Dea Dundara Debeljuh

Ms. Dea Dundara Debeljuh

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Physica Medica
Verified
Journal Article
Closed access
DDDea Dundara Debeljuh
Dea Dundara Debeljuh
Slaven JurkovićSlaven Jurković
Slaven Jurković
IPIvan Pribanić
Ivan Pribanić
FPFrano Poljak
Frano Poljak
IKIvana Kralik
Ivana Kralik
JVJenia Vassileva
Jenia Vassileva

1 December 2020 in Nuclear Technology and Radiation Protection
Verified
Journal Article
Open access
PDF file
DDDea Dundara Debeljuh
Dea Dundara Debeljuh
SJSlaven Jurkovic
Slaven Jurkovic
IPIvan Pribanic
Ivan Pribanic
NGNeva Girotto
Neva Girotto
SGSvjetlana Grbac-Ivankovic
Svjetlana Grbac-Ivankovic
DSDoris Segota
Doris Segota
Dose assessment of diagnostic nuclear medicine procedures is necessary to further optimize respective procedure, estimate radiation risk, improve radiation safety and verify compliance of local practice with guide lines. In line with Council Directive 2013/59/EURATOM, patient medical documentation should include information related to radiation exposure. The aim of this work is to present the patient radiation dose assessment system designed for routine clinical use, that uses in-house designed worksheets for dose calculation based on relevant parameters introduced by the ICRP publications. Dose reports provide information about the absorbed dose delivered to the target and non-target organs of interest and the effective dose for each diagnostic procedure. The data from the dose reports was used to investigate average patient exposure levels during a one-year period and the results are presented. The implemented system has improved the quality of services provided and understanding of radiation risks. Moreover, the presented results have stimulated further optimization of nuclear medicine processes.

14 March 2022 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Open access
PDF file
MKManda Švabić Kolacio
Manda Švabić Kolacio
DRDavid Rajlić
David Rajlić
MRMilan Radojčić
Milan Radojčić
ÐRÐeni Smilović Radojčić
Ðeni Smilović Radojčić
NONevena Obajdin
Nevena Obajdin
Slaven JurkovićSlaven Jurković
Slaven Jurković
Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSCLC) patients. NSCLC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice. Materials and methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed. Results: Statistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS. Conclusion: All investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used. Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSCLC) patients. NSCLC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice. Materials and methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed. Results: Statistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS. Conclusion: All investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used.

18 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DDDea Dundara Debeljuh
Dea Dundara Debeljuh
RMRoberta Matheoud
Roberta Matheoud
IPIvan Pribanić
Ivan Pribanić
MBMarco Brambilla
Marco Brambilla
Slaven JurkovićSlaven Jurković
Slaven Jurković
A comprehensive validation of data acquired by different myocardial perfusion imaging (MPI) systems was performed to evaluate contrast, self-attenuation properties, and perfusion detection capability. An anthropomorphic phantom with a myocardial insert and perfusion defect was used to simulate 99mTc-tetrofosmin distribution. Different MPI systems were evaluated: a SPECT system with iterative reconstruction algorithms and resolution recovery (IRR) with/without scatter correction (SPECT-IRR-SC and SPECT-IRR), and a cardio-centric IQ SPECT/CT system with IRR, with/without scatter and attenuation corrections (IQ-IRR-SC-AC and IQ-IRR). The image quality was assessed through physical descriptors: the contrast between the left ventricular (LV) wall and LV inner chamber (CLV/LVIC), intrinsic contrast (IC), and net contrast (NC). CLV/LVIC was found to be superior for IQ-IRR-SC-AC. The IC results showed non-uniformity of the signal intensity in the LV wall for the SPECT systems. The lowest IC values were obtained for IQ-IRR-SC-AC, except for septal position, where an underestimation of the signal intensity was revealed. The NC was found to be the highest for IQ-IRR-SC-AC and SPECT-IRR-SC. Additionally, for IQ-IRR-SC-AC, the NC increased in posterior and septal positions compared to IQ-IRR, enabling better perfusion detection capability over short-axis images. IQ-IRR showed performances comparable to SPECT-IRR. The characterization and evaluation perfusion detection capability of the MPI systems enabled the investigation of the systems’ performance and limitations.