A photonic-assisted scheme based on optical frequency shift heterodyne and low-frequency power mapping is proposed and experimentally demonstrated to measure the Doppler frequency shift (DFS) and Angle-of-arrival (AOA) of the microwave signals. In the proposed system, the optical signal is divided into two paths. The upper optical signal is injected into a dual-drive Mach-Zehnder modulator (DDMZM) and modulated by the two echo signals with a phase difference. The lower path optical signal is frequency-shifted by an acousto-optic modulator (AOM) and then modulated by the transmitted signal via a Mach-Zehnder modulator (MZM). After an optical filter, the two first-order sideband optical signals heterodyne in the photodetector. The DFS without direction ambiguity and AOA are mapped to the frequency shift and power of the low-frequency microwave signal. By adjusting the DC bias of the DDMZM, two power-phase mapping curves are obtained to eliminate phase ambiguity in AOA measurement. The measurement accuracy is enhanced by adjusting the identity of the two power mapping curves in different measurement ranges. A proof-of-concept experiment demonstrates a DFS measurement at 20 GHz with errors less than ± 8 Hz in the range of ±100 kHz and an AOA measurement from −62.5° to 62.5° with no more than ±2.5° errors.
28 December 2022 in IEEE Photonics Technology Letters
This letter proposes a simple method for measuring frequency responses of photodetectors (PDs) based on the multiple harmonic responses of a direct-modulated laser (DML). This method provides numerous harmonics as carriers for subsequent Mach–Zehnder modulator (MZM) modulation based on the nonlinear effect of the direct modulation laser. The modulated signal is injected into the photodetector under test, and the frequency response of the photodetector detector is obtained by sampling the MZM modulation component around multiple harmonics on the electronics spectrum analyzer (ESA). By measuring the relative amplitude of the modulation components around different harmonics, measurement error caused by harmonic amplitude differences can be eliminated. This method greatly expands the measurement range of the frequency response from DC to 2nfm. Moreover, since the modulator modulation frequency range occupies only $\frac {1}{2{\mathrm {n}}}$ of the entire measurement range, the uneven frequency response caused by the modulator is reduced, and extra calibration is avoided. According to this method, we use a 35GHz Mach-Zehnder modulator to measure the frequency response of photodetectors with the bandwidth of 35GHz and 50GHz, respectively. We also compared our method with those conventional methods, and the results show that the method which has a wide frequency response can accurately measure the frequency response of the PD under the condition of the method.
In this paper, a compact ambient gas sensor with an optimized photoacoustic cell is reported. The relationship between the geometric dimensions (usually radius and length) of the photoacoustic cell (PAC) and the acoustic signal was studied through theoretical and finite element analysis. Then an optimized H-type PAC with a volume of 80 mm × 30 mm × 30 mm was machined out. The gas capacity is only 18.85 millilitres. The performance of the photoacoustic cell has been verified experimentally by the detection of nitrogen dioxide () standard gas. With an electret microphone and an economically self-designed 450 nm laser module, the detection of concentration was executed. The experimental results show good linearity with a fitting R-square of 0.9991. With an SNR (signal-to-noise ratio) of 41.247, the minimum detection limit (MDL) of the system can reach 4.85 ppb (1). With an analysis of allan variance, the MDL can achieve 0.11 ppb with a 228 s integration time. By replacing the light source, the system shows great potential for sensitive and compact detectors for other ambient gasses as well.
5 March 2025 in IEEE Transactions on Instrumentation and Measurement
The multimode thru-reflect-line (TRL) algorithm is widely used for on-wafer differential circuit calibration. This paper presents the design and calibration of coplanar grounded waveguide (GCPW) based calibration kits. Based on the original algorithm, we optimise the reflect standard symbol determination algorithm. The impedance transformation algorithm is added so that the algorithm can be applied to calibrating strongly coupled devices. An improved algorithm and the designed calibration kits enabled precise calibration from 0.1 GHz to 110 GHz. The conventional multimode TRL algorithm line standards have a narrow calibration range and require manual selection. In this paper, an algorithm for selecting line standards is proposed, which automatically selects line standards with minor errors and expands the calibration frequency of line standards. Finally, the error of the improved multimode TRL algorithm is quantitatively analysed and discussed.
We report a scheme to measure the broadband frequency response of photodetectors (PDs) with the capacity of self-calibration. The optical carrier at is modulated through one modulator, and this modulator is driven by a microwave signal with a fixed frequency to produce the carrier-suppressed double sideband optical signals and . The frequency interval of the optical signals is . Subsequently, the two optical signals are sent to another modulator driven by a swept microwave signal . Two pairs of carrier-suppressed double sideband signals with a high signal-to-noise ratio are generated. The frequencies of these signals are , , and . After the PD under test, the frequency response can be extracted from the amplitude of the microwave signals at , , and . Two PDs in our laboratory are experimentally characterized from 0.1 to 40 GHz with a resolution of 100 MHz. Compared with the traditional vector network analyzer swept method, the proposed method extends the measurement range from to and has the capacity of self-calibration to eliminate the influence caused by the modulator frequency response on the measurement results.
A transmission line(TL) impedance transformer of through-hole (TO)-CAN distributed feedback (DFB) laser is proposed and fabricated. The gain and noise factor(NF) of analog optical link can be improved by optimizing the laser impedance matching network. The radio frequency(RF) package of DFB is optimized to extend bandwidth and reduce return loss. In this paper, a flexible printed circuit(FPC) with low-loss impedance matching network is designed to improved the RF characteristics of TO-CAN DFB laser. The return path between FPC and TO-CAN is optimized to eliminate microwave resonances. The small signal model of an analog optical link is analyzed in detail. The measured frequency response of the TO-CAN DFB is 18.4 GHz. The microwave reflection is below -10 dB. The measured results correlates perfectly with the simulated results. The gain of analog optical link is increased by 3 dB. The NF is also reduced by about 2.5 dB.