Craig S. Levin

Dr. Craig S. Levin


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2017 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
DHDavid F.C. Hsu
David F.C. Hsu
EIEzgi Ilan
Ezgi Ilan
WPWilliam T. Peterson
William T. Peterson
JUJorge Uribe
Jorge Uribe
MLMark Lubberink
Mark Lubberink
CLCraig S. Levin
Craig S. Levin
This article presents system performance studies of the Discovery MI PET/CT system, a new time-of-flight (TOF) system based on silicon photomultipliers. System performance and clinical imaging comparisons were made between this next-generation system and other commercially available PET/CT and PET/MR systems, as well as between different reconstruction algorithms. Methods: Spatial resolution, sensitivity, NECR, scatter fraction, count rate accuracy, and image quality were characterized with the NEMA NU-2 2012 standards. Energy and coincidence time resolution were measured. Tests were conducted independently and results were averaged on two Discovery MI scanners installed at Stanford and Uppsala University Hospitals. Back-to-back patient scans were also performed between the Discovery MI PET/CT, Discovery 690 PET/CT, and SIGNA PET/MR systems. Clinical images were reconstructed with both ordered-subset expectation maximization (OSEM) and the "Q.Clear" reconstruction algorithms, and examined qualitatively. Results: The averaged full-width half max (FWHM) of the radial/tangential/axial spatial resolution reconstructed with FBP at 1, 10, and 20 cm from the system center are, respectively, 4.10/4.19/4.48 mm, 5.47/4.49/6.01 mm, and 7.53/4.90/6.10 mm. The averaged sensitivity is 13.7 cps/kBq at the center of the FOV. Averaged peak noise equivalent count rate is 193.4 kcps at 21.9 kBq/mL with a scatter fraction of 40.6%. The averaged contrast recovery coefficients for the image quality phantom are 53.7/64.0/73.1/82.7/86.8/90.7 for the 10/13/17/22/28/37 mm diameter spheres. The average photopeak energy resolution is 9.40% FWHM and the average coincidence time resolution is 375.4 ps FWHM. Clinical image comparisons between the PET/CT systems demonstrate the high quality of the Discovery MI system. Comparisons between the Discovery MI and SIGNA systems show similar spatial resolution and overall imaging performance. Lastly, results indicate significant image quality and contrast-to-noise performance enhancement for the "Q.Clear" reconstruction algorithm when compared to OSEM. Conclusion: Excellent performance was achieved with the new Discovery MI system, including 375 ps FWHM coincidence time resolution and sensitivity of 14 cps/kBq. Comparisons between different image reconstruction algorithms and other multimodal SiPM and non-SiPM-based PET detector system designs indicate substantial performance enhancements are possible with this next-generation system.

13 April 2016 in Medical Physics
Verified
Journal Article
Open access
AGAlexander M. Grant
Alexander M. Grant
TDTimothy W. Deller
Timothy W. Deller
MKMohammad Mehdi Khalighi
Mohammad Mehdi Khalighi
SMSri Harsha Maramraju
Sri Harsha Maramraju
GDGaspar Delso
Gaspar Delso
CLCraig S. Levin
Craig S. Levin
Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

12 February 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
AGAntonio J. Gonzalez
Antonio J. Gonzalez
SPShirin Pourashraf
Shirin Pourashraf
RMRobert S. Miyaoka
Robert S. Miyaoka
PBPeter Bruyndonckx
Peter Bruyndonckx
CLCraig S. Levin
Craig S. Levin
The use of monolithic scintillator-based photon detectors in positron emission tomography (PET) has emerged as an attractive alternative to traditional pixelated array designs. Monolithic-based detector designs employ the scintillation light distribution (LD) shape to provide a single 3D photon interaction position per event, enabling high spatial resolution throughout the crystal volume. Since there are no intercrystal gaps, monolithic designs provide higher intrinsic detection efficiency compared to pixelated designs. However, in order to make the monolithic detector design practical for clinical PET systems, some major drawbacks need to be addressed such as the timeconsuming and complex calibration procedures to obtain precise spatial and timing information. This paper gives a historical review of monolithic-based PET detectors, a description of their main advantages and challenges, describes the state-of-the-art, including their use in current commercial system, and ends with a future prospective.

3 October 2008 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GPGuillem Pratx
Guillem Pratx
GCGarry Chinn
Garry Chinn
POPeter D. Olcott
Peter D. Olcott
CLCraig S. Levin
Craig S. Levin
List-mode processing provides an efficient way to deal with sparse projections in iterative image reconstruction for emission tomography. An issue often reported is the tremendous amount of computation required by such algorithm. Each recorded event requires several back- and forward line projections. We investigated the use of the programmable graphics processing unit (GPU) to accelerate the line-projection operations and implement fully-3D list-mode ordered-subsets expectation-maximization for positron emission tomography (PET). We designed a reconstruction approach that incorporates resolution kernels, which model the spatially-varying physical processes associated with photon emission, transport and detection. Our development is particularly suitable for applications where the projection data is sparse, such as high-resolution, dynamic, and time-of-flight PET reconstruction. The GPU approach runs more than 50 times faster than an equivalent CPU implementation while image quality and accuracy are virtually identical. This paper describes in details how the GPU can be used to accelerate the line projection operations, even when the lines-of-response have arbitrary endpoint locations and shift-varying resolution kernels are used. A quantitative evaluation is included to validate the correctness of this new approach.

1 September 2010 in Current Pharmaceutical Biotechnology
Verified
Journal Article
Closed access
PDF file
HPHao Peng
Hao Peng
CLCraig S. Levin
Craig S. Levin
Positron emission tomography (PET) is used in the clinic and in vivo small animal research to study molecular processes associated with diseases such as cancer, heart disease, and neurological disorders, and to guide the discovery and development of new treatments. This paper reviews current challenges of advancing PET technology and some of newly developed PET detectors and systems. The paper focuses on four aspects of PET instrumentation: high photon detection sensitivity; improved spatial resolution; depth-of-interaction (DOI) resolution and time-of-flight (TOF). Improved system geometry, novel non-scintillator based detectors, and tapered scintillation crystal arrays are able to enhance the photon detection sensitivity of a PET system. Several challenges for achieving high resolution with standard scintillatorbased PET detectors are discussed. Novel detectors with 3-D positioning capability have great potential to be deployed in PET for achieving spatial resolution better than 1 mm, such as cadmium-zinc-telluride (CZT) and position-sensitive avalanche photodiodes (PSAPDs). DOI capability enables a PET system to mitigate parallax error and achieve uniform spatial resolution across the field-of-view (FOV). Six common DOI designs, as well as advantages and limitations of each design, are discussed. The availability of fast scintillation crystals such as LaBr3, and the silicon photomultiplier (SiPM) greatly advances TOF-PET development. Recent instrumentation and initial results of clinical trials are briefly presented. If successful, these technology advances, together with new probe molecules, will substantially enhance the molecular sensitivity of PET and thus increase its role in preclinical and clinical research as well as evaluating and managing disease in the clinic.

18 November 2010 in Sensors
Verified
Journal Article
Open access
PDF file
VSVirginia Spanoudaki
Virginia Spanoudaki
CLCraig S. Levin
Craig S. Levin
We present the most recent advances in photo-detector design employed in time of flight positron emission tomography (ToF-PET). PET is a molecular imaging modality that collects pairs of coincident (temporally correlated) annihilation photons emitted from the patient body. The annihilation photon detector typically comprises a scintillation crystal coupled to a fast photo-detector. ToF information provides better localization of the annihilation event along the line formed by each detector pair, resulting in an overall improvement in signal to noise ratio (SNR) of the reconstructed image. Apart from the demand for high luminosity and fast decay time of the scintillation crystal, proper design and selection of the photo-detector and methods for arrival time pick-off are a prerequisite for achieving excellent time resolution required for ToF-PET. We review the two types of photo-detectors used in ToF-PET: photomultiplier tubes (PMTs) and silicon photo-multipliers (SiPMs) with a special focus on SiPMs.