Differentiation of pancreatic carcinoma and mass-forming focal pancreatitis: qualitative and quantitative assessment by dynamic contrast-enhanced MRI combined with diffusion-weighted imaging
To investigate the influence of region of interest (ROI) size on tumor apparent diffusion coefficient (ADC) measurements in pancreatic cancer. The study population consisted of 64 patients with pathologically proved pancreatic ductal adenocarcinomas (PDACs), who underwent preoperative magnetic resonance imaging (MRI) examinations including diffusion-weighted imaging (DWI). The tumor ADCs were measured by two independent readers using six round ROIs with sizes ranging from 20 to 214 mm2 (9 to 97 pixels) in both the six separate measurements. The intra- and inter-observer variabilities were analyzed by using the coefficient of variance (CV), the interclass correlation coefficient (ICC) and Bland-Altman analysis. The mean ADCs measured with the 6 different-sized ROIs were compared using one-way repeated analysis of variance. The sample sizes were calculated by using 80% power and a 5% significance level to detect 10 to 25% changes in ADC measurements. The largest ROI (ROI214) yielded the best intra-observer repeatability (CV, 6.3%; ICC, 0.93) and inter-observer reproducibility (CV, 10.1%; ICC, 0.84). The mean differences in ADC measurements ± limits of agreement between the two readers were (0.06 ± 0.47) × 10−3 mm2 for ROI20, (0.08 ± 0.46) × 10−3 mm2 for ROI46, (0.05 ± 0.37) × 10−3 mm2 for ROI82, (0.07 ± 0.42) × 10−3 mm2 for ROI115, (0.05 ± 0.43) × 10−3 mm2 for ROI152 and (−0.02 ± 0.29) × 10−3 mm2 for ROI214. ROI size had a considerable influence on the ADC measurements of PDACs.
To evaluate whether readout-segment echo-planar imaging (RS-EPI) can provide better image quality in assessing bladder cancer than single-shot echo-planar imaging (SS-EPI) and to compare quantitative imaging parameters derived from both techniques. Seventy patients with bladder lesions were enrolled and underwent diffusion-weighted imaging on a 3 Tesla magnetic resonance scanner using axial RS-EPI and SS-EPI techniques. Two observers independently assessed the susceptibility, detectability, motion artefacts and blurring of the images using qualitative scores. The signal-to-noise ratio (SNR), signal intensity ratio (SIR), contrast-to-noise ratio (CNR) and ADC values of the bladder lesions were measured and compared between the two techniques and between two observers. Qualitative and quantitative comparisons of image quality were performed using the Wilcoxon signed-rank test and paired t-test. In addition, the agreement of the ADC measurements was evaluated using ICC values and Bland-Altman plots. Sixty-eight patients were included in the final analysis. The scores of image susceptibility, detectability and blurring for RS-EPI were significantly higher than those for SS-EPI (all p < 0.05), while the motion artefact was not. There were significant differences between RS-EPI and SS-EPI in the CNR and SIR values (all p < 0.05) but not in the SNR or ADC values (all p > 0.05). The ICC values and Bland-Altman plots also showed excellent agreement between the measured ADC values of the bladder lesions. The RS-EPI technique provides significantly better image quality in patients with bladder cancer than the SS-EPI technique, without a significant difference in the ADC value.
This study aims to evaluate the utility of calculated computed tomography (CT) attenuation value ratio (AVR) and enhancement pattern in distinguishing pancreatic solid serous cystadenomas (SCAs) from nonfunctional pancreatic neuroendocrine tumors (NF-pNETs). A total of 142 consecutive patients with 22 solid SCAs and 120 NF-pNETs confirmed by pathology were included in this retrospective study. All patients underwent preoperative contrast-enhanced CT and were categorized into 2 groups, solid SCA and NF-pNET groups. Patients with NF-pNETs were matched to patients with solid SCAs via propensity scores. AVR was measured and defined as: attenuation value of tumor/attenuation value of normal pancreas. AVR and enhancement pattern performance were assessed according to the discriminative abilities of patients. After matching, 29 patients were allocated to the NF-pNET group. Before matching, sex, age, and the peak enhanced value phase were significantly different between solid SCA and NF-pNET patients (P < .05). After matching, no significant difference was observed between both groups (P > .05). Solid SCAs AVRs were significantly smaller than NF-pNETs AVRs in all unenhanced, arterial, portal venous, and delayed phases (P < .05). Solid SCAs showed significantly more wash-in and wash-out enhancement patterns than NF-pNETs (P < .05). For unenhanced, arterial, portal venous, and delayed phases, and enhancement pattern, the area under the curve (AUC) values were 0.96, 0.72, 0.80, 0.85, and 0.86, respectively. Low AVR on unenhanced CT and wash-in and wash-out enhancement patterns were useful for differentiating solid SCAs from NF-pNETs and may be useful for clinical decisions, a clearer opinion will be formed with further studies to be conducted with larger patient numbers.