Adrian Robert Harvey

Dr. Adrian Robert Harvey

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2005 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Open access
PDF file
AHAdrian Robert Harvey
Adrian Robert Harvey
NTN. P. Thomas
N. P. Thomas
AAA. A. Amis
A. A. Amis

17 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SASamira Al-Nasser
Samira Al-Nasser
SNSiamak Noroozi
Siamak Noroozi
AHAdrian Robert Harvey
Adrian Robert Harvey
NANavid Aslani
Navid Aslani
RHRoya Haratian
Roya Haratian
Using tibial sensors in total knee replacements (TKRs) can enhance patient outcomes and reduce early revision surgeries, benefitting hospitals, the National Health Services (NHS), stakeholders, biomedical companies, surgeons, and patients. Having a sensor that is accurate, precise (over the whole surface), and includes a wide range of loads is important to the success of joint force tracking. This research aims to investigate the accuracy of a novel intraoperative load sensor for use in TKRs. This research used a self-developed load sensor and artificial intelligence (AI). The sensor is compatible with Zimmer’s Persona Knee System and adaptable to other knee systems. Accuracy and precision were assessed, comparing medial/lateral compartments inside/outside the sensing area and below/within the training load range. Five points were tested on both sides (medial and lateral), inside and outside of the sensing region, and with a range of loads. The average accuracy of the sensor was 83.41% and 84.63% for the load and location predictions, respectively. The highest accuracy, 99.20%, was recorded from inside the sensing area within the training load values, suggesting that expanding the training load range could enhance overall accuracy. The main outcomes were that (1) the load and location predictions were similar in accuracy and precision (p > 0.05) in both compartments, (2) the accuracy and precision of both predictions inside versus outside of the triangular sensing area were comparable (p > 0.05), and (3) there was a significant difference in the accuracy of load and location predictions (p < 0.05) when the load applied was below the training loading range. The intraoperative load sensor demonstrated good accuracy and precision over the whole surface and over a wide range of load values. Minor improvements to the software could greatly improve the results of the sensor. Having a reliable and robust sensor could greatly improve advancements in all joint surgeries.

23 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
SASamira Al-Nasser
Samira Al-Nasser
SNSiamak Noroozi
Siamak Noroozi
AHAdrian Robert Harvey
Adrian Robert Harvey
Intraoperative load sensors have been developed with the aim of balancing the soft tissue in the knee during Total Knee Replacements (TKRs). Literature has shown success in soft tissue bal-ancing however, concerns regarding the accuracy of these sensors remain. For this reason, pre-vious research has attempted to create robust sensors for intraoperative use. The design of the sensor in this research has aimed to address the concerns outlined in the literature to create a new and novel smart-sensor for soft-tissue balancing. This new intraoperative load sensor included design features to increase accuracy while artificial intelligence allowed for comprehensive sensing across the entirety of the sensor, providing unparalleled insight during the operation. Notably, the sensor was designed to withstand loads of at least 450 N, ensuring robust perfor-mance of the sensor. To optimize the design process while minimizing cost, Finite Element Analysis was employed. This approach ensured the design features fulfilled their function while maintaining structural integrity to withstand loads. Moreover, the novelty of using training data from simulated data will reduce the iterative process of the labor-intensive collection of training data for the artificial intelligence while reducing human error associated with it. Results from the evaluation demonstrated the ability of this design to successfully bridge the current gap in the market by fulfilling all essential design criteria established within the literature. This innovative smart-sensing tool will in turn enhance patient outcomes and alleviate financial burdens to pa-tients and the healthcare systems by reducing the need for early revision surgeries associated with improper joint tension.