Guillem Pratx

Dr. Guillem Pratx

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2011 in Medical Physics
Verified
Journal Article
Open access
PDF file
GPGuillem Pratx
Guillem Pratx
LXLei Xing
Lei Xing
The graphics processing unit (GPU) has emerged as a competitive platform for computing massively parallel problems. Many computing applications in medical physics can be formulated as data‐parallel tasks that exploit the capabilities of the GPU for reducing processing times. The authors review the basic principles of GPU computing as well as the main performance optimization techniques, and survey existing applications in three areas of medical physics, namely image reconstruction, dose calculation and treatment plan optimization, and image processing.

1 September 2018 in Biomaterials
Verified
Journal Article
Closed access
KJKyung Oh Jung
Kyung Oh Jung
HJHunho Jo
Hunho Jo
JYJung Ho Yu
Jung Ho Yu
SGSanjiv Sam Gambhir
Sanjiv Sam Gambhir
GPGuillem Pratx
Guillem Pratx

1 September 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
GPGuillem Pratx
Guillem Pratx
DKDaniel S Kapp
Daniel S Kapp
Recent results from animal irradiation studies have demonstrated the potential of ultra-high dose rate irradiation (also known as FLASH) for reducing radiation toxicity in normal tissues. However, despite mounting evidence of a ‘FLASH effect’, a mechanism has yet to be elucidated. This article hypothesizes that the radioprotecting effect of FLASH irradiation could be due to the specific sparing of hypoxic stem cell niches, which have been identified in several organs including the bone marrow and the brain. To explore this hypothesis, a new computational model is presented that frames transient radiolytic oxygen depletion (ROD) during FLASH irradiation in terms of its effect on the oxygen enhancement ratio (OER). The model takes into consideration oxygen diffusion through the tissue, its consumption by metabolic cells, and its radiolytic depletion to estimate the relative decrease in radiosensitivity of cells receiving FLASH irradiation. Based on this model and the following parameters (oxygen diffusion constant = 2 · 10 −5 cm 2 s −1 , oxygen metabolic rate m = 3 mmHg s −1 , ROD rate L ROD = mmHg Gy −1 , prescribed dose D p = 10 Gy, and capillary oxygen tension p 0 = 40 mmHg), several predictions are made that could be tested in future experiments: (1) the FLASH effect should gradually disappear as the radiation pulse duration is increased from <1 s to 10 s; (2) dose should be deposited using the smallest number of radiation pulses to achieve the greatest FLASH effect; (3) a FLASH effect should only be observed in cells that are already hypoxic at the time of irradiation; and (4) changes in capillary oxygen tension (increase or decrease) should diminish the FLASH effect.

8 July 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GPGuillem Pratx
Guillem Pratx
CCColin M. Carpenter
Colin M. Carpenter
CSConroy Sun
Conroy Sun
Lei XingLei Xing
Lei Xing
X-ray luminescence computed tomography (XLCT) is proposed as a new molecular imaging modality based on the selective excitation and optical detection of X-ray-excitable phosphor nanoparticles. These nano-sized particles can be fabricated to emit near-infrared (NIR) light when excited with X-rays, and, because because both X-rays and NIR photons propagate long distances in tissue, they are particularly well suited for in vivo biomedical imaging. In XLCT, tomographic images are generated by irradiating the subject using a sequence of programmed X-ray beams, while sensitive photo-detectors measure the light diffusing out of the subject. By restricting the X-ray excitation to a single, narrow beam of radiation, the origin of the optical photons can be inferred regardless of where these photons were detected, and how many times they scattered in tissue. This study presents computer simulations exploring the feasibility of imaging small objects with XLCT, such as research animals. The accumulation of 50 nm phosphor nanoparticles in a 2-mm-diameter target can be detected and quantified with subpicomolar sensitivity using less than 1 cGy of radiation dose. Provided sufficient signal-to-noise ratio, the spatial resolution of the system can be made as high as needed by narrowing the beam aperture. In particular, 1 mm spatial resolution was achieved for a 1-mm-wide X-ray beam. By including an X-ray detector in the system, anatomical imaging is performed simultaneously with molecular imaging via standard X-ray computed tomography (CT). The molecular and anatomical images are spatially and temporally co-registered, and, if a single-pixel X-ray detector is used, they have matching spatial resolution.

8 December 2014 in Nano Letters
Verified
Journal Article
Open access
DNDominik Jan Naczynski
Dominik Jan Naczynski
CSConroy Sun
Conroy Sun
STSilvan Türkcan
Silvan Türkcan
CJCesare Jenkins
Cesare Jenkins
AKAi Leen Koh
Ai Leen Koh
Lei XingLei Xing
Lei Xing
Shortwave infrared (SWIR or NIR-II) light provides significant advantages for imaging biological structures due to reduced autofluorescence and photon scattering. Here, we report on the development of rare-earth nanoprobes that exhibit SWIR luminescence following X-ray irradiation. We demonstrate the ability of X-ray-induced SWIR luminescence (X-IR) to monitor biodistribution and map lymphatic drainage. Our results indicate X-IR imaging is a promising new modality for preclinical applications and has potential for dual-modality molecular disease imaging.

8 October 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
GPGuillem Pratx
Guillem Pratx
CCColin M. Carpenter
Colin M. Carpenter
CSConroy Sun
Conroy Sun
RRRavi P. Rao
Ravi P. Rao
Lei XingLei Xing
Lei Xing
X-ray luminescence computed tomography (XLCT) is proposed as a new dual molecular/anatomical imaging modality. XLCT is based on the selective excitation and optical detection of x-ray-excitable nanoparticles. As a proof of concept, we built a prototype XLCT system and imaged near-IR-emitting Gd2O2S:Eu phosphors in various phantoms. Imaging in an optically diffusive medium shows that imaging performance is not affected by optical scatter; furthermore, the linear response of the reconstructed images suggests that XLCT is capable of quantitative imaging.