A previously proposed nonlinear inverse reconstruction for autocalibrated parallel imaging simultaneously estimates coil sensitivities and image content. This work exploits this property for real‐time MRI, where coil sensitivities need to be dynamically adapted to the conditions generated by moving objects. The development comprises (i) an extension of the nonlinear inverse algorithm to non‐Cartesian k‐space encodings, (ii) its implementation on a graphical processing unit to reduce reconstruction times, and (iii) the use of a convolution‐based iteration, which considerably simplifies the graphical processing unit implementation compared to a gridding technique. The method is validated for real‐time MRI of the human heart at 3 T using radio frequency‐spoiled radial FLASH (pulse repetition time/echo time = 2.0/1.3 ms, flip angle 8°). The results demonstrate artifact‐free reconstructions from only 65–85 spokes, with 256 oversampled data points. Acquisition times of 130–170 ms resulted in 29–38 frames per second for sliding window reconstructions (factor 5). While offline reconstructions required 1–2 sec, real‐time applications with modified parameters and slightly lower image quality were achieved within 90 ms per graphical processing unit. Magn Reson Med 63:1456–1462, 2010.
Dynamic MRI studies of the upper airway during speaking, singing or swallowing are complicated by the need for high temporal resolution and the presence of air‐tissue interfaces that may give rise to image artifacts such as signal void and geometric distortions. This work exploits a recently developed real‐time MRI technique to address these challenges for monitoring speech production at 3 T. The method combines a short‐echo time radial FLASH MRI sequence (pulse repetition time/echo time = 2.22/1.44 ms; flip angle 5°) with pronounced undersampling (15 radial spokes per image) and image reconstruction by regularized nonlinear inversion. The resulting serial images at 1.5 mm in‐plane resolution and 33.3 ms acquisition time are free of motion or susceptibility artifacts. This application focuses on a dynamic visualization of the main articulators during natural speech production (Standard Modern German). Respective real‐time MRI movies at 30 frames per second clearly demonstrate the spatiotemporal coordination of lips, tongue, velum, and larynx for generating vowels, consonants, and coarticulations. The quantitative results for individual phonetic events are in agreement with previous non‐MRI findings. Magn Reson Med, 2013.
1 October 2010 in Journal of Cardiovascular Magnetic Resonance
Functional assessments of the heart by dynamic cardiovascular magnetic resonance (CMR) commonly rely on (i) electrocardiographic (ECG) gating yielding pseudo real-time cine representations, (ii) balanced gradient-echo sequences referred to as steady-state free precession (SSFP), and (iii) breath holding or respiratory gating. Problems may therefore be due to the need for a robust ECG signal, the occurrence of arrhythmia and beat to beat variations, technical instabilities (e.g., SSFP "banding" artefacts), and limited patient compliance and comfort. Here we describe a new approach providing true real-time CMR with image acquisition times as short as 20 to 30 ms or rates of 30 to 50 frames per second.
1 January 2013 in Journal of Cardiovascular Magnetic Resonance
While cardiovascular magnetic resonance (CMR) commonly employs ECG-synchronized cine acquisitions with balanced steady-state free precession (SSFP) contrast at 1.5 T, recent developments at 3 T demonstrate significant potential for T1-weighted real-time imaging at high spatiotemporal resolution using undersampled radial FLASH. The purpose of this work was to combine both ideas and to evaluate a corresponding real-time CMR method at 1.5 T with SSFP contrast.