Objective . Newer cone-beam computed tomography (CBCT) imaging systems offer reconstruction algorithms including metal artifact reduction (MAR) and extended field-of-view (eFoV) techniques to improve image quality. In this study a new CBCT imager, the new Varian HyperSight CBCT, is compared to fan-beam CT and two CBCT imagers installed in a ring-gantry and C-arm linear accelerator, respectively. Approach . The image quality was assessed for HyperSight CBCT which uses new hardware, including a large-size flat panel detector, and improved image reconstruction algorithms. The decrease of metal artifacts was quantified (structural similarity index measure (SSIM) and root-mean-squared error (RMSE)) when applying MAR reconstruction and iterative reconstruction for a dental and spine region using a head-and-neck phantom. The geometry and CT number accuracy of the eFoV reconstruction was evaluated outside the standard field-of-view (sFoV) on a large 3D-printed chest phantom. Phantom size dependency of CT numbers was evaluated on three cylindrical phantoms of increasing diameter. Signal-to-noise and contrast-to-noise were quantified on an abdominal phantom. Main results . In phantoms with streak artifacts, MAR showed comparable results for HyperSight CBCT and CT, with MAR increasing the SSIM (0.97–0.99) and decreasing the RMSE (62–55 HU) compared to iterative reconstruction without MAR. In addition, HyperSight CBCT showed better geometrical accuracy in the eFoV than CT (Jaccard Conformity Index increase of 0.02–0.03). However, the CT number accuracy outside the sFoV was lower than for CT. The maximum CT number variation between different phantom sizes was lower for the HyperSight CBCT imager (∼100 HU) compared to the two other CBCT imagers (∼200 HU), but not fully comparable to CT (∼50 HU). Significance . This study demonstrated the imaging performance of the new HyperSight CBCT imager and the potential of applying this CBCT system in more advanced scenarios by comparing the quality against fan-beam CT.
Osteoradionecrosis (ORN) is a severe late complication after radiotherapy but current knowledge on ORN risks in the setting of postoperative radiotherapy (PORT) is limited. We studied the incidence and risk factors of ORN in patients with oral cavity cancers (OCC, treated with PORT. A retrospective cohort study was conducted including OCC patients (mainly squamous cell) treated with postoperative intensity modulated radiotherapy between 2010 and 2018 with > 1 year disease-free survival. Cumulative incidences of ORN were computed using the Kaplan Meier method. Clinical and dosimetric risk factors for mandibular ORN were evaluated using Cox regression models. Within our cohort (N = 227, median follow-up 49 months) we observed 46 cases of ORN, mainly in the mandible (n = 41). The cumulative incidence of mandibular ORN was 15.9 % (SE 2.5 %) at three years and 19.8 % (SE 3.0 %) at five years. At univariable analysis, smoking, mandibular mandibulotomy or segment resection, mean dose to the mandible, and mandible volume (%) ≥ 60 Gy (V60) were significantly associated with increased ORN risks. At multivariable analysis, smoking (HR 2.13, 95 %CI 1.12-4.06) and V60 (HR 1.02 per 1 % increase, 95 %CI 1.01-1.04) remained predictive factors. For active smokers with a high V60 ≥ 40 % we observed rapid ORN development with a 1-year incidence of 29 % vs 6 % for others (p < 0.01). OCC Patients treated with PORT are at high risk for mandibular ORN. We identified the mandibular volume receiving ≥ 60 Gy as the dominant risk factor, especially in active smokers. Limiting high-dose volumes at treatment planning may decrease ORN risks.