Anthoula Menti

Dr. Anthoula Menti

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Energy Reports
Verified
Journal Article
Open access
AMAnthoula Menti
Anthoula Menti
DBDimitrios Barkas
Dimitrios Barkas
SKStavros Kaminaris
Stavros Kaminaris
Constantinos S. PsomopoulosConstantinos S. Psomopoulos
Constantinos S. Psomopoulos

25 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
AMAnthoula Menti
Anthoula Menti
PPPavlos Pachos
Pavlos Pachos
Constantinos S. PsomopoulosConstantinos S. Psomopoulos
Constantinos S. Psomopoulos
Grid-connected photovoltaic (PV) systems inject nonsinusoidal currents into the grid at the point of their connection. The technology of the inverter utilized for the conversion of DC power into AC is directly associated with distortion characteristics. Even though pulse-width-modulated (PWM) converters generate considerably lower harmonic distortion than their predecessors, they are responsible for the emergence of a new power quality issue in distribution grids known as supraharmonics, which can cause problems such as overheating and malfunctions of equipment. PV systems are known sources of supraharmonics, but their impact has not yet been thoroughly researched. Due to the multitude of parameters affecting their performance, a more rigorous treatment is required compared to more common nonlinear devices. In this paper, emissions from a three-phase grid-connected PV system are examined by means of a dedicated simulation tool taking into account the specifics of inverter switching action without overly increasing computational cost. The impact of environmental parameters as well as factors affecting the switch control of the converter is investigated. The dependence of the supraharmonic emission of the PV system on the converter characteristics rather than environmental conditions is demonstrated. Furthermore, simulation studies on a network comprising the PV system and an additional supraharmonic-emitting system in simultaneous operation are conducted. Their combined effect on the distortion at the connection point of the network to the grid is assessed by means of a power flow-based approach, capable of quantifying interactions within this network. From the viewpoint of the grid, an increase of supraharmonic-related disturbance at low irradiance conditions is revealed.

20 February 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
NSNikolaos Skarkos
Nikolaos Skarkos
AMAnthoula Menti
Anthoula Menti
Konstantinos George KalkanisKonstantinos George Kalkanis
Konstantinos George Kalkanis
ICIOANNIS CHRONIS
IOANNIS CHRONIS
Constantinos S. PsomopoulosConstantinos S. Psomopoulos
Constantinos S. Psomopoulos
Photovoltaic (PV) technologies are developing rapidly as a result of their ability to reduce energy consumption from conventional sources as well as the growth of global energy expenditures. Nevertheless, several impact categories during the PV panel life cycle occur and some principal sectors are affected. These impact categories are assessed by applying life cycle analysis (LCA) techniques through various software programs, databases and methods. Such analyses of energy technologies are crucial, as they can reveal the occurrence of hazardous emissions at distinct life cycle stages. In the present paper, a PV panel impact assessment through life cycle analysis is carried out. More precisely, a combination of PV technologies—monocrystalline, multicrystalline, copper indium gallium selenide (CIGS), amorphous, and ribbon—is studied. The impact categories of ozone depletion, human toxicity, particulate matter, ionising radiation, photochemical ozone formation, acidification, eutrophication, and ecotoxicity, as well as the sectors of human health, ecosystem quality, and environment, are assessed using the openLCA software, the ecoinvent database, the eco-indicator 99, IMPACT 2002+, ReCiPe, and TRACI methods.

15 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
VRVasiliki Rokani
Vasiliki Rokani
SKStavros D. Kaminaris
Stavros D. Kaminaris
Constantinos S. PsomopoulosConstantinos S. Psomopoulos
Constantinos S. Psomopoulos
PKPetros Dionisios Karaisas
Petros Dionisios Karaisas
AMAnthoula Menti
Anthoula Menti
Power transformers are critical assets in complex power grid systems, yet On-Load Tap Changers (OLTCs) account for over 30% of documented outages. This study introduces a Health Index (HI) model for OLTCs that employs a Fuzzy-Logic system to enhance condition-based maintenance (CBM) techniques. This research presents a component-wise, Fuzzy-Logic–based HI evaluation using the Scoring Methodology. The OLTC component is subdivided into six smaller components or contributors. Every contributor is a crucial subsystem whose efficacy is vital to the transformer’s overall reliability. Each contributor is divided into three sub-contributors/values and assessed using a three-tier classification scale (A, B, or C). These values could indicate condition measurements, operational observations, and diagnostic data. Each value is evaluated against reference ranges or boundary values derived from a synthesis of international standards, statistical population studies, and expert knowledge. To verify the precision of the proposed methodology, several defective OLTC cases were evaluated under diverse operational settings. This Fuzzy-Logic (FL) approach seeks to deliver a more accurate and interpretable assessment of OLTC condition than traditional crisp-value methods by integrating expert knowledge, diagnostic metrics, and standards within a structured Fuzzy-Inference framework. The implicit FL model is inherently more attuned to early indicators of deterioration and hidden risk factors that may be underestimated in conventional expert evaluations. Implementation of this intelligent monitoring approach enables early fault diagnosis, extends the transformer’s operational life, and reduces the risk of catastrophic failures and unplanned outages in the electrical power network.