Verónica Rodríguez-Saldaña

Dr. Verónica Rodríguez-Saldaña

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2023 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Open access
VRVerónica Rodríguez-Saldaña
Verónica Rodríguez-Saldaña
CGCésar Castro García
César Castro García
Rogelio Rodríguez-MaeseRogelio Rodríguez-Maese
Rogelio Rodríguez-Maese
LLLuz O. Leal-Quezada
Luz O. Leal-Quezada

11 June 2024 in Water
Verified
Journal Article
Open access
PDF file
Rogelio Rodríguez-MaeseRogelio Rodríguez-Maese
Rogelio Rodríguez-Maese
VRVerónica Rodríguez-Saldaña
Verónica Rodríguez-Saldaña
Laura FerrerLaura Ferrer
Laura Ferrer
LLLuz O. Leal
Luz O. Leal
Manganese is considered an emerging pollutant and it is perceived as a potential threat to human health and aquatic ecosystems. The need to determine and monitor the presence of Mn in environmental water requires increasingly precise and accurate chemical analytical techniques that provide reliable information to take timely measures in the event of potential environmental contingencies. The automation by flow analysis technique has allowed analytical procedures to isolate and preconcentrate manganese in environmental water samples. Additionally, it brings forth benefits such as greatly enhancing the sample processing capacity and a reduced time and reagent usage, leading to cost savings and minimized waste production, thereby aligning with the principles of green chemistry. In this review, a recent report of some flow analysis techniques (FIA, rFIA, SIA, MSFIA, LOV, and MPFS) is presented, highlighting the trend of automation, whose portability and miniaturization allow for complete in situ analysis. There are two remarkable analytical features from the studies evaluated here, which are sample throughput and accuracy, with a maximum processing time of 120 samples h−1 and an accuracy of 98%. The implementation of flow analysis techniques offers several advantages, such as miniaturization and portability. The discussed methodologies achieved limits of quantification as low as 0.26 µg L−1, enabling environmental monitoring that can easily detect the reference value of 0.05 mg L−1, established by the WHO and the EPA.


19 November 2018 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
VRVerónica Rodríguez-Saldaña
Verónica Rodríguez-Saldaña
FGFernando González-Farías
Fernando González-Farías
SMSilvia Violeta Miranda-Navarro
Silvia Violeta Miranda-Navarro

17 February 2026 in Water
Verified
Journal Article
Open access
PDF file
VRVerónica Rodríguez-Saldaña
Verónica Rodríguez-Saldaña
CGCésar Castro García
César Castro García
JDJennifer Mabel Luna Díaz
Jennifer Mabel Luna Díaz
Rogelio Rodríguez-MaeseRogelio Rodríguez-Maese
Rogelio Rodríguez-Maese
LLLuz O. Leal
Luz O. Leal
Ibuprofen (IBU), paracetamol (PARA), and diclofenac (DIC) are three of the most used non-opioid analgesics and are most frequently detected in the environment. Some methods to analyze these compounds in water have been previously reported, but they have limitations such as long analysis time, high reagent consumption, and lack of sensitivity. An electrospray ionization high-performance liquid chromatography–mass spectrometry (ESI-HPLC-MS/MS)-based method was developed for the determination of these analgesics, applying 3D printing to improve the extraction process. The method was validated and applied to quantify the target pharmaceuticals using commercial tablets. For PARA and DIC, a gradient elution with 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) was employed. For the analysis of IBU, an isocratic elution with 10 mM acetate in water (A) and acetonitrile (B) was used. ESI-MS/MS spectra were obtained in positive polarity to identify DIC and PARA, while negative polarity was used for IBU. LOD were 40.91, 3.64, and 1.96, and the LOQ were 136.36, 12.15, and 6.52 ng/L for IBU, PARA, and DIC, respectively. R2 was >0.99 and RSD < 10% in all cases. The 3D-printed extraction device can be used for up to 10 cycles. This method demonstrated a remarkable performance compared to previous studies, mainly in terms of precision (RSD = 0.6–4.16%), mobile phase consumption (4 mL), and analysis time (<7 min), and was applied in the analysis of surface water samples.

15 February 2025 in Water
Verified
Journal Article
Open access
PDF file
Rogelio Rodríguez-MaeseRogelio Rodríguez-Maese
Rogelio Rodríguez-Maese
VRVerónica Rodríguez-Saldaña
Verónica Rodríguez-Saldaña
LLLuz O. Leal
Luz O. Leal
Lead (Pb) is one of the most relevant contaminants due to its high toxicity, even at low concentrations. The growing need for research about real-time Pb analysis in the field has driven advancements in portable, sensitive, and automated analytical methodologies. These innovations are crucial for taking proactive measures against the impacts of Pb pollution on ecosystems and public health. Flow analysis techniques have proven to be very effective in automating procedures for isolating and preconcentrating Pb in surface water and biological samples. Such automation boosts sample throughput and reduces processing time and reagent consumption, aligning with the green chemistry principles by lowering costs and minimizing waste. This review covers 31 recent automated analytical methodologies employing flow analysis techniques such as FIA, SIA, MSFIA, and LOV, emphasizing the trend toward portability and miniaturization, which facilitates in-situ analysis. Additionally, this review examines the pretreatment methods and detection systems used, highlighting the analytical parameters of each technique. The methodologies discussed demonstrate the capability to process up to 55 samples per hour accurately. Limits of quantification as low as 0.014 µg L−1 are reported, enabling environmental monitoring that effectively detects Pb concentrations below the WHO and EPA drinking water reference values of 10 µg L−1 and 15 µg L−1, respectively.