The acoustic temperature measurement method has a broad application prospect due to its advantages of high precision, non-contact, etc. It is expected to become a new method for hidden fire source detection in mines. The acoustic time of flight (TOF) can directly affect the accuracy of acoustic temperature measurement. We proposed a quadratic correlation-based phase transform weighting (PHAT-β) algorithm for estimating the time delay of the acoustic temperature measurement of a loose coal. Validation was performed using an independently built experimental system for acoustic temperature measurement of loose coals under multi-factor coupling. The results show that the PHAT-β algorithm estimated acoustic TOF values closest to the reference line as the sound travelling distance increased. The results of coal temperature inversion experiments show that the absolute error of the PHAT-β algorithm never exceeds 1 °C, with a maximum value of 0.862 °C. Using the ROTH weighted error maximum, when the particle of the coal samples is 3.0–5.0 cm, the absolute error maximum is 4.896 °C, which is a difference of 3.693 °C from the error minimum of 1.203 °C in this particle size interval. The accuracy of six algorithms was ranked as PHAT-β > GCC > PHAT > SCOT > HB > ROTH, further validating the accuracy and reliability of the PHAT-β algorithm.
26 December 2024 in Alexandria Engineering Journal
The measurement error of sound travel time, one of the most critical parameters in acoustic temperature measurement, is significantly affected by the type of sound source signal. In order to select more appropriate sound source signals, a sound source signal preference study of loose coal acoustic temperature measurement was performed and is described herein. The results showed that the absolute error of the swept signal and the pseudo-random signal both increased with increased acoustic wave propagation distance. The relative error of the swept signal showed a relatively stable upward trend; in comparison, the pseudo-random signal showed a general decrease with a large fluctuation in the middle section, and both the relative and absolute errors for the pseudo-random signal were larger than those of the swept signal. Therefore, the swept signal is expected to perform better than the pseudo-random signal in the loose coal medium. Based on the experimental results, the linear sweep signal was selected as the sound source signal for the loose coal temperature inversion experiments: the average error between the inverted temperature value and the actual value was 4.86%, the maximum temperature difference was 2.926 °C, and the average temperature difference was 1.5949 °C.