Photoacoustic (PA) imaging has become invaluable in preclinical and clinical research. Endoscopic PA imaging in particular has been explored as a noninvasive imaging modality to view vasculature and diagnose cancers in the digestive system. However, these feasibility studies are still limited to rodents or rabbits. Here, we develop a fully synchronized simultaneous ultrasound and photoacoustic microscopy system using two spectral bands (i.e., the visible and near-infrared) in both optical- and acoustic-resolution modes. We investigate the feasibility of imaging gastric vasculature in an ex vivo porcine model. The entire gastric wall, including the mucosa, submucosa, muscularis propria, and serosa, was excised from fresh porcine stomachs immediately followed by ultrasound and PA imaging being performed within a few hours of sacrifice. PA images of the mucosal vasculature were obtained at depths of 1.90 mm, which is a clinically significant accomplishment considering that the average thickness of the human mucosa is 1.26 mm. The layer structure of the stomach wall could be clearly distinguished in the overlaid PA and US images. Because gastric cancer starts from the mucosal surface and infiltrates into the submucosa, PA imaging can cover a clinically relevant depth in early gastric cancer diagnosis. We were able to detect mucosal vasculature in the entire mucosal layer, suggesting the potential utility of combined PA/US imaging in gastroenterology.
Excellent research in the fields of medicine and medical science can advance the field and contribute to human health improvement. In this aspect, research is important. However, if researchers do not publish their research, their efforts cannot benefit anyone. To make a difference, researchers must disseminate their results and communicate their opinions. One way to do this is by publishing their research. Therefore, academic writing is an essential skill for researchers. However, preparing a manuscript is not an easy task, and it is difficult to write well. Following a structure may be helpful for researchers. For example, the standard structure of medical and medical science articles includes the following sections: introduction, methods, results, and discussion (IMRAD). The purpose of this review is to present an introduction for researchers, especially novices, on how to write an original article in the field of medicine and medical science. Therefore, we discuss how to prepare and write a research manuscript for publication, using the IMRAD structure. We also included specific tips for writing manuscripts in medicine and medical science.
With the growing prevalence of plastic use, the environmental release of plastic waste is escalating, and fragmented nanoscale plastic particles are emerging as significant environmental threats. This study aimed to evaluate the cytotoxic effects of fragmented polyethylene nanoplastics (PE NPs) manufactured using a focused ultrasonic system. The ultrasonic irradiation process generated fragmented PE NPs with a geometric mean diameter of 85.14 ± 5.37 nm and a size range of 25-350 nm. To assess cytotoxicity, we conducted a series of tests on various human cell lines, including stomach, blood, colon, lung, skin, liver, and brain-derived cells. The testing involved MTS-based cell viability assays to evaluate direct impacts on cell viability, lactate dehydrogenase (LDH) leakage assays to measure membrane damage, and ELISA to quantify TNF-α release as an indicator of inflammation. Although PE-NPs did not immediately induce apoptosis, significant LDH leakage and elevated TNF-α levels were observed across all cell lines, indicating membrane damage and inflammatory responses. Additionally, flow cytometry and TEM analyses revealed the intracellular accumulation of PE-NPs, further supporting their cytotoxic potential. These results demonstrate that fragmented PE-NPs can disrupt cellular membranes and induce inflammatory responses through accumulation within cells. The findings suggest that these NPs pose potential hazards to cell viability and underscore the need for further research into their environmental and health impacts.
1 March 2014 in The Journal of the Acoustical Society of America
A shock pressure pulse used in an extracorporeal shock wave treatment has a large negative pressure (<-5 MPa) which can produce cavitation. Cavitation cannot be measured easily, but may have known therapeutic effects. This study considers the signal recorded for several hundred microseconds using an optical hydrophone submerged in water at the focus of shock pressure field. The signal is characterized by shock pulse followed by a long tail after several microseconds; this signal is regarded as a cavitation-related signal (CRS). An experimental investigation of the CRS was conducted in the shock pressure field produced in water using an optical hydrophone (FOPH2000, RP Acoustics, Germany). The CRS was found to contain characteristic information about the shock pulse-induced cavitation. The first and second collapse times (t1 and t2) were identified in the CRS. The collapse time delay (tc = t2 - t1) increased with the driving shock pressures. The signal amplitude integrated for time from t1 to t2 was highly correlated with tc (adjusted R(2) = 0.990). This finding suggests that a single optical hydrophone can be used to measure shock pulse and to characterize shock pulse-induced cavitation.
The aim of this experimental study was to evaluate whether the acoustic radiation force (ARF) is a potential source of twinkling artifacts in color Doppler images. Color Doppler images were obtained using a clinical ultrasonic scanner (Voluson e, GE Healthcare) for a high contrast (+15 dB) circular scattering phantom at pulse repetition frequencies (PRFs) ranging from 0.1 to 13 kHz. Ultrasound transmissions resulting in ARF were measured using a hydrophone at the various PRFs considered. The influence of ARF on the appearance of twinkling colors was examined via the common parameter PRF. This methodology is based on the fact that alternating positive and negative Doppler shifts induced by the ARF are centered at a PRF twice the maximum Doppler frequency on the color scale bar, whereas the twinkling color aliasing is expected to remain similar regardless of PRF. Color twinkling artifacts were observed to be most conspicuous at the lowest PRF of 0.1 kHz. The extent of twinkling rapidly decreased as the PRF increased, eventually disappearing when the PRF ≥0.6 kHz. The measured ultrasound transmissions, however, were found to be insensitive to the PRF, and therefore it can be inferred that the PRF was insensitive to the ARF. Based on our experimental observations, the ARF may not be a source of color Doppler twinkling artifacts.
Background and objectives: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are the two most commonly used coronary indices of physiological stenosis severity based on pressure. To minimize the effect of wedge pressure (Pwedge), FFR is measured during hyperemia conditions, and iFR is calculated as the ratio of distal and aortic pressures (Pd/Pa) in the wave-free period. The goal of this study was to predict Pwedge using the backward wave (Pback) through wave separation analysis (WSA) and to reflect the effect of Pwedge on FFR and iFR to identify the relationship between the two indices. Methods: An in vitro circulation system was constructed to calculate Pwedge. The measurements were performed in cases with stenosis percentages of 48, 71, and 88% and with hydrostatic pressures of 10 and 30 mmHg. Then, the correlation between Pback by WSA and Pwedge was calculated. In vivo coronary flow and pressure were simultaneously measured for 11 vessels in all patients. The FFR and iFR values were reconstructed as the ratios of forward wave at distal and proximal sites during hyperemia and at rest, respectively. Results: Based on the in vitro results, the correlation between Pback and Pwedge was high (r = 0.990, p < 0.0001). In vivo results showed high correlations between FFR and reconstructed FFR (r = 0.992, p < 0.001) and between iFR and reconstructed iFR (r = 0.930, p < 0.001). Conclusions: Reconstructed FFR and iFR were in good agreement with conventional FFR and iFR. FFR and iFR can be expressed as the variation of trans-stenotic forward pressure, indicating that the two values are inferred from the same formula under different conditions.