3 January 2023 in Radiotherapy and Oncology
The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers’ roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. Comparison of the radiographers’ and clinicians’ contours resulted in a median (range) DSC of 0.92 (0.86 – 0.99), median (range) MDA of 0.98 mm (0.2–1.7) and median (range) HD of 6.3 mm (2.5–11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians’ offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88–1.0), median (range) MDA was 0.8 mm (0.04–1.18) and HD was 5.15 mm (2.09–8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians’ offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.
3 November 2022 in Clinical Oncology
Neoadjuvant chemoradiotherapy followed by surgery is the mainstay of treatment for patients with rectal cancer. Standard clinical target volume (CTV) to planning target volume (PTV) margins of 10 mm are used to accommodate inter- and intrafraction motion of target. Treating on magnetic resonance-integrated linear accelerators (MR-linacs) allows for online manual recontouring and adaptation (MRgART) enabling the reduction of PTV margins. The aim of this study was to investigate motion of the primary CTV (CTVA; gross tumour volume and macroscopic nodes with 10 mm expansion to cover microscopic disease) in order to develop a simultaneous integrated boost protocol for use on MR-linacs. Patients suitable for neoadjuvant chemoradiotherapy were recruited for treatment on MR-linac using a two-phase technique; only the five phase 1 fractions on MR-linac were used for analysis. Intrafraction motion of CTVA was measured between pre-treatment and post-treatment MRI scans. In MRgART, isotropically expanded pre-treatment PTV margins from 1 to 10 mm were rigidly propagated to post-treatment MRI to determine overlap with 95% of CTVA. The PTV margin was considered acceptable if overlap was >95% in 90% of fractions. To understand the benefit of MRgART, the same methodology was repeated using a reference computed tomography planning scan for pre-treatment imaging. In total, nine patients were recruited between January 2018 and December 2020 with T3a-T4, N0-N2, M0 disease. Forty-five fractions were analysed in total. The median motion across all planes was 0 mm, demonstrating minimal intrafraction motion. A PTV margin of 3 and 5mm was found to be acceptable in 96 and 98% of fractions, respectively. When comparing to the computed tomography reference scan, the analysis found that PTV margins to 5 and 10 mm only acceptably covered 51 and 76% of fractions, respectively. PTV margins can be reduced to 3-5 mm in MRgART for rectal cancer treatment on MR-linac within an simultaneous integrated boost protocol.
1 March 2020 in Technical Innovations & Patient Support in Radiation Oncology
The MR-Linac (MRL) provides a novel treatment modality that enables online adaptive treatments, but also creates new challenges for patient positioning in a laser-free environment. The accuracy and duration of prostate patient set-up on the MRL using two different methods for patient alignment was determined to establish standard of practice on the MRL. Differences in set-up accuracy were significant in the longitudinal direction and are accounted for in online plan adaption. Both methods recorded similar set-up times. The vendor recommended alignment method involves less manipulation of the patient and will be adopted as the standard positioning method for prostate and other pelvic patients on the MRL in future.
6 August 2022 in Clinical and Translational Radiation Oncology
The prostate demonstrates inter- and intra- fractional changes and thus adaptive radiotherapy would be required to ensure optimal coverage. Daily adaptive radiotherapy for MRI-guided radiotherapy can be both time and resource intensive when structure delineation is completed manually. Contours can be auto-generated on the MR-Linac via a deformable image registration (DIR) based mapping process from the reference image. This study evaluates the performance of automatically generated target structure contours against manually delineated contours by radiation oncologists for prostate radiotherapy on the Elekta Unity MR-Linac. Plans were generated from prostate contours propagated by DIR and rigid image registration (RIR) for forty fractions from ten patients. A two-dose level SIB (simultaneous integrated boost) IMRT plan is used to treat localised prostate cancer; 6000 cGy to the prostate and 4860 cGy to the seminal vesicles. The dose coverage of the PTV 6000 and PTV 4860 created from the manually drawn target structures was evaluated with each plan. If the dose objectives were met, the plan was considered successful in covering the gold standard (clinician-delineated) volume. The mandatory PTV 6000 dose objective (D98% > 5580 cGy) was met in 81 % of DIR plans and 45 % of RIR plans. The SV were mapped by DIR only and for all the plans, the PTV 4860 dose objective met the optimal target (D98% > 4617 cGy). The plans created by RIR led to under-coverage of the clinician-delineated prostate, predominantly at the apex or the bladder-prostate interface. Plans created from DIR propagation of prostate contours outperform those created from RIR propagation. In approximately 1 in 5 DIR plans, dosimetric coverage of the gold standard PTV was not clinically acceptable. Thus, at our institution, we use a combination of DIR propagation of contours alongside manual editing of contours where deemed necessary for online treatments.
17 June 2025 in Clinical and Translational Radiation Oncology
One barrier to wider clinical implementation of online MRI-guided radiotherapy (MRIgRT) on the MR Linac (MRL) is resource intensity. Specifically, the requirement for a clinical oncologist/radiation oncologist (CO/RO) to perform online contouring each fraction. We report an evaluation of therapeutic radiographer (RTT) online contouring for patients receiving whole bladder MRIgRT. RTTs undertook a contouring training programme. RTT and CO/RO clinical target volume (CTV) contours from 95 fractions were assessed using dice similarity coefficient (DSC), hausdorff distance (HD), mean distance to agreement (MDA), sensitivity and specificity volume metrics on the Raystation treatment planning system (TPS) (RaySearch Laboratories). Additionally, CTV DSC was evaluated with respect to a simultaneous truth and performance level estimation (STAPLE) generated in ADMIRE (Elekta AB, Stockholm, Sweden). In dosimetric analysis (Monaco, Elekta AB), online adaptive treatment plans, which had been generated using RTT-defined contours, were evaluated using contours delineated offline by CO/ROs. Comparison of RTT versus CO/RO contours found the CTV median (interquartile range) (IQR) for DSC was 0.92 (0.91–0.94), MDA was 0.11 (0.09–0.12) cm, and HD was 0.63 (0.53–0.72) cm, sensitivity and specificity were 0.94 (0.90–0.96) and 0.95 (0.92–0.97) respectively. In dosimetric analysis, 65 % (30/46) plans met optimal PTV coverage of V52.25 Gy > 98 % and all plans met mandatory PTV coverage of V52.25 Gy > 95 %. Following effective training, evaluation results demonstrate RTT whole bladder CTV contours to be comparable to CO/RO contours. Clinical implementation will release CO/ROs from MRL bladder treatments, reducing resource intensity of online workflows.
21 July 2025 in Technical Innovations & Patient Support in Radiation Oncology
Head and neck cancer (HNC) treatment on the Unity MR-Linac (MRL) (Elekta AB, Stockholm, Sweden) has been developed using the novel adapt-to-shape Lite (ATS-lite) method to create clinically acceptable adaptive treatments clinician-free. Here we investigate patient experience and acceptability of this technique. Ten HNC patients treated to 65 Gy in 30 fractions with MRI-guided adaptive radiotherapy (MRIgART) within the PERMIT trial (NCT03727698), were included. Data collected comprised patient demographics, treatment time, and patient experience, using an established MRL questionnaire. Back-up plans were created for use on the conventional linac with CT guidance, to prevent missed fractions. The frequency of use was collected and categorised to reflect the cause. The median total treatment time for ATS-lite method was 39 min. The percentage of treatments under 60 mins was 98.8 %. Questionnaire response rate was 85% and individual question response rate was 99%. Ninety-six percent of responses scored 2 or 3 on the Likert scale, a positive answer. The lowest scoring question was “I forced myself to manage the situation,” with a mean (SD) of 2.4 (0.9). The MRL delivered 84.7 % of treatments. The back-up plan was used for 46 fractions, 7 attributed to patient tolerance (n = 2 patients). Average treatment times for the ATS-lite HNC MRIgART are acceptable and faster than reported ATP treatment times. Patient-reported experience was extremely positive. Use of back-up plans attributable to lack of patient tolerance was low. This technique can used with the confidence that patient experience is not negatively impacted.