Zhongyun Yuan

Prof. Dr. Zhongyun Yuan

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
XLXuebiao Li
Xuebiao Li
JLJianing Li
Jianing Li
TWTao Wang
Tao Wang
Saeed Ahmed KhanSaeed Ahmed Khan
Saeed Ahmed Khan
ZYZhongyun Yuan
Zhongyun Yuan
HZHulin Zhang
Hulin Zhang

12 September 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
JWJie Wang
Jie Wang
SQShuo Qian
Shuo Qian
JYJunbin Yu
Junbin Yu
QZQiang Zhang
Qiang Zhang
ZYZhongyun Yuan
Zhongyun Yuan
LSLining Sun
Lining Sun
Flexible electronics devices with tactile perception can sense the mechanical property data of the environment and the human body, and they present a huge potential in the human health system. In particular, the introduction of ultra-flexible and self-powered characteristics to tactile sensors can effectively reduce the problems caused by rigid batteries. Herein, we report a triboelectric nanogenerator (TENG), mainly consisting of an ultra-flexible polydimethylsiloxane (PDMS) film with micro-pyramid-structure and sputtered aluminum electrodes, which achieves highly conformal contact with skin and the self-powered detection of human body motions. The flexible polyethylene terephthalate (PET) film was selected as spacer layer, which made the sensor work in the contact-separation mode and endowed the perfect coupling of triboelectrification and electrostatic induction. Moreover, the controllable and uniform micro-structure PDMS film was fabricated by using the micro-electro-mechanical system (MEMS) manufacturing process, bringing a good sensitivity and high output performance to the device. The developed TENG can directly convert mechanical energy into electric energy and light up 110 green Light-Emitting Diodes (LEDs). Furthermore, the TENG-based sensor displays good sensitivity (2.54 V/kPa), excellent linearity (R2 = 0.99522) and good stability (over 30,000 cycles). By virtue of the compact size, great electrical properties, and great mechanical properties, the developed sensor can be conformally attached to human skin to monitor joint movements, presenting a promising application in wearable tactile devices. We believe that the ultra-flexible and self-powered tactile TENG-based sensor could have tremendous application in wearable electrons.

1 September 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SSShengbo Sang
Shengbo Sang
YLYuchao Li
Yuchao Li
XGXing Guo
Xing Guo
BZBo Zhang
Bo Zhang
XXXianwei Xue
Xianwei Xue
ZYZhongyun Yuan
Zhongyun Yuan

22 October 2021 in ACS Sensors
Verified
Journal Article
Closed access
XHXinru Huang
Xinru Huang
SSShengbo Sang
Shengbo Sang
ZYZhongyun Yuan
Zhongyun Yuan
QDQianqian Duan
Qianqian Duan
XGXing Guo
Xing Guo
CZChun Zhao
Chun Zhao

16 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
XGXing Guo
Xing Guo
RLRong Liu
Rong Liu
HLHongmei Li
Hongmei Li
JWJingzhe Wang
Jingzhe Wang
ZYZhongyun Yuan
Zhongyun Yuan
Shengbo SangShengbo Sang
Shengbo Sang
For the first time, a novel NiFe2O4/paper-based magnetoelastic (ME) biosensor was developed for rapid, sensitive, and portable detection of human serum albumin (HSA). Due to the uniquely magnetoelastic effect of NiFe2O4 nanoparticles and the excellent mechanical properties of the paper, the paper-based ME biosensor transforms the surface stress signal induced by the specific binding of HSA and antibody modified on the paper into the electromagnetic signal. The accumulated binding complex generates a compressive stress on the biosensor surface, resulting in a decrease in the biosensor’s static magnetic permeability, which correlates to the HSA concentrations. To improve the sensitivity of the biosensor, the concentration of NiFe2O4 nanofluid and the impregnated numbers of the NiFe2O4 nanofluid-impregnated papers were optimized. The experimental results demonstrated that the biosensor exhibited a linear response to HSA concentrations ranging from 10 μg∙mL−1 to 200 μg∙mL−1, with a detection limit of 0.43 μg∙mL−1, which is significantly lower than the minimal diagnosis limit of microalbuminuria. The NiFe2O4/paper-based ME biosensor is easy to fabricate, and allows the rapid, highly-sensitive, and selective detection of HSA, providing a valuable analytical device for early monitoring and clinical diagnosis of microalbuminuria and nephropathy. This study shows the successful integration of the paper-based biosensor and the ME sensing analytical method will be a highly-sensitive, easy-to-use, disposable, and portable alternative for point-of-care monitoring.

29 March 2022 in ACS Omega
Verified
Journal Article
Open access
AJAoqun Jian
Aoqun Jian
JWJunhe Wang
Junhe Wang
HLHongying Lin
Hongying Lin
SXShiqiang Xu
Shiqiang Xu
DHDan Han
Dan Han
KZKai Zhuo
Kai Zhuo
MoS2 nanochains were successfully prepared via facile electrospinning and a hydrothermal process. The morphology of MoS2 nanochains was evaluated by field emission scanning electron microscopy and high-resolution transmission electron microscopy. A slurry composed of the MoS2 nanochains was coated on a silver electrode to detect ammonia. The detection range of ammonia was between 25 and 500 ppm. MoS2 nanochains offered outstanding sensing response, repeatable reproducibility, and excellent selectivity with a detection limit of 720 ppb. The responsiveness of MoS2 nanochains to ammonia remained unchanged for 1 week.