29 May 2007 in Magnetic Resonance in Medicine
The reconstruction of artifact‐free images from radially encoded MRI acquisitions poses a difficult task for undersampled data sets, that is for a much lower number of spokes in k‐space than data samples per spoke. Here, we developed an iterative reconstruction method for undersampled radial MRI which (i) is based on a nonlinear optimization, (ii) allows for the incorporation of prior knowledge with use of penalty functions, and (iii) deals with data from multiple coils. The procedure arises as a two‐step mechanism which first estimates the coil profiles and then renders a final image that complies with the actual observations. Prior knowledge is introduced by penalizing edges in coil profiles and by a total variation constraint for the final image. The latter condition leads to an effective suppression of undersampling (streaking) artifacts and further adds a certain degree of denoising. Apart from simulations, experimental results for a radial spin‐echo MRI sequence are presented for phantoms and human brain in vivo at 2.9 T using 24, 48, and 96 spokes with 256 data samples. In comparison to conventional reconstructions (regridding) the proposed method yielded visually improved image quality in all cases. Magn Reson Med 57:1086–1098, 2007.
27 August 2010 in NMR in Biomedicine
24 August 2008 in Magnetic Resonance in Medicine
The use of parallel imaging for scan time reduction in MRI faces problems with image degradation when using GRAPPA or SENSE for high acceleration factors. Although an inherent loss of SNR in parallel MRI is inevitable due to the reduced measurement time, the sensitivity to image artifacts that result from severe undersampling can be ameliorated by alternative reconstruction methods. While the introduction of GRAPPA and SENSE extended MRI reconstructions from a simple unitary transformation (Fourier transform) to the inversion of an ill‐conditioned linear system, the next logical step is the use of a nonlinear inversion. Here, a respective algorithm based on a Newton‐type method with appropriate regularization terms is demonstrated to improve the performance of autocalibrating parallel MRI—mainly due to a better estimation of the coil sensitivity profiles. The approach yields images with considerably reduced artifacts for high acceleration factors and/or a low number of reference lines. Magn Reson Med, 2008.
20 July 2011 in Journal of Magnetic Resonance Imaging
Purpose: To develop a model‐based reconstruction technique for T2 mapping based on multi‐echo spin‐echo MRI sequences with highly undersampled Cartesian data encoding.Materials and Methods: The proposed technique relies on a nonlinear inverse reconstruction algorithm which directly estimates a T2 and spin‐density map from a train of undersampled spin echoes. The method is applicable to acquisitions with single receiver coils but benefits from multi‐element coil arrays. The algorithm is validated for trains of 16 spin echoes with a spacing of 10 to 12 ms using numerical simulations as well as human brain MRI at 3 Tesla (T).Results: When compared with a standard T2 fitting procedure using fully sampled T2‐weighted images, and depending on the available signal‐to‐noise ratio and number of coil elements, model‐based nonlinear inverse reconstructions for both simulated and in vivo MRI data yield accurate T2 estimates for undersampling factors of 5 to 10.Conclusion: This work describes a promising strategy for T2‐weighted MRI that simultaneously offers accurate T2 relaxation times and properly T2‐weighted images at arbitrary echo times. For a standard spin‐echo MRI sequence with Cartesian encoding, the method allows for a much higher degree of undersampling than obtainable by conventional parallel imaging. J. Magn. Reson. Imaging 2011;.
21 May 2010 in Magnetic Resonance in Medicine
A previously proposed nonlinear inverse reconstruction for autocalibrated parallel imaging simultaneously estimates coil sensitivities and image content. This work exploits this property for real‐time MRI, where coil sensitivities need to be dynamically adapted to the conditions generated by moving objects. The development comprises (i) an extension of the nonlinear inverse algorithm to non‐Cartesian k‐space encodings, (ii) its implementation on a graphical processing unit to reduce reconstruction times, and (iii) the use of a convolution‐based iteration, which considerably simplifies the graphical processing unit implementation compared to a gridding technique. The method is validated for real‐time MRI of the human heart at 3 T using radio frequency‐spoiled radial FLASH (pulse repetition time/echo time = 2.0/1.3 ms, flip angle 8°). The results demonstrate artifact‐free reconstructions from only 65–85 spokes, with 256 oversampled data points. Acquisition times of 130–170 ms resulted in 29–38 frames per second for sliding window reconstructions (factor 5). While offline reconstructions required 1–2 sec, real‐time applications with modified parameters and slightly lower image quality were achieved within 90 ms per graphical processing unit. Magn Reson Med 63:1456–1462, 2010.
13 April 2021 in Circulation
Background: Right heart catheterization using exercise stress is the reference standard for the diagnosis of heart failure with preserved ejection fraction (HFpEF) but carries the risk of the invasive procedure. We hypothesized that real-time cardiac magnetic resonance (RT-CMR) exercise imaging with pathophysiologic data at excellent temporal and spatial resolution may represent a contemporary noninvasive alternative for diagnosing HFpEF. Methods: The HFpEF-Stress trial (CMR Exercise Stress Testing in HFpEF; URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03260621. URL: https://dzhk.de/ ; Unique identifier: DZHK-17) prospectively recruited 75 patients with echocardiographic signs of diastolic dysfunction and dyspnea on exertion (E/e′>8, New York Heart Association class ≥II) to undergo echocardiography, right heart catheterization, and RT-CMR at rest and during exercise stress. HFpEF was defined according to pulmonary capillary wedge pressure (≥15 mm Hg at rest or ≥25 mm Hg during exercise stress). RT-CMR functional assessments included time–volume curves for total and early (1/3) diastolic left ventricular filling, left atrial (LA) emptying, and left ventricular/LA long axis strain. Results: Patients with HFpEF (n=34; median pulmonary capillary wedge pressure at rest, 13 mm Hg; at stress, 27 mm Hg) had higher E/e′ (12.5 versus 9.15), NT-proBNP (N-terminal pro–B-type natriuretic peptide; 255 versus 75 ng/L), and LA volume index (43.8 versus 36.2 mL/m 2 ) compared with patients with noncardiac dyspnea (n=34; rest, 8 mm Hg; stress, 18 mm Hg; P ≤0.001 for all). Seven patients were excluded because of the presence of non-HFpEF cardiac disease causing dyspnea on imaging. There were no differences in RT-CMR left ventricular total and early diastolic filling at rest and during exercise stress ( P ≥0.164) between patients with HFpEF and noncardiac dyspnea. RT-CMR revealed significantly impaired LA total and early ( P <0.001) diastolic emptying in patients with HFpEF during exercise stress. RT-CMR exercise stress LA long axis strain was independently associated with HFpEF (adjusted odds ratio, 0.657 [95% CI, 0.516–0.838]; P =0.001) after adjustment for clinical and imaging measures and emerged as the best predictor for HFpEF (area under the curve at rest 0.82 versus exercise stress 0.93; P =0.029). Conclusions: RT-CMR allows highly accurate identification of HFpEF during physiologic exercise and qualifies as a suitable noninvasive diagnostic alternative. These results will need to be confirmed in multicenter prospective research studies to establish widespread routine clinical use. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03260621. URL: https://dzhk.de/ ; Unique identifier: DZHK-17.