Strontium (Sr) is an alkaline earth metal that exerts the dual effect of improving bone formation and suppressing bone resorption, resulting in increased bone apposition rates and bone mineral density. However, the mechanisms through which Sr exerts these beneficial effects on bone have yet to be fully elucidated. The present study aimed to reveal the underlying molecular mechanisms associated with Sr‑induced osteogenic differentiation. The effects of Sr on cell proliferation and osteogenic differentiation were analyzed by MTT assay, RT‑qPCR, western blot analysis, alkaline phosphatase (ALP) and Alizarin red staining assays. The extent of autophagy was determined by monodansylcadaverine (MDC) staining and western blot analysis of two markers of cellular autophagic activity, the steatosis‑associated protein, sequestosome‑1 (SQSTM1/p62), and the two isoforms of microtubule‑associated protein 1 light chain 3 (LC3), LC‑3‑I/II. The expression levels of AMP‑activated protein kinase (AMPK) and mammalian target of rapamycin (mTOR) were also detected by western blot analysis. Sr at a concentration of 3 mM exerted the most pronounced effect on osteogenic differentiation, without any apparent cell toxicity. At the same time, cellular autophagy was active during this process. Subsequently, autophagy was blocked by 3‑methyladenine, and the enhancement of osteogenic differentiation in response to Sr was abrogated. Additionally, the phosphorylation level of AMPK was significantly increased, whereas that of mTOR was significantly decreased, in the Sr‑treated group. Taken together, the findings of the present study demonstrate that Sr stimulates AMPK‑activated autophagy to induce the osteogenic differentiation of MC3T3‑E1 cells.
1 October 2021 in Journal of Immunological Methods
Background: Specific IgE (sIgE) testing has become one of the most important tools for diagnosing IgE‐mediated food allergy. Enzyme‐linked immunosorbent assay (ELISA) and dot‐enzyme‐linked immunosorbent assay (Dot‐ELISA) have been used to measure sIgE in clinical widely. Light‐initiated chemiluminescence assay (LICA) is a new method for measuring allergen‐sIgE. We aimed to establish a LICA method for quantitative detection of egg white‐sIgE and evaluate its performances.Methods: The best chemibeads coupling method in detecting egg white‐sIgE was selected, and a LICA method for quantitative detection of egg white‐sIgE was established. The precision study was performed according to Clinical and Laboratory Standards Institute (CLSI) EP5‐A2. Detection capability which contains limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) was evaluated according to National Health Commission of the People's Republic of China (NHC) WS/T 514–2017. Linear range was evaluated according to CLSI EP6‐A. All data were analyzed using SPSS software.Results: Precision contains repeatability and intermediate precision. The CV of repeatability ranged from 2.72% to 7.29%, and the CV of intermediate precision ranged from 4.93% to 8.64%. The LoB, LoD, and LoQ of the assay were 0.000 kUA/L, 0.053 kUA/L, and 0.076 kUA/L. The assay linear range was 0.076–34.125 kUA/L (r = 0.9979 ≥ 0.9900).Conclusion: This laboratory‐developed LICA method can detect egg white‐sIgE, and performance meets clinical requirements. This method shows rapid turnaround cycles and high sensitivity. It can be used as an alternative method for clinical detection of egg white‐sIgE.
Conventional microfluidic systems that rely on capillary force have a fixed structure and limited sensitivity, which cannot meet the demands of clinical applications. Herein, we propose a dual-drive microfluidic device for sensitive and flexible detection of multiple pathogenic microorganisms antigens/antibodies. The device comprises a portable microfluidic analyzer and a dual-drive microfluidic chip. Along with capillary force, a second active driving force is provided by a removable self-driving valve in the waste chamber. The interval between these two driving forces can be adjusted to control the reaction time in the microchannel, optimizing the formation of antigen-antibody complexes and enhancing sensitivity. Moreover, the material used in the self-driving valve can be changed to adjust the active force strength needed for different tests. The device offers quantitative analysis for respiratory syncytial virus antigen and SARS-CoV-2 antigen using a 35 μL sample, delivering results within 5 min. The detection limits of the system were 1.121 ng/mL and 0.447 ng/mL for respiratory syncytial virus recombinant fusion protein and SARS-CoV-2 recombinant nucleoprotein, respectively. Although the dual-drive microfluidic device has been used for immunoassay for respiratory syncytial virus and SARS-CoV-2 in this study, it can be easily adapted to other immunoassay applications by changing the critical reagents.
To establish a new method for quantitative detection of house dust mite (HDM)–sIgE based on light-initiated chemiluminescence assay (LiCA). The assay was established after optimizing the reaction conditions, and the assay performance was evaluated according to the clinical guidelines. Further, the results of LiCA were compared with those from the ELISA and ImmunoCAP methods. Coefficients of variation for repeatability ranged from 4.22% to 7.69%, and intermediate precision from 8.38% to 10.34%. The limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were 0.066 kUA/L, 0.165 kUA/L, and 0.171 kUA/L, respectively. The coefficient of correlation (r) between the results of LiCA and ELISA was 0.9263, and the r between the results of LiCA and ImmunoCAP was 0.8870. A HDM-sIgE quantitation assay based on LiCA was established, which could be used as a new reliable analytical tool for the determination of HDM-sIgE.