Enrico Ferlinghetti

Enrico Ferlinghetti

Auto-generated profile, based on publicly available information

Enrico Ferlinghetti

DIMI, Università degli Studi di Brescia, Brescia, Italy & Department of Human Movement Sciences, University Medical Center Groningen, University of Groningen, The Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
EFEnrico Ferlinghetti
Enrico Ferlinghetti
ISInge Salzmann
Inge Salzmann
Marco GhidelliMarco Ghidelli
Marco Ghidelli
TRThomas Rietveld
Thomas Rietveld
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
This study investigates the reliability of marker-less vision systems for contact detection between hand and hand-rim during wheelchair propulsion. The measurement system uses a camera collecting RGB and depth images. The hand is detected through Mediapipe, a software able to recognize the key points of the hand on the RGB image. Hand position is expressed with respect to the wheel. A classifier is used to determine if there is contact between hand and hand-rim. To validate this procedure, 17 able-bodied participants pushed the wheelchair on an ergometer during six tests, given by the combinations of holding a tennis racket in their right hand while propelling at three different speeds: 4 km/h, 5.4 km/h and maximal sprint. Since validated contact detection methods are lacking in literature, experts provided a reference by manually evaluating video recordings and force signals frame-by-frame. The results showed that the hand identification by Mediapipe is not influenced by the presence of the racket but by the speed. Contact events were detected in the 99.5% of the cases. The mean error in contact time detection was -5 ms for the starts and 18 ms for the ends, the standard deviation was 48 ms for both and the combined root mean square error (RMSE) was 48 ms for the starts and 50 ms for the ends. These values, once corrected the systematic effects, lead to a standard uncertainty of approximately 0.05 s, corresponding to 15 % of the average contact duration. The study highlights the potential use of marker-less vision systems for contact detection in wheelchair propulsion.

10 June 2025 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
EFEnrico Ferlinghetti
Enrico Ferlinghetti
JBJelmer Braaksma
Jelmer Braaksma
TRThomas Rietveld
Thomas Rietveld
HHHan Houdijk
Han Houdijk
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
The objective of this study is to compare the error in detecting the start and end times of hand-wheel contact during wheelchair propulsion using two marker-less vision systems: ASD and MLVS. The first system, based on angular speed difference (ASD), relies only on the difference in angular speed between the hand and the wheel, calculated from RGB videos collected at 240 Hz. The angular speed of the hand was assessed using MediaPipe, a marker-less detection system, while the angular speed of the wheel was computed using a visual encoder operating on coloured tape positioned on the wheel and hand-rim in two configurations: hexagonal and incremental. The second system, MLVS, uses RGB-depth videos collected at 60 Hz and incorporates additional parameters, such as radial distance and normal position, to evaluate contact. The reference for contact initiation and termination was obtained from the torque signal collected on an instrumented wheelchair ergometer, with subsequent corrections made through expert visual inspection of video recordings. Data were collected from two participants who propelled a wheelchair on a wheelchair ergometer at 1.11 m/s and 0.21 W/kg body mass. Various thresholds for the angular speed difference between the hand and the wheel were tested, and the root mean square error (RMSE) for contact initiation and termination times was evaluated. The results showed that the lowest RMSE obtained with ASD was approximately 155 ms, while the RMSE obtained with MLVS were approximately 90 ms for contact initiation and 60 ms for contact termination, comparable to what was obtained with MLVS in previous studies. Accordingly, the study concludes that using only the relative angular speed between hand and hand-rim is not a reliable predictor of contact initiation or termination within the assessed experimental setup.

9 July 2024 in Actuators
Verified
Journal Article
Open access
PDF file
JBJelmer Braaksma
Jelmer Braaksma
EFEnrico Ferlinghetti
Enrico Ferlinghetti
SGSonja De Groot
Sonja De Groot
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
HHHan Houdijk
Han Houdijk
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
To examine the biomechanical demands of manual wheelchair propulsion, it is crucial to determine the wheelchair user’s (WCU) force for propulsion technique parameter calculation. When using a pushrim-activated power-assisted wheelchair (PAPAW) on a wheelchair ergometer, a combined propulsion force from the WCU and PAPAW is exerted. To understand PAPAW’s assistance and distinguish the WCU’s force application from the force exerted by the PAPAW, both propulsion components must be assessed separately. In this study, a calibration of the PAPAW on an ergometer was developed to achieve this separation. The calibration consists of five steps: (I) Collecting data on force and velocity measured from the ergometer, along with electrical current and velocity from the PAPAW. (II) Synchronizing the velocity signals of the wheelchair ergometer and PAPAW using cross-correlation. (III) Calibrating the PAPAW’s electromotors to convert electrical current (mA) to force (N). A product-specific motor constant of 0.30, provided an average ICC of 0.563, indicating a moderate agreement between the raw ergometer data (N) and the motor constant-converted drive-rim (PAPAW) data (from mA to N). (IV) Subtracting the PAPAW’s force signal from the ergometer’s measured force to isolate forces generated by the WCU. (V) Using markerless motion capture to determine and validate the phase of hand contact with the handrim. This technical note provides an example of PAPAW calibration for researchers and clinicians. It emphasizes the importance of integrating this calibration into the development of PAPAW devices to reveal the complex interaction between PAPAW and WCU during wheelchair propulsion.

26 June 2024
Verified
Conference Paper
Closed access
EFEnrico Ferlinghetti
Enrico Ferlinghetti
JBJelmer Braaksma
Jelmer Braaksma
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
This study evaluates the performance of a marker-less vision system to measure the start and the end of the hand contact phase during wheelchair propulsion. The system is composed by Mediapipe, a software that recognizes the hand on the RGB images and a classifier that determines whether the hand is in contact with the hand-rim for each frame. The system was validated with 17 subjects that propelled a wheelchair placed on a wheelchair ergometer at three different speeds (4 km/h, equal to 1.11 m/s, 5.4 km/h, equal to 1.5 m/s and maximal sprint) while holding a tennis racket or with free hands. The system, using data coming from RGB images only or combined with depth information, measured the start and end of the contact with a standard uncertainty of 55 ms. This value was comparable to 50 ms, obtained in a previous study using depth images 1]. This study also explains the implementation of three different reliability scores, aiming to evaluate the number of frames in which Mediapipe did not recognize the hand and the likelihood of each data point being classified as “contact” or “no-contact”. These scores showed a weak correlation with the error in contact detection.

14 January 2025 in Sports
Verified
Journal Article
Open access
PDF file
RKRyushi Kumamoto
Ryushi Kumamoto
PLPing Yeap Loh
Ping Yeap Loh
Yuqi HeYuqi He
Yuqi He
EFEnrico Ferlinghetti
Enrico Ferlinghetti
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
TUTadashi Uno
Tadashi Uno
Physical inactivity is a major global public health concern, and table tennis offers a low-impact, engaging way to promote physical activity across various age groups. However, many beginners struggle to maintain effective participation due to their lower skill levels. Therefore, the development and reinforcement of stable grip techniques is crucial because it will help beginners achieve sustainable improvements in performance. This will provide additional opportunities to increase physical activity, and therefore overall health, across all age groups. Thus, in this study, we investigate the effects of a prototype table tennis handle on the racket angle and performance of beginners. The prototype handle features a 20° tilt to assist the player in maintaining a stable topspin forehand grip during play. The participants were randomized into three groups, Groups A, B, and C, which used the prototype handle, standard handle, and practiced with the prototype but performed tests with the standard handle, respectively. The participants executed topspin forehand strokes in approximately 30 min of practice, and data on racket angles, swing mechanics, success rates, and ball landing positions were collected. The results showed that Group A exhibited a larger racket open angle and a smaller racket face Angle than the other groups. However, the groups showed no significant differences in hit positions or overall success rates. Our results suggest that although the prototype handle can influence racket angles and some performance aspects, individual differences and swing mechanics should be considered.

28 May 2025
Verified
Conference Paper
Closed access
EFEnrico Ferlinghetti
Enrico Ferlinghetti
JBJelmer Braaksma
Jelmer Braaksma
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
HHHan Houdijk
Han Houdijk
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
Marker-Less Vision System (MLVS) is a system that detects the start and the end of the contact phase between hand and hand-rim during wheelchair propulsion. It uses a camera to collect RGB and depth images, which are processed by MediaPipe, a software to identify hand keypoints, while a classifier determines contact on a frame-by-frame basis using the relative position between the hand and hand-rim in real-world coordinates. Previously, MLVS was trained and metrologically validated on stationary wheelchair ergometer data. This study extends its application to dynamic conditions by assessing its performance during treadmill-based wheelchair propulsion, where relative motion between the camera and wheelchair occurs. Six non-disabled participants propelled a wheelchair on a treadmill, and MLVS-detected contact initiation and termination times were compared to a reference obtained via manual annotation based on torque measurements and video inspection. The root mean square error (RMSE) was $1.9^{*}10^{2}$ ms for contact initiation and for contact termination, corresponding to approximately half the duration of an average contact duration of 350 ms. These results highlight the challenges introduced by relative motion and suggest potential areas for improvement in MLVS for dynamic propulsion scenarios.