Ana Cravo Sá

Dr. Ana Cravo Sá

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
ASAna Cravo Sá
Ana Cravo Sá
AFAna Fermento
Ana Fermento
DNDalila Neves
Dalila Neves
SFSara Ferreira
Sara Ferreira
TSTeresa Silva
Teresa Silva
EBEmmanuel Bonnarens
Emmanuel Bonnarens
Aim: In this study, we intend to compare two different setup procedures for female breast cancer patients. Background: Imaging in radiotherapy provides a precise localization of the tumour, increasing the accuracy of the treatment delivery in breast cancer. Materials and methods: Twenty breast cancer patients who underwent whole breast radiotherapy (WBRT) were selected for this study. Patients were divided into two groups of ten. Group one (G1) was positioned by tattoos and then the patient positioning was adjusted with the aid of AlignRT (Vision RT, London, UK). In group two (G2), patients were positioned only by tattoos. For both groups, the first 15 fractions were analyzed, a daily kilovoltage (kV) cone beam computed tomography (CBCT) image was made and then the rotational and translational displacements and, posteriorly, the systematic (X') and random (a) errors were analyzed. Results: The comparison of CBCT displacements for the two groups showed a statistically significant difference in the translational left-right (LR) direction (p= 0.03), considering that the procedure with AlignRT system has smaller lateral displacements. The results of systematic (X') and random (a) errors showed that for translational displacements the group positioned only by tattoos (G2) demonstrated higher values of errors when compared with the group positioned with the aid of AlignRT (G1). Conclusions: AlignRT could help the positioning of breast cancer patients; however, it should be used with another imaging method. (C) 2018 Greater Poland Cancer Centre. Published by Elsevier Sp. z o.o. All rights reserved.

1 March 2020 in Physica Medica
Verified
Journal Article
Closed access
ASAna Cravo Sá
Ana Cravo Sá
ABAndreia Barateiro
Andreia Barateiro
BBBryan Bednarz
Bryan Bednarz
CBCecília Borges
Cecília Borges
JPJoana Pereira
Joana Pereira
YRYuriy Romanets
Yuriy Romanets

21 February 2025 in Physica Medica
Verified
Journal Article
Closed access
MDMario Djukelic
Mario Djukelic
CMColin John John Martin
Colin John John Martin
AAAbdullah Abuhaimed
Abdullah Abuhaimed
Tomas KronTomas Kron
Tomas Kron
SGSebastien Gros
Sebastien Gros
WSWilliam C. Small
William C. Small

5 August 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
ASAna Cravo Sá
Ana Cravo Sá
ABAndreia Barateiro
Andreia Barateiro
BBBryan P. Bednarz
Bryan P. Bednarz
PAPedro Almeida
Pedro Almeida
PVPedro Vaz
Pedro Vaz
TMTiago Madaleno
Tiago Madaleno
3DCRT and IMRT out-of-field doses in pediatric patients were compared using Monte Carlo simulations with treatment planning system calculations and measurements.Purpose: Out-of-field doses are given to healthy tissues, which may allow the development of second tumors. The use of IMRT in pediatric patients has been discussed, as it leads to a “bath” of low doses to large volumes of out-of-field organs and tissues. This study aims to compare out-of-field doses in pediatric patients comparing IMRT and 3DCRT techniques using measurements, Monte Carlo (MC) simulations, and treatment planning system (TPS) calculations.Materials and methods: A total dose of 54 Gy was prescribed to a PTV in the brain of a pediatric anthropomorphic phantom, for both techniques. To assess the out-of-field organ doses for both techniques, two treatment plans were performed with the 3DCRT and IMRT techniques in TPS. Measurements were carried out in a LINAC using a pediatric anthropomorphic phantom and thermoluminescent dosimeters to recreate the treatment plans, previously performed in the TPS. A computational model of a LINAC, the associated multileaf collimators, and a voxelized pediatric phantom implemented in the Monte Carlo N-Particle 6.1 computer program were also used to perform MC simulations of the out-of-field organ doses, for both techniques.Results: The results obtained by measurements and MC simulations indicate a significant increase in dose using the IMRT technique when compared to the 3DCRT technique. More specifically, measurements show higher doses with IMRT, namely, in right eye (13,041 vs. 593 mGy), left eye (6,525 vs. 475 mGy), thyroid (79 vs. 70 mGy), right lung (37 vs. 28 mGy), left lung (27 vs. 20 mGy), and heart (31 vs. 25 mGy). The obtained results indicate that out-of-field doses can be seriously underestimated by TPS.Discussion: This study presents, for the first time, out-of-field dose measurements in a realistic scenario and calculations for IMRT, centered on a voxelized pediatric phantom and an MC model of a medical LINAC, including MLC with log file-based simulations. The results pinpoint significant discrepancies in out-of-field doses for the two techniques and are a cause of concern because TPS calculations cannot accurately predict such doses. The obtained doses may presumably increase the risk of development of second tumors.

21 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DRDaniela Ribeiro
Daniela Ribeiro
ASAna Cravo Sá
Ana Cravo Sá
Elisabete CarolinoElisabete Carolino
Elisabete Carolino
LMLeonor Santos Martins
Leonor Santos Martins
MBMargarida Borrego
Margarida Borrego
Introduction: Radiotherapy can impact on patients’ reproductive organs and fertility. This study aims (i) to assess whether the doses to the gonads of 70 patients met the tolerance doses used in radiotherapy planning; (ii) to compare Three-Dimensional Conformal Radiotherapy (3DCRT) with Volumetric Modulated Arc Therapy (VMAT) techniques; and (iii) to verify if ovarian transposition reduces the dose to the ovaries. Methods: A retrospective analysis of 70 patients aged 45 or under who underwent pelvic radiotherapy between 2014 and 2023 in a radiotherapy department was carried out. The dose constraints considered were derived from the Dose-Volume Constraints for Organs at Risk in Radiotherapy project. Results: The average number of children of all the patients in the study was 1.25 and the standard deviation was 1.40. No statistically significant differences were detected regarding the doses to the left and right gonads between 3DCRT and VMAT (p > 0.05). There were statistically significant differences between female patients who underwent ovarian transposition and those who did not undergo ovarian transposition regarding the maximum and medium doses in both right and left ovaries (p < 0.05), with a dose reduction that could reduce doses by an average of up to 39 Gy. Conclusions: In the total sample, 58.6% of patients were treated with VMAT, only 18.6% met the maximum dose limits, and 22.9% met the average dose constraints. Only five women underwent ovarian transposition, which proved effective in meeting dose constraints and significantly reducing the dose to the ovaries.

9 October 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
ASAna Cravo Sá
Ana Cravo Sá
ABAndreia Barateiro
Andreia Barateiro
BBBryan P. Bednarz
Bryan P. Bednarz
PAPedro Almeida
Pedro Almeida
PVPedro Vaz
Pedro Vaz
TMTiago Madaleno
Tiago Madaleno
Corrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements