In this article, a PZT/Epoxy 1-3 piezoelectric composite based on picosecond laser etching technology is developed for the fabrication of high-frequency ultrasonic transducer. The design, fabrication, theoretical analysis, and performance of the piezocomposite and transducer are presented and discussed. According to the test results, the area of the PZT pillar is 20.5 μm × 20.5 μm, the average width of the kerf is 4.5 μm, and the thickness of the piezocomposite is 38 μm. The fabricated 1-3 piezocomposite has a resonant frequency of 46.5 MHz, a parallel resonant frequency of 65 MHz, and an electromechanical coupling coefficient of 0.73. According to the wires phantom imaging, its imaging resolution can reach 50 μm. This study shows that the proposed picosecond laser micromachining technique can be applied in the fabrication of high frequency 1-3 piezocomposite and transducer.
Due to the small aperture of blood vessel, a considerable disadvantage to current intravascular ultrasound (IVUS) imaging transducers is that their lateral imaging resolution is much lower than their axial resolution. To solve this problem, a single-element, 50 MHz, 0.6 mm diameter IVUS transducer with a geometric focus at 3 mm was proposed in this paper. The focusing transducer was based on a geometric-shaped 1-3 piezocomposite. The impedance/phase, pulse echo, acoustic intensity field, and imaging resolution of the focusing transducer were tested. For comparison, a flat IVUS transducer with the same diameter and 1-3 piezocomposite was made and tested too. Compared with their results, the fabricated focusing transducer exhibits broad bandwidth (107.21%), high sensitivity (404 mV), high axial imaging resolution (80 μm), and lateral imaging resolution (100 μm). The experimental results demonstrated that the high frequency geometric focusing piezocomposite transducer is capable of visualizing high axial and lateral resolution structure and improving the imaging quality of related interventional ultrasound imaging.
13 July 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Chirp coded excitation is an effective method to improve the signal-to-noise ratio (SNR) and penetration depth of high-frequency endoscopic ultrasound (EUS) imaging. In coded excitation, pulse compression is applied to compress the elongated coded signals into a short pulse, which determines the final imaging performance, including spatial resolution and SNR. However, with the current pulse compression methods, it is hard to get high performance in the peak sidelobe level (PSL), image contrast, and axial resolution at the same time. To solve this problem, in this article, a new method named compressed pulse weighting method (CPWM) was proposed based on the combination of two kinds of pulse compression signals. A brief theoretical derivation proved the feasibility of method. The proposed method was evaluated by the simulation and phantom experiments. Compared with traditional method, the results showed that the proposed adaptive weighting method can provide increases of 32.42% in the penetration depth, 9.48 dB in the SNR, 5.60 dB in the contrast ratio (CR), 5.46 in the contrast-to-noise ratio (CNR), and 0.13 mm in the axial imaging resolution for 12-MHz EUS. Therefore, this method can effectively improve the ultrasound penetration depth and imaging quality, which made it have good potential for high-frequency ultrasound imaging.
High-speed mechanical rotation scanning is the main imaging method of current high-frequency internal ultrasound. Due to uneven drag on the catheter driveshaft leading to changes in the rotational speed, Nonuniform rotational deformity (NURD) is critically limited for the quantitative analysis of internal ultrasound use. To date there have been no techniques shown that provide effective and dynamic modulation of NURD. In this work, a micro structured high-frequency rotary ultrasonic encoder with cylinder gratings was developed, which can dynamically fix the NURD and get high quality restored image. Accordingly, a prototyped micro rotary 50-MHZ ultrasonic encoder with a miniature diameter of 3 mm and a selection of resolutions up to 64 pulses per revolution, which should be the smallest and highest frequency rotary ultrasonic encoder ever reported, was demonstrated based on an endoscopic ultrasound system. The miniature high-frequency rotary ultrasonic encoder shows great potential for ultrasonic endoscopy, OCT, and other mechanical scanning imaging.
The equivalent circuit simulation plays an important role in the design of ultrasound transducer. However, the existing methods are difficult to achieve the effect of matching and backing layer, and not able to accurately simulate the transducer with cable. Especially in the application of high frequency ultrasound, the long cable has a great influence on the performance of the transducer. To overcome these limitations, this paper proposed an improved equivalent circuit method, which combined Leach model and transmission line model. It can realize the complete simulation of ultrasound transducer with a long cable, matching layer, and backing layer in PSPICE circuit simulation software when the parameters were measured. Its principles were briefly introduced, and ultrasound transducers with different frequencies (12 and 20 MHz), different matching layers, and different cable lengths (0.5–2.5 m) were designed and fabricated to verify the effectiveness of the method, which is also compared with the traditional KLM method using PiezoCAD. The experiment results showed that the long cable, matching layer, and backing layer have a significant impact on the performance of high frequency ultrasound transducers, and this proposed method has good agreement with these results. Moreover, for the simulation of the complete transducer, the effect of this method is better than KLM model. Besides, this method does not need to know the specific equivalent circuit of matching, backing layer, or cable wire, it can accurately predict the impedance and phase of the transducer through the material parameters, which is very helpful for the material selection and optimization of subsequent transducer design and fabrication. The study indicates that this improved equivalent circuit method is suitable to be applied in the general circuit simulation software and provides strong support for the high frequency transducer and system design.