An integrated geological assessment of groundwater contamination was carried out to determine the nature of the subsurface as well as establish linkages between groundwater and contaminants in the vicinity of the Roundhill landfill, South Africa. Quantitative analysis involved measurement of physico-chemical properties of groundwater samples from two boreholes and a leachate pond within the landfill. Qualitative assessment involved combined measurements of electrical resistivity and time domain induced polarization (IP) across three profiles, using the double-dipole array. The physico-chemical analysis results show the presence of heavy metals (i.e.mercury, lead and arsenic) in groundwater samples in concentrations above the general acceptable limits. Perhaps, the high concentration of these metals could be due to the dumping of toxic and hazardous waste substances on the landfill, contrary to the landfill design and classification. Resistivity and IP pseudo-sections revealed a 4-layered earth structure and anomalous zones of resistivity (≤112 Ω-m) and low chargeability (≤1.25 ms) in the top layers. This is indicative of percolating leachate plume in the unsaturated zone. Despite the fact that layer lithologies and stratigraphy pose low risk to groundwater contamination, structural controls such as fractures in the bedrock are favourably disposed to the percolation of contaminants into the groundwater over time. Proper waste classification and inspection should be carried out on the landfill prior to waste disposal.
22 December 2019 in International Journal of Geophysics
A combination of electrical resistivity and induced polarization methods were applied to a solid waste landfill in Alice, Eastern Cape, South Africa to delineate the lithologic layers and locate possible leachate plumes. Resistivity and IP data were collected along six profiles; VES on two and the dipole-dipole configuration was used in the rest four. The result shows a 4-layered earth system with a shallow depth to the top of the bedrock (<10 m). Contaminants ranging from unsaturated waste with high ion content to dense aqueous phase liquid contaminants, characterized by low resistivity (34–80 Ohm-m) and low chargeability values (0.05–5.75 ms). The contamination was interpreted based on resistivity/IP anomalies considering the background geology. The shallow bedrock indicated a low risk to groundwater contamination because of its competent nature from its geology, and characteristic high resistivity values (≥1000 Ohm-m). However, the steep nature of the landfill terrain due to its location at the foot of a vertical slope favours the rapid migration of the contaminants into the immediate vicinity of the landfill. The construction of containment structures such as waste cells will help in enhancing effective waste management practices in the landfill.
Electrical resistivity imaging (ERI) surveys and physico-chemical analysis were carried out on a solid waste landfill (SWL) in Eastern Cape, South Africa to assess the impact of leachate pollution on groundwater quality. 2-D resistivity imaging was done across three profile lines (A, C and E) on the landfill. Physico-chemical properties of water samples from the leachate pond and boreholes (BH1 and BH2), located between 80 m to 200 m from the edge of the landfill were analysed. The results revealed groundwater contamination to a depth of about 75 m,well within the aquiferous zone. High electrical conductivity (EC) and total dissolve solid (TDS) values observed in the groundwater samples indicate a downward transfer of leachate into the groundwater. The difference in EC and TDS values for BH2 and BH1 (9892 μS/cm/ 4939 mg/L and 6988 μS/cm/ 3497 mg/L respectively), indicated that concentration of contaminants increased towards the centre of the landfill The direction of flow of the leachate is towards the southwestern part of the landfill. In the absence of a leachate recovery system, the uncontrolled accumulation of leachate over time at the landfill will pose a threat to the groundwater quality, hence the need to improve waste management practices in the study area to mitigate the effects of pollution
Analysis of water resources of this area was carried out in order to assessing the water quality by determining the concentrations of Cations, Anions, Heavy metals, Trace elements, PH, Alkalinity, Total Dissolved Solids and microbial loads in water samples. Ten (10) water samples were collected from the study area - samples each of rain water, two pond waters - 1 and 2, stream water, four (4) hand-dug wells, hand pump water and a motorized borehole. The results obtained were compared with WHO standards and it showed that all the cations in water samples are within the limits. The water samples at locations B, E, F, G, H, I, and J have high alkalinity and HC0-3 content. The heavy metals (Pb, Ni and Cd) and trace elements (Fe and Cu) are dominantly high in the surface waters. Microbiological substances in the water samples from the study area revealed indicator organisms higher than the WHO standard for drinking water. Samples obtained from location G, I and J recorded an absence of E. coli and are fit for human consumptions but needed to be treated due to high MPN (Most Probable Number) index of viable microorganisms as against WHO standard. This research showed that the water resources of the study area are gradually polluted and in the near future may not be good for drinking.