This paper proposes a new type of gangue filling body (GFB) to address the issues of the low stability, strength, poor shrinkage performance, and inadequate seepage resistance of paste filling materials in overburdened mining conditions, as well as the challenge of fully utilizing solid waste gangue. The coal gangue (CG), U-expanding agent (UEA), and amount of water added were kept constant, and the mass ratio of the various components was adjusted to the design. The standard for filling was assessed using slump tests, uniaxial compression tests, shrinkage tests, and penetration tests. A further microscopic analysis of the pastes with an optimal filling performance was conducted using SEM. The support pressure and overburden migration patterns in the GFBs were evaluated using Flac3D. The results indicate that the GFB with ratio 4 performed best, highlighting the significant role of Portland cement (OPC). The GFB with ratio 3 demonstrated the second-best performance, suggesting that GFBs with a higher early strength should be chosen to fill hollow zones for an effective filling outcome. This study introduced a new type of paste filling material and confirmed the rock transport law of this material under overburdened conditions using Flac3D, offering significant insights for the engineering field.
Backfilling is a promising measure for controlling surface subsidence in mined-out areas and disposing solid wastes from the mineral processing, there are increasing demands of enhanced toughness and anti-cracking properties of backfill materials to prolong the service life under the complex loads. In this study, polypropylene (PP) fibers were employed to improve performance of backfills, four-point bending and uniaxial compression tests were conducted to investigate the failure process and damage evolution of fiber-reinforced aeolian-sand backfill materials (FABs) using Digital Image Correlation (DIC) and Acoustic Emission (AE) techniques. The results show that the compressive strength tends to decrease with the increasing fiber volume fractions, while the four-point bending strength shows a tendency to increase initially and then decrease, and the optimum volume fraction of PP fiber is 0.6%. At the optimal fiber volume fraction, PP fibers with lengths of 3 mm and 9 mm resulted in a 65.25% and 81.62% increase in the four-point bending strength of FABs, respectively. As indicated by DIC measurements, PP fibers with a length of 9 mm were more effective in controlling the horizontal and vertical displacements of FABs under four-point bending loads than that of 3 mm, and the cracks developed more slowly at the same deflection. In addition, PP fibers with a length of 9 mm have stronger crack extension delay characteristics due to longer effective anchorage distance, as evidenced by more frequent acoustic emission ringing counts and higher cumulative ringing counts. The results of the study may provide a theoretical basis for the application of FABs materials in backfilling.
18 March 2026 in Construction and Building Materials