoxon signed-rank test and paired t-test. In addition, the agreement of the ADC measurements was evaluated using ICC values and Bland-Altman plots. Sixty-eight patients were included in the final analysis. The scores of image susceptibility, detectability and blurring for RS-EPI were significantly higher than those for SS-EPI (all p < 0.05), while the motion artefact was not. There were significant differences between RS-EPI and SS-EPI in the CNR and SIR values (all p < 0.05) but not in the SNR or ADC values (all p > 0.05). The ICC values and Bland-Altman plots also showed excellent agreement between the measured ADC values of the bladder lesions. The RS-EPI technique provides significantly better image quality in patients with bladder cancer than the SS-EPI technique, without a significant difference in the ADC value.