The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers’ roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. Comparison of the radiographers’ and clinicians’ contours resulted in a median (range) DSC of 0.92 (0.86 – 0.99), median (range) MDA of 0.98 mm (0.2–1.7) and median (range) HD of 6.3 mm (2.5–11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians’ offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88–1.0), median (range) MDA was 0.8 mm (0.04–1.18) and HD was 5.15 mm (2.09–8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians’ offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.
30 November 2016 in Journal of Applied Clinical Medical Physics
Objectives: To reduce treatment planning times while maintaining plan quality through the introduction of semi‐automated planning techniques for breast radiotherapy.Methods: Automatic critical structure delineation was examined using the Smart Probabilistic Image Contouring Engine (SPICE) commercial autosegmentation software (Philips Radiation Oncology Systems, Fitchburg, WI) for a cohort of ten patients. Semiautomated planning was investigated by employing scripting in the treatment planning system to automate segment creation for breast step‐and‐shoot planning and create objectives for segment weight optimization; considerations were made for three different multileaf collimator (MLC) configurations. Forty patients were retrospectively planned using the script and a planning time comparison performed.Results: The SPICE heart and lung outlines agreed closely with clinician‐defined outlines (median Dice Similarity Coefficient > 0.9); median difference in mean heart dose was 0.0 cGy (range −10.8 to 5.4 cGy). Scripted treatment plans demonstrated equivalence with their clinical counterparts. No statistically significant differences were found for target parameters. Minimal ipsilateral lung dose increases were also observed. Statistically significant (P < 0.01) time reductions were achievable for MLCi and Agility MLC (Elekta Ltd, Crawley, UK) plans (median 4.9 and 5.9 min, respectively).Conclusions: The use of commercial autosegmentation software enables breast plan adjustment based on doses to organs at risk. Semi‐automated techniques for breast radiotherapy planning offer modest reductions in planning times. However, in the context of a typical department's breast radiotherapy workload, minor savings per plan translate into greater efficiencies overall.
The topographic relationship between previously identified medullary ventral surface respiratory chemosensitive regions and brain surface extracellular fluid (ECF) acid production during acute hypoxia was explored in anesthetized, paralyzed, and artificially ventilated cats. Glass pH electrodes (0.8-mm diam, sheathed in stainless steel tubing) were mounted in mechanical contact with surfaces of medullary surface or adjacent pyramids, pons, spinal cord, or parietal cortex. Isocapnic hypoxia of 5 min [at arterial O2 saturation (SaO2) = 48 +/- 10%] reduced pH over rostral (Mitchell) and caudal (Loeschcke) areas by 0.12 +/- 0.09 and 0.07 +/- 0.04, respectively (n = 10, P < 0.05). Change in pH (delta pH) was proportional to desaturation with slopes 100 delta pH/delta SaO2 of 0.45 (rostral) and 0.20 (caudal) (R = 0.91 and 0.88, respectively). pH drop usually began within 3 min of hypoxia, became stable between 5 and 15 min, began to rise within 2 min of reoxygenation, and returned to control within 10 min. During equally hypoxic tests, intermediate area (Schlafke), pons, and spinal cord surfaces showed no significant acid shift. Parietal cortex ECF pH dropped more slowly but steadily by 0.079 +/- 0.034 during 20 min at SaO2 = 50% after a small but significant initial alkaline shift, and acidification of cortical surface continued for > 5 min after reoxygenation. We conclude that medullary ventral chemosensitive regions produce more lactic acid during hypoxia than neighboring brain surfaces.(ABSTRACT TRUNCATED AT 250 WORDS)
Neoadjuvant chemoradiotherapy followed by surgery is the mainstay of treatment for patients with rectal cancer. Standard clinical target volume (CTV) to planning target volume (PTV) margins of 10 mm are used to accommodate inter- and intrafraction motion of target. Treating on magnetic resonance-integrated linear accelerators (MR-linacs) allows for online manual recontouring and adaptation (MRgART) enabling the reduction of PTV margins. The aim of this study was to investigate motion of the primary CTV (CTVA; gross tumour volume and macroscopic nodes with 10 mm expansion to cover microscopic disease) in order to develop a simultaneous integrated boost protocol for use on MR-linacs. Patients suitable for neoadjuvant chemoradiotherapy were recruited for treatment on MR-linac using a two-phase technique; only the five phase 1 fractions on MR-linac were used for analysis. Intrafraction motion of CTVA was measured between pre-treatment and post-treatment MRI scans. In MRgART, isotropically expanded pre-treatment PTV margins from 1 to 10 mm were rigidly propagated to post-treatment MRI to determine overlap with 95% of CTVA. The PTV margin was considered acceptable if overlap was >95% in 90% of fractions. To understand the benefit of MRgART, the same methodology was repeated using a reference computed tomography planning scan for pre-treatment imaging. In total, nine patients were recruited between January 2018 and December 2020 with T3a-T4, N0-N2, M0 disease. Forty-five fractions were analysed in total. The median motion across all planes was 0 mm, demonstrating minimal intrafraction motion. A PTV margin of 3 and 5mm was found to be acceptable in 96 and 98% of fractions, respectively. When comparing to the computed tomography reference scan, the analysis found that PTV margins to 5 and 10 mm only acceptably covered 51 and 76% of fractions, respectively. PTV margins can be reduced to 3-5 mm in MRgART for rectal cancer treatment on MR-linac within an simultaneous integrated boost protocol.
1 November 2014 in Efficacy and Mechanism Evaluation
Background: Whole-breast radiotherapy (WBRT) is the standard treatment for breast cancer following breast-conserving surgery. Evidence shows that tumour recurrences occur near the original cancer: the tumour bed. New treatment developments include increasing dose to the tumour bed during WBRT (synchronous integrated boost) and irradiating only the region around the tumour bed, for patients at high and low risk of tumour recurrence, respectively. Currently, standard imaging uses bony anatomy to ensure accurate delivery of WBRT. It is debatable whether or not more targeted treatments such as synchronous integrated boost and partial-breast radiotherapy require image-guided radiotherapy (IGRT) focusing on implanted tumour bed clips (clip-based IGRT).Objectives: Primary – to compare accuracy of patient set-up using standard imaging compared with clip-based IGRT. Secondary – comparison of imaging techniques using (1) tumour bed radiotherapy safety margins, (2) volume of breast tissue irradiated around tumour bed, (3) estimated breast toxicity following development of a normal tissue control probability model and (4) time taken.Design: Multicentre observational study embedded within a national randomised trial: IMPORT-HIGH (Intensity Modulated and Partial Organ Radiotherapy – HIGHer-risk patient group) testing synchronous integrated boost and using clip-based IGRT.Setting: Five radiotherapy departments, participating in IMPORT-HIGH.Participants: Two-hundred and eighteen patients receiving breast radiotherapy within IMPORT-HIGH.Interventions: There was no direct intervention in patients’ treatment. Experimental and control intervention were clip-based IGRT and standard imaging, respectively. IMPORT-HIGH patients received clip-based IGRT as routine; standard imaging data were obtained from clip-based IGRT images.Main outcome measures: Difference in (1) set-up errors, (2) safety margins, (3) volume of breast tissue irradiated, (4) breast toxicity and (5) time, between clip-based IGRT and standard imaging.Results: The primary outcome of overall mean difference in clip-based IGRT and standard imaging using daily set-up errors was 2–2.6 mm (p < 0.001). Heterogeneity testing between centres found a statistically significant difference in set-up errors at one centre. For four centres (179 patients), clip-based IGRT gave a mean decrease in the systematic set-up error of between 1 mm and 2 mm compared with standard imaging. Secondary outcomes were as follows: clip-based IGRT and standard imaging safety margins were less than 5 mm and 8 mm, respectively. Using clip-based IGRT, the median volume of tissue receiving 95% of prescribed boost dose decreased by 29 cm3(range 11–193 cm3) compared with standard imaging. Difference in median time required to perform clip-based IGRT compared with standard imaging was X-ray imaging technique dependent (range 8–76 seconds). It was not possible to estimate differences in breast toxicity, the normal tissue control probability model indicated that for breast fibrosis maximum radiotherapy dose is more important than volume of tissue irradiated.Conclusions and implications for clinical practice: Margins of less than 8 mm cannot be used safely without clip-based IGRT for patients receiving concomitant tumour bed boost, as there is a risk of geographical miss of the tumour bed being treated. In principle, smaller but accurately placed margins may influence local control and toxicity rates, but this needs to be evaluated from mature clinical trial data in the future.Funding: The National Institute for Health Research Efficacy and Mechanism Evaluation programme.