Jelmer Braaksma

Mr. Jelmer Braaksma

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2023 in American Journal of Physical Medicine & Rehabilitation
Verified
Journal Article
Open access
JBJelmer Braaksma
Jelmer Braaksma
RVRiemer J.K. Vegter
Riemer J.K. Vegter
MLMarika T. Leving
Marika T. Leving
JSJan W. van der Scheer
Jan W. van der Scheer
MTMarga Tepper
Marga Tepper
SGSonja de Groot
Sonja de Groot
Objective: The aim of this study was to compare handrim wheelchair propulsion technique between individuals with spinal cord injury with and without shoulder pain. Design: A cross-sectional study including 38 experienced handrim wheelchair users with spinal cord injury was conducted. Participants were divided into the “shoulder pain” (n = 15) and “no-shoulder pain” (n = 23) groups using the Local Musculoskeletal Discomfort scale. Kinetic and spatiotemporal aspects of handrim wheelchair propulsion during submaximal exercise on a motor-driven treadmill were analyzed. Data were collected using a measurement wheel instrumented with three-dimensional force sensors. Results: After correction for confounders (time since injury and body height), linear regression analyses showed that the pain group had a 0.30-sec (95% confidence interval, −0.5 to −0.1) shorter cycle time, 0.22-sec (95% confidence interval, −0.4 to −0.1) shorter recovery time, 15.6 degrees (95% confidence interval, −27.4 to −3.8) smaller contact angle, and 8% (95% confidence interval, −15 to 0) lower variability in work per push compared with the no-pain group. Other parameters did not differ between groups. Conclusions: This study indicates that individuals with spinal cord injury who experience shoulder pain propel their handrim wheelchair kinematically differently from individuals with spinal cord injury without shoulder pain. This difference in propulsion technique might be a pain-avoiding mechanism aimed at decreasing shoulder range of motion.

1 January 2006
Verified
Conference Paper
Open access
SWShouYi Wang
ShouYi Wang
JBJelmer Braaksma
Jelmer Braaksma
RBR. Babuska
R. Babuska
DHD. Hobbelen
D. Hobbelen
Biped robots based on the concept of (passive) dynamic walking are far simpler than the traditional fullyI controlled walking robots, while achieving a more natural gait and consuming less energy. However, lightly actuated dynamic walking robots, which rely on the natural limit cycle of their mechanical structure, are very sensitive to ground disturbances. Already a very small step down can cause the robot to lose stability. In this paper, we investigate the use of reinforcement learning to make a dynamic walking robot more robust against ground disturbances. The learning controller is applied to a simulated two-link biped which is an abstraction of a mechanical prototype developed at the Delft Biorobotics Laboratory. The learning controller has been designed such that it can be applied as a straightforward extension of the proportionalI-derivative (PD) controller currently used to drive the robot's pneumatic actuators. The learning controller is therefore suitable for the future implementation in the robot hardware. Simulation results demonstrate that the biped quickly learns to overcome step-down disturbances on the floor up to 10% of the leg length, without compromising the natural walking style provided by the PD controller, which was optimized for walking on an even surface.

10 June 2025 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
EFEnrico Ferlinghetti
Enrico Ferlinghetti
JBJelmer Braaksma
Jelmer Braaksma
TRThomas Rietveld
Thomas Rietveld
HHHan Houdijk
Han Houdijk
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
The objective of this study is to compare the error in detecting the start and end times of hand-wheel contact during wheelchair propulsion using two marker-less vision systems: ASD and MLVS. The first system, based on angular speed difference (ASD), relies only on the difference in angular speed between the hand and the wheel, calculated from RGB videos collected at 240 Hz. The angular speed of the hand was assessed using MediaPipe, a marker-less detection system, while the angular speed of the wheel was computed using a visual encoder operating on coloured tape positioned on the wheel and hand-rim in two configurations: hexagonal and incremental. The second system, MLVS, uses RGB-depth videos collected at 60 Hz and incorporates additional parameters, such as radial distance and normal position, to evaluate contact. The reference for contact initiation and termination was obtained from the torque signal collected on an instrumented wheelchair ergometer, with subsequent corrections made through expert visual inspection of video recordings. Data were collected from two participants who propelled a wheelchair on a wheelchair ergometer at 1.11 m/s and 0.21 W/kg body mass. Various thresholds for the angular speed difference between the hand and the wheel were tested, and the root mean square error (RMSE) for contact initiation and termination times was evaluated. The results showed that the lowest RMSE obtained with ASD was approximately 155 ms, while the RMSE obtained with MLVS were approximately 90 ms for contact initiation and 60 ms for contact termination, comparable to what was obtained with MLVS in previous studies. Accordingly, the study concludes that using only the relative angular speed between hand and hand-rim is not a reliable predictor of contact initiation or termination within the assessed experimental setup.

25 June 2024 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Open access
JBJelmer Braaksma
Jelmer Braaksma
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
HHHan Houdijk
Han Houdijk
SGSonja De Groot
Sonja De Groot
In the Netherlands, around 150.000 persons with reduced lower-limb function depend on a manual wheelchair for their daily mobility [1]. Wheelchairs should fulfill the needs and goals of the person ...

9 July 2024 in Actuators
Verified
Journal Article
Open access
PDF file
JBJelmer Braaksma
Jelmer Braaksma
EFEnrico Ferlinghetti
Enrico Ferlinghetti
SGSonja De Groot
Sonja De Groot
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
HHHan Houdijk
Han Houdijk
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
To examine the biomechanical demands of manual wheelchair propulsion, it is crucial to determine the wheelchair user’s (WCU) force for propulsion technique parameter calculation. When using a pushrim-activated power-assisted wheelchair (PAPAW) on a wheelchair ergometer, a combined propulsion force from the WCU and PAPAW is exerted. To understand PAPAW’s assistance and distinguish the WCU’s force application from the force exerted by the PAPAW, both propulsion components must be assessed separately. In this study, a calibration of the PAPAW on an ergometer was developed to achieve this separation. The calibration consists of five steps: (I) Collecting data on force and velocity measured from the ergometer, along with electrical current and velocity from the PAPAW. (II) Synchronizing the velocity signals of the wheelchair ergometer and PAPAW using cross-correlation. (III) Calibrating the PAPAW’s electromotors to convert electrical current (mA) to force (N). A product-specific motor constant of 0.30, provided an average ICC of 0.563, indicating a moderate agreement between the raw ergometer data (N) and the motor constant-converted drive-rim (PAPAW) data (from mA to N). (IV) Subtracting the PAPAW’s force signal from the ergometer’s measured force to isolate forces generated by the WCU. (V) Using markerless motion capture to determine and validate the phase of hand contact with the handrim. This technical note provides an example of PAPAW calibration for researchers and clinicians. It emphasizes the importance of integrating this calibration into the development of PAPAW devices to reveal the complex interaction between PAPAW and WCU during wheelchair propulsion.

26 June 2024
Verified
Conference Paper
Closed access
EFEnrico Ferlinghetti
Enrico Ferlinghetti
JBJelmer Braaksma
Jelmer Braaksma
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
This study evaluates the performance of a marker-less vision system to measure the start and the end of the hand contact phase during wheelchair propulsion. The system is composed by Mediapipe, a software that recognizes the hand on the RGB images and a classifier that determines whether the hand is in contact with the hand-rim for each frame. The system was validated with 17 subjects that propelled a wheelchair placed on a wheelchair ergometer at three different speeds (4 km/h, equal to 1.11 m/s, 5.4 km/h, equal to 1.5 m/s and maximal sprint) while holding a tennis racket or with free hands. The system, using data coming from RGB images only or combined with depth information, measured the start and end of the contact with a standard uncertainty of 55 ms. This value was comparable to 50 ms, obtained in a previous study using depth images 1]. This study also explains the implementation of three different reliability scores, aiming to evaluate the number of frames in which Mediapipe did not recognize the hand and the likelihood of each data point being classified as “contact” or “no-contact”. These scores showed a weak correlation with the error in contact detection.