José Tomás Tomas Ortiz Pérez

Dr. José Tomás Tomas Ortiz Pérez

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2020 in Cells
Verified
Journal Article
Open access
PDF file
TATutusaus Anna
Tutusaus Anna
Montserrat MariMontserrat Mari
Montserrat Mari
JPJosé Tomás Tomas Ortiz Pérez
José Tomás Tomas Ortiz Pérez
GNGerry Nicolaes
Gerry Nicolaes
Albert MoralesAlbert Morales
Albert Morales
Pablo García de FrutosPablo García de Frutos
Pablo García de Frutos
The vitamin K-dependent factors protein S (PROS1) and growth-arrest-specific gene 6 (GAS6) and their tyrosine kinase receptors TYRO3, AXL, and MERTK, the TAM subfamily of receptor tyrosine kinases (RTK), are key regulators of inflammation and vascular response to damage. TAM signaling, which has largely studied in the immune system and in cancer, has been involved in coagulation-related pathologies. Because of these established biological functions, the GAS6-PROS1/TAM system is postulated to play an important role in SARS-CoV-2 infection and progression complications. The participation of the TAM system in vascular function and pathology has been previously reported. However, in the context of COVID-19, the role of TAMs could provide new clues in virus-host interplay with important consequences in the way that we understand this pathology. From the viral mimicry used by SARS-CoV-2 to infect cells, to the immunothrombosis that is associated with respiratory failure in COVID-19 patients, TAM signaling seems to be involved at different stages of the disease. TAM targeting is becoming an interesting biomedical strategy, which is useful for COVID-19 treatment now, but also for other viral and inflammatory diseases in the future.

4 January 2023 in EP Europace
Verified
Journal Article
Open access
PSPaula Sanchez-Somonte
Paula Sanchez-Somonte
PGPaz Garre
Paz Garre
Sara Vázquez-CalvoSara Vázquez-Calvo
Sara Vázquez-Calvo
LQLevio Quinto
Levio Quinto
RBRoger Borràs
Roger Borràs
IRIvo Roca-Luque
Ivo Roca-Luque
Aims: Heterogeneous tissue channels (HTCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular arrhythmias, but there are few published data about their arrhythmogenic characteristics.Methods and results: We enrolled 34 consecutive patients with ischaemic and non-ischaemic cardiomyopathy who were referred for ventricular tachycardia (VT) ablation. LGE-CMR was performed prior to ablation, and the HTCs were analyzed. Arrhythmogenic HTCs linked to induced VT were identified during the VT ablation procedure. The characteristics of arrhythmogenic HTCs were compared with those of non-arrhythmogenic HTCs. Three patients were excluded due to low-quality LGE-CMR images. A total of 87 HTCs were identified on LGE-CMR in 31 patients (age:63.8 ± 12.3 years; 96.8% male; left ventricular ejection fraction: 36.1 ± 10.7%). Of the 87 HTCs, only 31 were considered arrhythmogenic because of their relation to a VT isthmus. The HTCs related to a VT isthmus were longer [64.6 ± 49.4 vs. 32.9 ± 26.6 mm; OR: 1.02; 95% CI: (1.01–1.04); P < 0.001] and had greater mass [2.5 ± 2.2 vs. 1.2 ± 1.2 grams; OR: 1.62; 95% CI: (1.18–2.21); P < 0.001], a higher degree of protectedness [26.19 ± 19.2 vs. 10.74 ± 8.4; OR 1.09; 95% CI: (1.04–1.14); P < 0.001], higher transmurality [number of wall layers with CCs: 3.8 ± 2.4 vs. 2.4 ± 2.0; OR: 1.31; 95% CI: (1.07–1.60); P = 0.008] and more ramifications [3.8 ± 2.0 vs. 2.7 ± 1.1; OR: 1.59; 95% CI: (1.15–2.19); P = 0.002] than non-arrhythmogenic HTCs. Multivariate logistic regression analysis revealed that protectedness was the strongest predictor of arrhythmogenicity.Conclusion: The protectedness of an HTC identified by LGE-CMR is strongly related to its arrhythmogenicity during VT ablation.

23 January 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
SVSara Vázquez-Calvo
Sara Vázquez-Calvo
JCJudit Mas Casanovas
Judit Mas Casanovas
PGPaz Garre
Paz Garre
PSPaula Sánchez-Somonte
Paula Sánchez-Somonte
PFPasquale Valerio Falzone
Pasquale Valerio Falzone
IRIvo Roca-Luque
Ivo Roca-Luque
Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.

16 May 2024 in JACC: Clinical Electrophysiology
Verified
Journal Article
Open access
JGJean-Baptiste Guichard
Jean-Baptiste Guichard
MRMariona Regany-Closa
Mariona Regany-Closa
Sara Vázquez-CalvoSara Vázquez-Calvo
Sara Vázquez-Calvo
BZBlanca Zazu
Blanca Zazu
BSBerta Pellicer Sendra
Berta Pellicer Sendra
IRIvo Roca-Luque
Ivo Roca-Luque
A partial delineation of targets for ablation of ventricular tachycardia (VT) during a stable rhythm is likely responsible for a suboptimal success rate. The abnormal low-voltage near-field functional components may be hidden within the high-amplitude far-field signal. The aim of this study was to evaluate the benefit and feasibility of functional substrate mapping using a full-ventricle S3 protocol and to assess its colocalization with arrhythmogenic conducting channels (CCs) on late gadolinium enhancement cardiac magnetic resonance. An S3 mapping protocol with a drive train of S1 followed by S2 (effective refractory period + 30 ms) and S3 (effective refractory period + 50 ms) from the right ventricular apex was performed in 40 consecutive patients undergoing scar-related VT ablation. Deceleration zones (DZs) and areas of late potentials (LPs) were identified for all maps. A preprocedural noninvasive substrate assessment was done using late gadolinium enhancement cardiac magnetic resonance and postprocessing with automated CC identification. The S3 protocol was completed in 34 of the 40 procedures (85.0%). The S3 protocol enhanced the identification of VT isthmus on the basis of DZ (89% vs 62%; P < 0.01) and LP (93% vs 78%; P = 0.04) assessment. The percentage of CCs unmasked by DZs and LPs using S3 maps was significantly higher than the ones using S2 and S1 maps (78%, 65%, and 48% [P < 0.001] and 88%, 81%, and 68% [P < 0.01], respectively). The functional substrate identified during S3 activation mapping was significantly more extensive than the one identified using S2 and S1, including a greater number of DZs (2.94, 2.47, and 1.82, respectively; P < 0.001) and a wider area of LPs (44.1, 38.2, and 29.4 cm2, respectively; P < 0.001). After VT ablation, 77.9% of patients have been VT free during a median follow-up period of 13.6 months. The S3 protocol was feasible in 85% of patients, allows a better identification of targets for ablation, and might improve VT ablation results.

1 May 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
GFGiulio Falasconi
Giulio Falasconi
DPDiego Penela
Diego Penela
DSDavid Soto-Iglesias
David Soto-Iglesias
PFPietro Francia
Pietro Francia
CTCheryl Teres
Cheryl Teres
ABAntonio Berruezo
Antonio Berruezo
Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50–67), fluoroscopy time was 43 s (IQR 20–71), and radiofrequency (RF) time was 16.5 min (IQR 14.3–18.4). The median AI tailored to the local LAWT was 387 (IQR 360–410) for the anterior wall and 335 (IQR 300–375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).

30 March 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
GFGiulio Falasconi
Giulio Falasconi
DPDiego Penela
Diego Penela
DSDavid Soto-Iglesias
David Soto-Iglesias
PFPietro Francia
Pietro Francia
ASAndrea Saglietto
Andrea Saglietto
ABAntonio Berruezo
Antonio Berruezo
Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.