Demand for devices that allow the self-assessment of blood pressure continues to rise. Few self-assessment devices, however, have been validated against recognised protocols. The aim of this study was to validate the Omron MX3 Plus (model HEM-742-E) oscillometric blood pressure measuring device in accordance with the international protocol of the European Society of Hypertension. This automated device is currently available to the public in the UK through high-street chemists and other outlets. The European Society of Hypertension's international protocol for validation of blood pressure measuring devices in adults divides validation into two phases. The first phase is performed on 15 individuals, five in each of three specific blood pressure categories. If the device passes the first phase then a further 18 patients are recruited, making a total of 33 individuals on which the final validation is based. All subjects are aged 30 years or above. The automated device was connected in parallel to two reference mercury sphygmomanometers. Nine sequential same-arm measurements were taken from each subject by two trained observers, alternating between the mercury sphygmomanometers and the test device. The Omron MX3 Plus passed both phases of the ESH validation process. The mean (standard deviation) of the difference between the observer and the device measurements was −1.15 (5.7) mmHg for systolic and −1.61 (4.7) mmHg for diastolic pressures, respectively. The Omron MX3 Plus can be recommended for home and professional use in an adult population.
Optical coherence tomography (OCT) has been shown to be of clinical value in imaging basal cell carcinoma (BCC). A novel dual OCT-video imaging system, providing automated registration of OCT and dermoscopy, has been developed to assess the potential of OCT in measuring the degree of sub-clinical spread of BCC. Seventeen patients selected for Mohs micrographic surgery (MMS) for BCC were recruited to the study. The extent of BCC infiltration beyond a segment of the clinically assessed pre-surgical border was evaluated using OCT. Sufficiently accurate (2.5 mm. In addition, the OCT border lay between 0.5 mm and 2.0 mm inside the final MMS defect in those cases where this could be assessed. In one case, where the final MMS defect was over 17 mm from the clinical border, OCT showed >2.5 mm infiltration across the clinical border at the FOV limit. These results provide evidence that OCT allows more accurate assessment of sub-clinical spread of BCC than clinical observation alone. Such a capability may have clinical value in reducing the number of surgical stages in MMS for BCC. There may also be a role for OCT in aiding the selection of patients most suitable for MMS.
1 March 2014 in The Journal of the Acoustical Society of America
A shock pressure pulse used in an extracorporeal shock wave treatment has a large negative pressure (<-5 MPa) which can produce cavitation. Cavitation cannot be measured easily, but may have known therapeutic effects. This study considers the signal recorded for several hundred microseconds using an optical hydrophone submerged in water at the focus of shock pressure field. The signal is characterized by shock pulse followed by a long tail after several microseconds; this signal is regarded as a cavitation-related signal (CRS). An experimental investigation of the CRS was conducted in the shock pressure field produced in water using an optical hydrophone (FOPH2000, RP Acoustics, Germany). The CRS was found to contain characteristic information about the shock pulse-induced cavitation. The first and second collapse times (t1 and t2) were identified in the CRS. The collapse time delay (tc = t2 - t1) increased with the driving shock pressures. The signal amplitude integrated for time from t1 to t2 was highly correlated with tc (adjusted R(2) = 0.990). This finding suggests that a single optical hydrophone can be used to measure shock pulse and to characterize shock pulse-induced cavitation.
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Skin cancer is the most common type of cancer in the UK, with over 100,000 cases diagnosed each year. Melanoma is a type of skin cancer that can develop from a mole. However, moles that are suspicious histologically are often difficult to diagnose clinically by eye, even for experts working in specialist skin cancer screening clinics. In the UK, 350,000 patients per year are referred to hospital clinics with suspicious moles, and approximately half undergo a biopsy to identify the 5-10% who require further treatment. If cancer cannot be ruled out clinically and on the basis of biopsy results, the lesion is surgically removed. One type of pre-cancerous mole, called lentigo maligna, is particularly challenging to treat. It develops insidiously, can become large, and is difficult to assess when it transforms into a lentigo maligna melanoma. It is also difficult to identify the margins by eye or with the aid of a dermatoscope. This results in high excision rates. Excision is often incomplete despite large areas of tissue removal (5 mm around tumour’s visible margin), and there are high recurrence rates even when the lesion is considered successfully removed. Reflectance confocal microscopy is an imaging technique that can supplement dermoscopy in identifying if a clinically suspicious mole is malignant and can better assess lentigo maligna margins. It allows clinicians to see the skin lesion in greater detail than dermoscopy and therefore better guide more accurate diagnoses. This prospective study will examine patients with suspicious moles and lentigo maligna to determine whether confocal microscopy can both reduce the number of unnecessary biopsies of moles and more accurately guide the surgical excision margins of lentigo maligna.
24 August 2020 in Biomedical Physics & Engineering Express
A novel model of the skin dose in whole-body UV phototherapy treatment cabins is presented. The model is based on an analysis of the thermal radiation exchange between two surfaces, in this case the UV source and the patient. It is shown to allow analytical treatment of the multiple internal reflections in a treatment cabin that account for around 40% of the skin irradiance. The model provides predictions of the absolute irradiance at the skin and shielding factors in seven different UVA and NB-UVB cabins that are within 6% of those measured using a calibrated radiometer and within 12% for all nine cabins. The model predicts reducing skin irradiances with increasingly patient size, a trend demonstrated in clinical measurements. The exact sensitivity to patient size in automated cabin dosimetry systems, however, varies with in-built sensor positioning. The potential to extend the use of the model to investigate improved design of automated dosimetry systems is discussed.